Assessing the impact of ventilation systems on indoor air quality: a mock-up experiment in Dubai

被引:2
|
作者
Jung, Chuloh [1 ]
El Samanoudy, Gamal [2 ]
Alqassimi, Nahla [3 ]
Sherzad, Mohammed [3 ]
机构
[1] Univ Sharjah, Coll Engn, Dept Architectural Engn, Sharjah, U Arab Emirates
[2] Ajman Univ, Coll Architecture Art & Design, Dept Interior Design, Ajman, U Arab Emirates
[3] Ajman Univ, Coll Architecture Art & Design, Dept Architecture, Ajman, U Arab Emirates
关键词
indoor air quality (IAQ); formaldehyde (HCHO); volatile organic compounds (VOCs); ventilation systems; mock-up experiment; BUILDINGS; CLIMATES;
D O I
10.3389/fbuil.2023.1286053
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor Air Quality (IAQ) has become an important concern in Dubai, driven by public health awareness, environmental regulations, and government initiatives. The Dubai Municipality has introduced guidelines and standards for IAQ in residential and non-residential buildings, emphasizing ventilation, material selection, and testing protocols. IAQ monitoring and testing are encouraged, and public awareness campaigns educate individuals about IAQ and its impact on health. Green building regulations in Dubai also address IAQ considerations. The Dubai Municipality has comprehensively assessed IAQ in public buildings, leading to stringent regulations. However, research on IAQ improvement and challenges associated with apartment ventilation systems is limited. This study aims to evaluate the IAQ improvement and potential issues of a ventilation system in an apartment through a mock-up experiment. Factors such as air volume, ventilation system type, and supply/exhaust duct configuration are analyzed. The results show that installing a ventilation device with a ventilation rate of 0.3-0.8 times/h reduces Formaldehyde (HCHO) and Volatile Organic Compounds (VOCs) concentrations by 30%-50%. The IAQ improvement is not significantly influenced by air volume. Each room supply/exhaust method shows a 10% higher reduction in VOC concentrations than the supply/kitchen exhaust unit method. Preventing backflow and addressing cold drafts are recommended during ventilation system installation. Noise measurements comply with standards in most cases. These findings contribute to developing guidelines for ventilation system design and installation in apartments, promoting healthier indoor environments. Further research with a broader range of ventilation devices and real-world conditions is recommended to validate these findings.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Indoor Air Quality Management in Dubai: Assessing the Efficacy of Air Purifiers, Photocatalysts, and Window Ventilation in Reducing HCHO
    Jung, Chuloh
    Alshamasi, Shams Mohammed
    BUILDINGS, 2024, 14 (09)
  • [2] Assessing the impact of kitchen hoods and ventilation openings on indoor air quality post-cooking
    Chen, Shou-Wang
    Chang, Chao-Yen
    Chan, Ying-Chieh
    JOURNAL OF BUILDING ENGINEERING, 2025, 100
  • [3] Enhancing indoor air quality and sustainable living in newly constructed apartments: insights from Dubai
    Jung, Chuloh
    Mahmoud, Naglaa Sami Abdelaziz
    Alqassimi, Nahla
    FRONTIERS IN BUILT ENVIRONMENT, 2023, 9
  • [4] Numerical modelling for the interpretation of a laboratory mock-up experiment of bentonite/granite interface
    Yang, Q. C.
    Zhang, X.
    Liang, J.
    Yang, J. W.
    INTERNATIONAL CONFERENCE ON ECOLOGICAL INFORMATICS AND ECOSYSTEM CONSERVATION (ISEIS 2010), 2010, 2 : 713 - 719
  • [5] Indoor air quality in educational institutions: a comparative study of VOCs and bacterial contaminants in Dubai schools
    Jung, Chuloh
    El Samanoudy, Gamal
    Alqassimi, Nahla
    FRONTIERS IN BUILT ENVIRONMENT, 2024, 10
  • [6] Assessing ventilation strategies in a school with observed indoor air problems
    Uotila, Ulrika
    Saari, Arto
    Junnonen, Juha-Matti Kalevi
    Eskola, Lari
    FACILITIES, 2022, 40 (15-16) : 1 - 16
  • [7] Editorial - Ventilation and indoor air quality in residential dwellings
    Zhang, Tengfei
    Pei, Jingjing
    BUILDING AND ENVIRONMENT, 2019, 148 : 198 - 199
  • [8] Ventilation for good indoor air quality and energy efficiency
    Awbi, Hazim B.
    SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT, EENVIRO 2016, 2017, 112 : 277 - 286
  • [9] Optimizing Ventilation Systems in Barcelona Schools: An AHP-Based Assessment for Improved Indoor Air Quality and Comfort
    Lopez-Carreno, Ruben-Daniel
    Pujadas, Pablo
    Pardo-Bosch, Francesc
    APPLIED SCIENCES-BASEL, 2024, 14 (23):
  • [10] Evaluating the Indoor Air Quality after Renovation at the Greens in Dubai, United Arab Emirates
    Awad, Jihad
    Jung, Chuloh
    BUILDINGS, 2021, 11 (08)