摘要
In this study, the storage performance of banana fruits in a refrigeration system at different pressures (950, 1050 and 1150 kPa) with R404A gas refrigerant was investigated. The trials lasted about 10 days. Weight loss (%), color changes, energy consumption and temperature values were determined. Total soluble solids (SSC), pH and total acidity (TA) of the fruits were also analyzed. The weight loss at the experiments was measured as %1.32 at 950 kPa pressure, %1.08 at 1050 kPa pressure and %1.30 at 1150 kPa pressure. Change in fruit surface areas throughout the storage period was determined with the aid of an image processing software. As compared to fresh fruits, SSC, pH and TA of the fruits were best-preserved at 950 kPa pressure. Therefore, 950 kPa pressure was recommended for R404A refrigerant in cold storage of banana fruits.
引用
收藏
页码:173 / 178
页数:6
相关论文
共 50 条
  • [1] Comparative analysis of thermodynamic performance of a cascade refrigeration system for refrigerant couples R41/R404A and R23/R404A
    Sun, Zhili
    Liang, Youcai
    Liu, Shengchun
    Ji, Weichuan
    Zang, Runqing
    Liang, Rongzhen
    Guo, Zhikai
    APPLIED ENERGY, 2016, 184 : 19 - 25
  • [2] EXPERIMENTAL STUDY ON REFRIGERATION SYSTEM 'S PERFORMANCE OF THE REFRIGERATOR TRUCK USING R404A REFRIGERANT
    Su, Zhiyong
    Zhao, Kunzheng
    Li, Haijun
    Zhang, Yibo
    THERMAL SCIENCE, 2024, 28 (3A): : 2033 - 2041
  • [3] Experimental study of a gas-injection refrigeration system using refrigerant mixtures to replace R404A
    Yoon, Il-Joo
    Kim, Jinyoung
    Lee, Dongchan
    Chung, Hyun Joon
    Kim, Yongchan
    APPLIED THERMAL ENGINEERING, 2023, 218
  • [4] Exergy characteristics of R404A indirect refrigeration system using CO2 as a secondary refrigerant
    Wen-Bin Yi
    Kwang-Hwan Choi
    Jung-In Yoon
    Chang-Hyo Son
    Soo-Jung Ha
    Min-Ju Jeon
    Heat and Mass Transfer, 2019, 55 : 1133 - 1142
  • [5] Exergetic performance assessment of a variable-speed R404a refrigeration system
    Kizilkan, Oender
    Kabul, Ahmet
    Yakut, Ali Kemal
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2010, 34 (06) : 463 - 475
  • [6] Exergy characteristics of R404A indirect refrigeration system using CO2 as a secondary refrigerant
    Yi, Wen-Bin
    Choi, Kwang-Hwan
    Yoon, Jung-In
    Son, Chang-Hyo
    Ha, Soo-Jung
    Jeon, Min-Ju
    HEAT AND MASS TRANSFER, 2019, 55 (04) : 1133 - 1142
  • [7] AN EXPERIMENTAL INVESTIGATION OF REFRIGERANT R449A AS REPLACEMENT FOR R404A IN SUPERMARKET REFRIGERATION SYSTEMS
    Makhnatch, P.
    Khodabandeh, R.
    4TH IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2016, : 324 - 331
  • [8] Thermal conductivity of liquid refrigerant R404A
    Baginsky A.V.
    Shipitsina A.S.
    Thermophysics and Aeromechanics, 2007, 14 (01) : 63 - 66
  • [9] Exergetic performance analysis of low GWP alternative refrigerants for R404A in a refrigeration system
    Altinkaynak, Mehmet
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2021, 16 (03) : 842 - 850
  • [10] THE EVALUATION OF LOW GWP NON-FLAMMABLE REFRIGERANT R407H FOR REFRIGERATION AS R404A ALTERNATIVE
    Ohkubo, Shun
    Arimoto, Hitomi
    Komatsu, Yuzo
    5TH IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2018, : 483 - 486