A Novel Anthropomorphic Phantom Composed of Tissue-Equivalent Materials for Use in Experimental Radiotherapy: Design, Dosimetry and Biological Pilot Study

被引:9
作者
Breslin, Thomas [1 ]
Paino, Jason [2 ]
Wegner, Marie [3 ]
Engels, Elette [2 ,4 ]
Fiedler, Stefan [5 ]
Forrester, Helen [6 ]
Rennau, Hannes [7 ]
Bustillo, John [2 ]
Cameron, Matthew [4 ]
Hausermann, Daniel [4 ]
Hall, Christopher [4 ]
Krause, Dieter [3 ]
Hildebrandt, Guido [7 ]
Lerch, Michael [2 ]
Schueltke, Elisabeth [7 ]
机构
[1] Lund Univ, Dept Oncol, Clin Sci, S-22185 Lund, Sweden
[2] Univ Wollongong, Ctr Med Radiat Phys, Wollongong 2522, Australia
[3] Hamburg Univ Technol, Inst Prod Dev & Mech Engn Design, D-21073 Hamburg, Germany
[4] Australian Synchrotron ANSTO, Clayton 3168, Australia
[5] European Mol Biol Lab EMBL, Hamburg Outstat, D-22607 Hamburg, Germany
[6] Royal Melbourne Inst Technol RMIT Univ, Sch Sci, Melbourne 3001, Australia
[7] Rostock Univ Med Ctr, Dept Radiooncol, D-18059 Rostock, Germany
关键词
anthropomorphic phantom; CT scan; dosimetry; experimental radiotherapy; microbeam radiotherapy (MRT); tissue-equivalent materials; therapy planning;
D O I
10.3390/biomimetics8020230
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The production of anthropomorphic phantoms generated from tissue-equivalent materials is challenging but offers an excellent copy of the typical environment encountered in typical patients. High-quality dosimetry measurements and the correlation of the measured dose with the biological effects elicited by it are a prerequisite in preparation of clinical trials with novel radiotherapy approaches. We designed and produced a partial upper arm phantom from tissue-equivalent materials for use in experimental high-dose-rate radiotherapy. The phantom was compared to original patient data using density values and Hounsfield units obtained from CT scans. Dose simulations were conducted for broad-beam irradiation and microbeam radiotherapy (MRT) and compared to values measured in a synchrotron radiation experiment. Finally, we validated the phantom in a pilot experiment with human primary melanoma cells.
引用
收藏
页数:11
相关论文
共 15 条
[1]   Medical physics aspects of the synchrotron radiation therapies: Microbeam radiation therapy (MRT) and synchrotron stereotactic radiotherapy (SSRT) [J].
Braeuer-Krisch, Elke ;
Adam, Jean-Francois ;
Alagoz, Enver ;
Bartzsch, Stefan ;
Crosbie, Jeff ;
DeWagter, Carlos ;
Dipuglia, Andrew ;
Donzelli, Mattia ;
Doran, Simon ;
Fournier, Pauline ;
Kalef-Ezra, John ;
Kock, Angela ;
Lerch, Michael ;
McErlean, Ciara ;
Oelfke, Uwe ;
Olko, Pawel ;
Petasecca, Marco ;
Povoli, Marco ;
Rosenfeld, Anatoly ;
Siegbahn, Erik A. ;
Sporea, Dan ;
Stugu, Bjarne .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (06) :568-583
[2]  
cirsinc, CIRS DYNAMIC THORAX
[3]   X-Tream dosimetry of synchrotron radiation with the PTW microDiamond [J].
Davis, J. A. ;
Petasecca, M. ;
Cullen, A. ;
Paino, J. R. ;
Archer, J. ;
Rosenfeld, A. B. ;
Lerch, M. L. F. .
JOURNAL OF INSTRUMENTATION, 2019, 14 (10)
[4]   Ultrahigh dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in mice [J].
Favaudon, Vincent ;
Caplier, Laura ;
Monceau, Virginie ;
Pouzoulet, Frederic ;
Sayarath, Mano ;
Fouillade, Charles ;
Poupon, Marie-France ;
Brito, Isabel ;
Hupe, Philippe ;
Bourhis, Jean ;
Hall, Janet ;
Fontaine, Jean-Jacques ;
Vozenin, Marie-Catherine .
SCIENCE TRANSLATIONAL MEDICINE, 2014, 6 (245)
[5]   FLASH Irradiation Spares Lung Progenitor Cells and Limits the Incidence of Radio-induced Senescence [J].
Fouillade, Charles ;
Curras-Alonso, Sandra ;
Giuranno, Lorena ;
Quelennec, Eddy ;
Heinrich, Sophie ;
Bonnet-Boissinot, Sarah ;
Beddok, Arnaud ;
Leboucher, Sophie ;
Karakurt, Hamza Umut ;
Bohec, Mylene ;
Baulande, Sylvain ;
Vooijs, Marc ;
Verrelle, Pierre ;
Dutreix, Marie ;
Londono-Vallejo, Arturo ;
Favaudon, Vincent .
CLINICAL CANCER RESEARCH, 2020, 26 (06) :1497-1506
[6]   Computed tomography tissue equivalence of 3D printing materials [J].
Jusufbegovic, M. ;
Pandzic, A. ;
Sehic, A. ;
Jasic, R. ;
Julardzija, F. ;
Vegar-Zubovic, S. ;
Beganovic, A. .
RADIOGRAPHY, 2022, 28 (03) :788-792
[7]   Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data [J].
Kiarashi, Nooshin ;
Nolte, Adam C. ;
Sturgeon, Gregory M. ;
Segars, William P. ;
Ghate, Sujata V. ;
Nolte, Loren W. ;
Samei, Ehsan ;
Lo, Joseph Y. .
MEDICAL PHYSICS, 2015, 42 (07) :4116-4126
[8]   Characterization of a synthetic single crystal diamond detector for dosimetry in spatially fractionated synchrotron x-ray fields [J].
Livingstone, Jayde ;
Stevenson, Andrew W. ;
Butler, Duncan J. ;
Hausermann, Daniel ;
Adam, Jean-Francois .
MEDICAL PHYSICS, 2016, 43 (07) :4283-4293
[9]   Evaluation of a micro ionization chamber for dosimetric measurements in image-guided preclinical irradiation platforms [J].
Patallo, Ileana Silvestre ;
Carter, Rebecca ;
Maughan, David ;
Nisbet, Andrew ;
Schettino, Giuseppe ;
Subiel, Anna .
PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (24)
[10]   Microbeam radiation therapy - grid therapy and beyond: a clinical perspective [J].
Schuelke, Elisabeth ;
Balosso, Jacques ;
Breslin, Thomas ;
Cavaletti, Guido ;
Djonov, Valentin ;
Esteve, Francois ;
Grotzer, Michael ;
Hildebrandt, Guido ;
Valdman, Alexander ;
Laissue, Jean .
BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1078)