BANANA STORAGE PERFORMANCE IN A REFRIGERATION SYSTEM WITH R404A REFRIGERANT AT DIFFERENT PRESSURES

被引:0
|
作者
Aksut, B. [1 ]
Polatci, H. [2 ]
机构
[1] Univ Tokat Gaziosmanpasa, Fac Agr, Dept Biosyst Engn, TR-60250 Tokat, Turkiye
[2] Univ Tokat Gaziosmanpasa, Fac Agr, Dept Horticulture, TR-60250 Tokat, Turkiye
关键词
Food quality; Gas performance; Image processing; Preservation; Quality; COLOR;
D O I
10.52292/j.laar.2023.1034
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this study, the storage performance of banana fruits in a refrigeration system at different pressures (950, 1050 and 1150 kPa) with R404A gas refrigerant was investigated. The trials lasted about 10 days. Weight loss (%), color changes, energy consumption and temperature values were determined. Total soluble solids (SSC), pH and total acidity (TA) of the fruits were also analyzed. The weight loss at the experiments was measured as %1.32 at 950 kPa pressure, %1.08 at 1050 kPa pressure and %1.30 at 1150 kPa pressure. Change in fruit surface areas throughout the storage period was determined with the aid of an image processing software. As compared to fresh fruits, SSC, pH and TA of the fruits were best-preserved at 950 kPa pressure. Therefore, 950 kPa pressure was recommended for R404A refrigerant in cold storage of banana fruits.
引用
收藏
页码:173 / 178
页数:6
相关论文
共 50 条
  • [21] Simulation study on refrigeration performance under frost condition in a R404A refrigerator truck type
    Kim, S. H.
    Kim, T. J.
    Shin, Y. C.
    Cho, H. H.
    INTERNATIONAL JOURNAL OF AUTOMOTIVE TECHNOLOGY, 2015, 16 (03) : 387 - 397
  • [22] Simulation study on refrigeration performance under frost condition in a R404A refrigerator truck type
    S. H. Kim
    T. J. Kim
    Y. C. Shin
    H. H. Cho
    International Journal of Automotive Technology, 2015, 16 : 387 - 397
  • [23] Failure analysis of condensing units for refrigerators with refrigerant R134a, R404A
    Bogdanovska, Gabriela
    Molnar, Vieroslav
    Fedorko, Gabriel
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 100 : 208 - 219
  • [24] The Effect the Effectiveness of the Liquid Suction Heat Exchanger to Performance of Cold Storage with Refrigerant R22, R404A and R290/R600a
    Prayudi
    Nurhasanah, Roswati
    Diantari, Retno Aita
    INTERNATIONAL CONFERENCE ON ENGINEERING, SCIENCE AND NANOTECHNOLOGY 2016 (ICESNANO 2016), 2017, 1788
  • [25] ENERGY AND EXERGY ANALYSIS OF A REFRIGERATION SYSTEM WITH SHELL AND TUBE HEAT EXCHANGER USING R404A
    Kabul, Ahmet
    Kizilkan, Onder
    Yakut, Ali Kemal
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2010, 30 (02) : 85 - 93
  • [26] Improvement of energy parameters using R442A and R453A in a refrigeration system operating with R404A
    Oruc, Vedat
    Devecioglu, Atilla G.
    Ender, Sertac
    APPLIED THERMAL ENGINEERING, 2018, 129 : 243 - 249
  • [27] FIELD MEASUREMENTS OF A R404A LOW-TEMPERATURE SUPERMARKET REFRIGERATION SYSTEM RETROFITTED WITH R449A
    Makhnatch, Pavel
    Mota-Babiloni, Adrian
    Khodabandeh, Rahmatollah
    Haro-Ortuno, Jorge
    5TH IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2018, : 468 - 474
  • [28] Comparison of a R744 cascade refrigeration system with R404A and R22 conventional systems for supermarkets
    da Silva, Alessandro
    Bandarra Filho, Enio Pedone
    Pontes Antunes, Arthur Heleno
    APPLIED THERMAL ENGINEERING, 2012, 41 : 30 - 35
  • [29] Retrofit of lower GWP alternative R449A into an existing R404A indirect supermarket refrigeration system
    Makhnatch, Pavel
    Mota-Babiloni, Adrian
    Rogstam, Jorgen
    Khodabandeh, Rahmatollah
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2017, 76 : 184 - 192
  • [30] Phenomena that accompany the condensation of R404A refrigerant in multiports during hydrodynamic instabilities
    Kuczynski, Waldemar
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (25-26) : 7718 - 7727