A Novel Anthropomorphic Phantom Composed of Tissue-Equivalent Materials for Use in Experimental Radiotherapy: Design, Dosimetry and Biological Pilot Study

被引:6
作者
Breslin, Thomas [1 ]
Paino, Jason [2 ]
Wegner, Marie [3 ]
Engels, Elette [2 ,4 ]
Fiedler, Stefan [5 ]
Forrester, Helen [6 ]
Rennau, Hannes [7 ]
Bustillo, John [2 ]
Cameron, Matthew [4 ]
Hausermann, Daniel [4 ]
Hall, Christopher [4 ]
Krause, Dieter [3 ]
Hildebrandt, Guido [7 ]
Lerch, Michael [2 ]
Schueltke, Elisabeth [7 ]
机构
[1] Lund Univ, Dept Oncol, Clin Sci, S-22185 Lund, Sweden
[2] Univ Wollongong, Ctr Med Radiat Phys, Wollongong 2522, Australia
[3] Hamburg Univ Technol, Inst Prod Dev & Mech Engn Design, D-21073 Hamburg, Germany
[4] Australian Synchrotron ANSTO, Clayton 3168, Australia
[5] European Mol Biol Lab EMBL, Hamburg Outstat, D-22607 Hamburg, Germany
[6] Royal Melbourne Inst Technol RMIT Univ, Sch Sci, Melbourne 3001, Australia
[7] Rostock Univ Med Ctr, Dept Radiooncol, D-18059 Rostock, Germany
关键词
anthropomorphic phantom; CT scan; dosimetry; experimental radiotherapy; microbeam radiotherapy (MRT); tissue-equivalent materials; therapy planning;
D O I
10.3390/biomimetics8020230
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The production of anthropomorphic phantoms generated from tissue-equivalent materials is challenging but offers an excellent copy of the typical environment encountered in typical patients. High-quality dosimetry measurements and the correlation of the measured dose with the biological effects elicited by it are a prerequisite in preparation of clinical trials with novel radiotherapy approaches. We designed and produced a partial upper arm phantom from tissue-equivalent materials for use in experimental high-dose-rate radiotherapy. The phantom was compared to original patient data using density values and Hounsfield units obtained from CT scans. Dose simulations were conducted for broad-beam irradiation and microbeam radiotherapy (MRT) and compared to values measured in a synchrotron radiation experiment. Finally, we validated the phantom in a pilot experiment with human primary melanoma cells.
引用
收藏
页数:11
相关论文
共 15 条
  • [1] Medical physics aspects of the synchrotron radiation therapies: Microbeam radiation therapy (MRT) and synchrotron stereotactic radiotherapy (SSRT)
    Braeuer-Krisch, Elke
    Adam, Jean-Francois
    Alagoz, Enver
    Bartzsch, Stefan
    Crosbie, Jeff
    DeWagter, Carlos
    Dipuglia, Andrew
    Donzelli, Mattia
    Doran, Simon
    Fournier, Pauline
    Kalef-Ezra, John
    Kock, Angela
    Lerch, Michael
    McErlean, Ciara
    Oelfke, Uwe
    Olko, Pawel
    Petasecca, Marco
    Povoli, Marco
    Rosenfeld, Anatoly
    Siegbahn, Erik A.
    Sporea, Dan
    Stugu, Bjarne
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (06): : 568 - 583
  • [2] cirsinc, CIRS DYNAMIC THORAX
  • [3] X-Tream dosimetry of synchrotron radiation with the PTW microDiamond
    Davis, J. A.
    Petasecca, M.
    Cullen, A.
    Paino, J. R.
    Archer, J.
    Rosenfeld, A. B.
    Lerch, M. L. F.
    [J]. JOURNAL OF INSTRUMENTATION, 2019, 14 (10)
  • [4] Ultrahigh dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in mice
    Favaudon, Vincent
    Caplier, Laura
    Monceau, Virginie
    Pouzoulet, Frederic
    Sayarath, Mano
    Fouillade, Charles
    Poupon, Marie-France
    Brito, Isabel
    Hupe, Philippe
    Bourhis, Jean
    Hall, Janet
    Fontaine, Jean-Jacques
    Vozenin, Marie-Catherine
    [J]. SCIENCE TRANSLATIONAL MEDICINE, 2014, 6 (245)
  • [5] FLASH Irradiation Spares Lung Progenitor Cells and Limits the Incidence of Radio-induced Senescence
    Fouillade, Charles
    Curras-Alonso, Sandra
    Giuranno, Lorena
    Quelennec, Eddy
    Heinrich, Sophie
    Bonnet-Boissinot, Sarah
    Beddok, Arnaud
    Leboucher, Sophie
    Karakurt, Hamza Umut
    Bohec, Mylene
    Baulande, Sylvain
    Vooijs, Marc
    Verrelle, Pierre
    Dutreix, Marie
    Londono-Vallejo, Arturo
    Favaudon, Vincent
    [J]. CLINICAL CANCER RESEARCH, 2020, 26 (06) : 1497 - 1506
  • [6] Computed tomography tissue equivalence of 3D printing materials
    Jusufbegovic, M.
    Pandzic, A.
    Sehic, A.
    Jasic, R.
    Julardzija, F.
    Vegar-Zubovic, S.
    Beganovic, A.
    [J]. RADIOGRAPHY, 2022, 28 (03) : 788 - 792
  • [7] Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data
    Kiarashi, Nooshin
    Nolte, Adam C.
    Sturgeon, Gregory M.
    Segars, William P.
    Ghate, Sujata V.
    Nolte, Loren W.
    Samei, Ehsan
    Lo, Joseph Y.
    [J]. MEDICAL PHYSICS, 2015, 42 (07) : 4116 - 4126
  • [8] Characterization of a synthetic single crystal diamond detector for dosimetry in spatially fractionated synchrotron x-ray fields
    Livingstone, Jayde
    Stevenson, Andrew W.
    Butler, Duncan J.
    Hausermann, Daniel
    Adam, Jean-Francois
    [J]. MEDICAL PHYSICS, 2016, 43 (07) : 4283 - 4293
  • [9] Evaluation of a micro ionization chamber for dosimetric measurements in image-guided preclinical irradiation platforms
    Patallo, Ileana Silvestre
    Carter, Rebecca
    Maughan, David
    Nisbet, Andrew
    Schettino, Giuseppe
    Subiel, Anna
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (24)
  • [10] Microbeam radiation therapy - grid therapy and beyond: a clinical perspective
    Schuelke, Elisabeth
    Balosso, Jacques
    Breslin, Thomas
    Cavaletti, Guido
    Djonov, Valentin
    Esteve, Francois
    Grotzer, Michael
    Hildebrandt, Guido
    Valdman, Alexander
    Laissue, Jean
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1078)