Assessing the impact of ventilation systems on indoor air quality: a mock-up experiment in Dubai

被引:3
作者
Jung, Chuloh [1 ]
El Samanoudy, Gamal [2 ]
Alqassimi, Nahla [3 ]
Sherzad, Mohammed [3 ]
机构
[1] Univ Sharjah, Coll Engn, Dept Architectural Engn, Sharjah, U Arab Emirates
[2] Ajman Univ, Coll Architecture Art & Design, Dept Interior Design, Ajman, U Arab Emirates
[3] Ajman Univ, Coll Architecture Art & Design, Dept Architecture, Ajman, U Arab Emirates
关键词
indoor air quality (IAQ); formaldehyde (HCHO); volatile organic compounds (VOCs); ventilation systems; mock-up experiment; BUILDINGS; CLIMATES;
D O I
10.3389/fbuil.2023.1286053
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor Air Quality (IAQ) has become an important concern in Dubai, driven by public health awareness, environmental regulations, and government initiatives. The Dubai Municipality has introduced guidelines and standards for IAQ in residential and non-residential buildings, emphasizing ventilation, material selection, and testing protocols. IAQ monitoring and testing are encouraged, and public awareness campaigns educate individuals about IAQ and its impact on health. Green building regulations in Dubai also address IAQ considerations. The Dubai Municipality has comprehensively assessed IAQ in public buildings, leading to stringent regulations. However, research on IAQ improvement and challenges associated with apartment ventilation systems is limited. This study aims to evaluate the IAQ improvement and potential issues of a ventilation system in an apartment through a mock-up experiment. Factors such as air volume, ventilation system type, and supply/exhaust duct configuration are analyzed. The results show that installing a ventilation device with a ventilation rate of 0.3-0.8 times/h reduces Formaldehyde (HCHO) and Volatile Organic Compounds (VOCs) concentrations by 30%-50%. The IAQ improvement is not significantly influenced by air volume. Each room supply/exhaust method shows a 10% higher reduction in VOC concentrations than the supply/kitchen exhaust unit method. Preventing backflow and addressing cold drafts are recommended during ventilation system installation. Noise measurements comply with standards in most cases. These findings contribute to developing guidelines for ventilation system design and installation in apartments, promoting healthier indoor environments. Further research with a broader range of ventilation devices and real-world conditions is recommended to validate these findings.
引用
收藏
页数:15
相关论文
共 50 条
[11]   An evaluation index for the control effect of the local ventilation systems on indoor air quality in industrial buildings [J].
Yi Wang ;
Yingxue Cao ;
Bo Liu ;
Jiaping Liu ;
Yang Yang ;
Qun Yu .
Building Simulation, 2016, 9 :669-676
[12]   An evaluation index for the control effect of the local ventilation systems on indoor air quality in industrial buildings [J].
Wang, Yi ;
Cao, Yingxue ;
Liu, Bo ;
Liu, Jiaping ;
Yang, Yang ;
Yu, Qun .
BUILDING SIMULATION, 2016, 9 (06) :669-676
[13]   Assessing Indoor Air Quality Using Chemometric Models [J].
Azid, Azman ;
Amran, Mohammad Azizi ;
Samsudin, Mohd Saiful ;
Abd Rani, Nurul Latiffah ;
Khalit, Saiful Iskandar ;
Gasim, Muhammad Barzani ;
Yunus, Kamaruzzaman ;
Saudi, Ahmad Shakir Mohd ;
Amin, Siti Noor Syuhada Muhammad ;
Yusof, Ku Mohd Kalkausar Ku .
POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2018, 27 (06) :2443-2450
[14]   Impact of displacement ventilation and underfloor air distribution systems on concentrations of indoor particle in different seasons [J].
Li, Linlin ;
Yao, Cheng ;
Liu, Wencheng ;
Yin, Zuohong ;
Huang, Weifang ;
Yao, Yifeng ;
Luo, Yang ;
Huang, Yuandong .
JOURNAL OF BUILDING ENGINEERING, 2024, 84
[15]   Associated relationship between ventilation rates and indoor air quality [J].
Cao, Shi-Jie ;
Zhu, Dong-Hao ;
Yang, Yin-Bao .
RSC ADVANCES, 2016, 6 (112) :111427-111435
[16]   Ventilation Strategies for Mitigating Indoor Air Pollutants in High-Rise Residential Buildings: A Case Study in Dubai [J].
Jung, Chuloh ;
Mahmoud, Naglaa Sami Abdelaziz .
ATMOSPHERE, 2023, 14 (11)
[17]   A review of integrated radiant heating/cooling with ventilation systems- Thermal comfort and indoor air quality [J].
Zhang, Chen ;
Pomianowski, Michal ;
Heiselberg, Per Kvols ;
Yu, Tao .
ENERGY AND BUILDINGS, 2020, 223
[18]   A NUMERICAL AND EXPERIMENTAL STUDY OF THE EFFECT OF USING PERSONAL VENTILATION SYSTEMS ON INDOOR AIR QUALITY IN OFFICE ROOMS [J].
Saheb, Hussien Aziz ;
Mahdi, Ala'a Abbas ;
Al-amir, Qusay Rasheed .
FRONTIERS IN HEAT AND MASS TRANSFER, 2021, 16
[19]   Inadequacy of air purifier for indoor air quality improvement in classrooms without external ventilation [J].
Choe, Youngtae ;
Shin, Jun-shup ;
Park, Jinhyeon ;
Kim, Eunchae ;
Oh, Narae ;
Min, Kihong ;
Kim, Dongjun ;
Sung, Kyunghwa ;
Cho, Mansu ;
Yang, Wonho .
BUILDING AND ENVIRONMENT, 2022, 207
[20]   A comprehensive analysis of the intervention of a fresh air ventilation system on indoor air quality in classrooms [J].
Chen, Yu-Hao ;
Tu, Yen-Pei ;
Sung, Shih-Yi ;
Weng, Wei-Cheng ;
Huang, Hsiao-Lin ;
Tsai, Ying, I .
ATMOSPHERIC POLLUTION RESEARCH, 2022, 13 (04)