Global constructive work is associated with ventricular arrhythmias after cardiac resynchronization therapy

被引:0
|
作者
Saffi, Hillah [1 ]
Winslow, Ulrik [1 ]
Sakthivel, Tharsika [1 ]
Hojgaard, Emma Vinther [1 ]
Linde, Jesper [1 ]
Philbert, Berit [1 ]
Vinther, Michael [1 ]
Jons, Christian [1 ]
Bundgaard, Henning [1 ,2 ]
Risum, Niels [1 ]
机构
[1] Copenhagen Univ Hosp, Dept Cardiol, Rigshosp, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
[2] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
关键词
global constructive work; cardiac resynchronization therapy defibrillator; ventricular arrhythmias; speckle tracking; dyssynchrony; global longitudinal strain; SYMPTOMATIC HEART-FAILURE; MECHANICAL DYSSYNCHRONY; MYOCARDIAL STRAIN; RISK; MORTALITY; TRIAL;
D O I
10.1093/ehjci/jead180
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Non-invasive left ventricular (LV) pressure-strain loops provide a novel method for quantifying myocardial work by incorporating LV pressure in measurements of myocardial deformation. Early studies suggest that myocardial work parameters such as global constructive work (GCW) could be useful and reliable in arrhythmia prediction, particularly in patients undergoing cardiac resynchronization therapy (CRT). The aim of this study was to evaluate whether the magnitude of GCW was associated with the occurrence of ventricular arrhythmias in patients after CRT. Methods and results Patients on guideline-recommended treatment with a CRT defibrillator (CRT-D) were evaluated by 2D speckle-tracking echocardiography including measurements of GCW at least 6 months after implantation. The primary outcome was a composite of appropriate defibrillator therapy and sustained ventricular arrhythmia under the monitor zone. A total of 162 patients [mean age 66 years (+/- 10), 122 males (75%)] were included. Sixteen (10%) patients experienced the primary outcome during a median follow-up of 18 months (interquartile range: 12-25) after the performance of index echocardiography. Patients with a below-median GCW (<1473 mmHg%) had a hazard ratio (HR) for the outcome of 8.14 [95% confidence interval (CI): 1.83-36.08], P = 0.006 compared with patients above the median in a univariate model and remained an independent predictor after multivariate adjustment for the estimated glomerular filtration rate and QRS duration [HR 4.75 (95% CI: 1.01-22.28), P < 0.05]. Conclusion In patients treated with CRT-D, a GCW below median level was associated with a five-fold increase in the risk of ventricular arrhythmias.
引用
收藏
页码:29 / 36
页数:8
相关论文
共 50 条
  • [21] Association left ventricular lead and ventricular arrhythmias after upgrade to cardiac resynchronization therapy in patients with implantable cardioverter defibrillators
    Kawamura, Mitsuharu
    Arai, Shuhei
    Yoshikawa, Kosuke
    Gokan, Toshihiko
    Ogawa, Ko
    Ochi, Akinori
    Onishi, Yoshimi
    Munetsugu, Yumi
    Ito, Hiroyuki
    Onuki, Tatsuya
    Kobayashi, Youichi
    Shinke, Toshiro
    CLINICAL CARDIOLOGY, 2019, 42 (07) : 670 - 677
  • [22] QRS duration and QTc interval are predictors of risk for ventricular arrhythmias during cardiac resynchronization therapy
    Prochnau, Dirk
    Kuehnert, Helmut
    Figulla, Hans R.
    Surber, Ralf
    ACTA CARDIOLOGICA, 2011, 66 (04) : 415 - 420
  • [23] Implications of ventricular arrhythmia after cardiac resynchronization therapy
    Ueda, Nobuhiko
    Ishibashi, Kohei
    Noda, Takashi
    Oka, Satoshi
    Miyazaki, Yuichiro
    Shimamoto, Keiko
    Wakamiya, Akinori
    Nakajima, Kenzaburo
    Kamakura, Tsukasa
    Wada, Mitsuru
    Inoue, Yuko
    Miyamoto, Koji
    Nagase, Satoshi
    Aiba, Takeshi
    Kanzaki, Hideaki
    Izumi, Chisato
    Noguchi, Teruo
    Kusano, Kengo
    HEART RHYTHM, 2024, 21 (02) : 163 - 171
  • [24] Predicting Ventricular Arrhythmias in Cardiac Resynchronization Therapy: The Impact of Persistent Electrical Dyssynchrony
    Karaca, Oguz
    Gunes, Haci M.
    Omaygenc, Mehmet Onur
    Cakal, Beytullah
    Cakal, Sinem Deniz
    Demir, Gultekin Gunhan
    Kizilirmak, Filiz
    Gokdeniz, Tayyar
    Barutcu, Irfan
    Boztosun, Bilal
    Kilicaslan, Fethi
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2016, 39 (09): : 969 - 977
  • [25] Interaction of Left Ventricular Remodeling and Regional Dyssynchrony on Long-Term Prognosis after Cardiac Resynchronization Therapy
    Tayal, Bhupendar
    Sogaard, Peter
    Delgado-Montero, Antonia
    Goda, Akiko
    Saba, Samir
    Risum, Niels
    Gorcsan, John, III
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (03) : 244 - 250
  • [26] Amiodarone is associated with adverse outcomes in patients with sustained ventricular arrhythmias upgraded to cardiac resynchronization therapy-defibrillators
    Adelstein, Evan C.
    Althouse, Andrew D.
    Davis, Lydia
    Schwartzman, David
    Bazaz, Raveen
    Jain, Sandeep
    Wang, Norman
    Saba, Samir
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (03) : 348 - 356
  • [27] Right Ventricular Function Is a Determinant of Long-Term Survival after Cardiac Resynchronization Therapy
    Sade, Leyla Elif
    Ozin, Bulent
    Atar, Ilyas
    Demir, Ozlem
    Demirtas, Saadet
    Muderrisoglu, Haldun
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (07) : 706 - 713
  • [28] Risk of Ventricular Arrhythmias After Left Ventricular Function Improvement in Patients With Cardiac Resynchronization Therapy When Enough Is Not Enough COMMENT
    Birgersdotter-Green, Ulrika
    Lupercio, Florentino
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (10) : 1182 - 1184
  • [29] Integrated Proteomics and Metabolomics Analyses Reveal Molecular Mechanism of Cardiac Resynchronization Therapy Against Cardiac Fibrosis and Ventricular Arrhythmias
    Wu, Maoxiong
    Li, Haiying
    Tan, Jing
    Mai, Jingting
    Zheng, Shaoxin
    Qiu, Qiong
    Deng, Bingqing
    Lv, Hanlu
    Wang, Peiwei
    Wang, Jingfeng
    Chen, Yangxin
    Yuan, Woliang
    CARDIOVASCULAR TOXICOLOGY, 2025, 25 (05) : 762 - 777
  • [30] Atrial arrhythmias after cardiac resynchronization therapy: an inverse correlation with achieving 100% biventricular pacing and cardiac resynchronization therapy effectiveness
    Gasparini, Maurizio
    Cappelleri, Alessio
    EUROPACE, 2010, 12 (01): : 9 - 10