A four-dimensional dynamic conformal arc approach for real-time tumor tracking: A retrospective treatment planning study

被引:1
作者
Yau, Timothy [1 ,2 ]
Kempe, Jeff [2 ]
Gaede, Stewart [1 ,2 ,3 ]
机构
[1] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[2] London Hlth Sci Ctr, 800 Commissioners Rd E, London, ON N6A 5W9, Canada
[3] Lawson Hlth Res Inst, London, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
DCA; dose calculation; dynamic tumor tracking; respiratory management; VMAT; VOLUMETRIC-MODULATED ARC; STEREOTACTIC BODY RADIOTHERAPY; INSPIRATION BREATH-HOLD; RESPIRATORY MOTION; RADIATION-THERAPY; MLC TRACKING; LUNG; MANAGEMENT; IMPLEMENTATION; VALIDATION;
D O I
10.1002/acm2.14224
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: For many thoracic tumors, patient respiration can introduce a significant amount of variability in tumor position that must be accounted for during radiotherapy. Of all existing techniques, real-time dynamic tumor tracking (DTT) represents the most ideal motion management strategy but can be limited by the treatment delivery technique. Our objective was to analyze the dosimetric performance of a dynamic conformal arc (DCA) approach to tumor tracking on standard linear accelerators that may offer similar dosimetric benefit, but with less complexity compared to intensity-modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT).Methods: Ten patients who previously received free-breathing VMAT for lung cancer were retrospectively analyzed. Patient 4D-CT and respiratory traces were simultaneously acquired prior to treatment and re-planned with DCA and VMAT using the Eclipse v15.6 Treatment Planning System with gated, deep inspiration breath hold (DIBH), and motion encompassment techniques taken into consideration, generating seven new plans per patient. DTT with DCA was simulated using an in-house MATLAB script to parse the radiation dose into each phase of the 4D-CT based on the patient's respiratory trace. Dose distributions were normalized to the same prescription and analyzed using dose volume histograms (DVHs). DVH metrics were assessed using ANOVA with subsequent paired t-tests.Results: The DCA-based DTT plans outperformed or showed comparable performance in their DVH metrics compared to all other combinations of treatment techniques while using motion management in normal lung sparing (p < 0.05). Normal lung sparing was not significantly different when comparing DCA-based DTT to gated and DIBH VMAT (p > 0.05), while both outperformed the corresponding DCA plans (p < 0.05). Simulated treatment times using DCA-based DTT were significantly shorter than both gating and DIBH plans (p < 0.05).Conclusions: A DCA-based DTT technique showed significant advantages over conventional motion encompassment treatments in lung cancer radiotherapy, with comparable performance to stricter techniques like gating and DIBH while conferring greater time-saving benefits.
引用
收藏
页数:15
相关论文
共 50 条
[1]   Effect of MLC tracking latency on conformal volumetric modulated arc therapy (VMAT) plans in 4D stereotactic lung treatment [J].
Bedford, James L. ;
Fast, Martin F. ;
Nil, Simeon ;
McDonald, Fiona M. A. ;
Ahmed, Merina ;
Hansen, Vibeke N. ;
Oelfke, Uwe .
RADIOTHERAPY AND ONCOLOGY, 2015, 117 (03) :491-495
[2]   Dynamic conformal arcs for lung stereotactic body radiation therapy: A comparison with volumetric-modulated arc therapy [J].
Bokrantz, Rasmus ;
Wedenberg, Minna ;
Sandwall, Peter .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01) :103-109
[3]   MLC tracking for lung SABR is feasible, efficient and delivers high-precision target dose and lower normal tissue dose [J].
Booth, Jeremy ;
Caillet, Vincent ;
Briggs, Adam ;
Hardcastle, Nicholas ;
Angelis, Georgios ;
Jayamanne, Dasantha ;
Shepherd, Meegan ;
Podreka, Alexander ;
Szymura, Kathryn ;
Doan Trang Nguyen ;
Poulsen, Per ;
O'Brien, Ricky ;
Harris, Benjamin ;
Haddad, Carol ;
Eade, Thomas ;
Keall, Paul .
RADIOTHERAPY AND ONCOLOGY, 2021, 155 :131-137
[4]   Implementation and experimental results of 4D tumor tracking using robotic couch [J].
Buzurovic, I. ;
Yu, Y. ;
Werner-Wasik, M. ;
Biswas, T. ;
Anne, P. R. ;
Dicker, A. P. ;
Podder, T. K. .
MEDICAL PHYSICS, 2012, 39 (11) :6957-6967
[5]   A 3D-conformal technique is better than IMRT or VMAT for lung SBRT [J].
Cai, Jing ;
Malhotra, Harish K. ;
Orton, Colin G. .
MEDICAL PHYSICS, 2014, 41 (04)
[6]   DMLC tracking and gating can improve dose coverage for prostate VMAT [J].
Colvill, E. ;
Poulsen, P. R. ;
Booth, J. T. ;
O'Brien, R. T. ;
Ng, J. A. ;
Keall, P. J. .
MEDICAL PHYSICS, 2014, 41 (09)
[7]   An experimental evaluation of the Agility MLC for motion-compensated VMAT delivery [J].
Davies, G. A. ;
Clowes, P. ;
Bedford, J. L. ;
Evans, P. M. ;
Webb, S. ;
Poludniowski, G. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (13) :4643-4657
[8]   Organs at risk in lung SBRT [J].
De Rose, F. ;
Franceschini, D. ;
Reggiori, G. ;
Stravato, A. ;
Navarria, P. ;
Ascolese, A. M. ;
Tomatis, S. ;
Mancosu, P. ;
Scorsetti, M. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 :131-138
[9]   Technical Note: Comparison of the internal target volume (ITV) contours and dose calculations on 4DCT, average CBCT, and 4DCBCT imaging for lung stereotactic body radiation therapy (SBRT) [J].
Dumas, Michael ;
Laugeman, Eric ;
Sevak, Parag ;
Snyder, Karen C. ;
Mao, Weihua ;
Chetty, Indrin J. ;
Ajlouni, Munther ;
Wen, Ning .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (11) :288-294
[10]   Motion induced interplay effects for VMAT radiotherapy [J].
Edvardsson, Anneli ;
Nordstrom, Fredrik ;
Ceberg, Crister ;
Ceberg, Sofie .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (08)