The dosimetric impact of titanium implants in spinal SBRT using four commercial treatment planning algorithms

被引:2
作者
Liu, Chieh-Wen [1 ]
Cho, Young-Bin [1 ]
Magnelli, Anthony [1 ]
Angelov, Lilyana [1 ]
Balagamwala, Ehsan H. [1 ]
Chao, Samuel T. [1 ]
Xia, Ping [1 ]
机构
[1] Cleveland Clin, Taussig Canc Inst, Dept Radiat Oncol, Cleveland, OH USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2023年 / 24卷 / 10期
关键词
algorithms; spinal implants; spine SBRT; treatment planning; MONTE-CARLO-SIMULATION; STEREOTACTIC RADIOSURGERY; RADIATION-THERAPY; DOSE DISTRIBUTION; ACUROS XB;
D O I
10.1002/acm2.14070
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the dosimetric impact of titanium implants in spine SBRT using four dose calculation algorithms. Twenty patients with titanium implants in the spine treated with SBRT without density override (DO) were selected. The clinical plan for each patient was created in Pinnacle and subsequently imported into Eclipse (AAA and AcurosXB) and Raystation (CC) for dose evaluation with and without DO to the titanium implant. We renormalized all plans such that 90% of the tumor volume received the prescription dose and subsequently evaluated the following dose metrics: (1) the maximum dose to 0.03 cc (Dmax), dose to 99% (D99%) and 90% (D90%) of the tumor volume; (2) Dmax and volumetric metrics of the spinal cord. For the same algorithm, plans with and without DO had similar dose distributions. Differences in Dmax, D99% and D90% of the tumor were on average <2% with slightly larger variations up to 5.58% in Dmax using AcurosXB. Dmax of the spinal cord for plans calculated with DO increased but the differences were clinically insignificant for all algorithms (mean: 0.36% & PLUSMN; 0.7%). Comparing to the clinical plans, the relative differences for all algorithms had an average of 1.73% (-10.36%-13.21%) for the tumor metrics and -0.93% (-9.87%-10.95%) for Dmax of the spinal cord. A few cases with small tumor and spinal cord volumes, dose differences of >10% in both D99% and Dmax of the tumor, and Dmax of the spinal cord were observed. For all algorithms, the presence of titanium implants in the spine for most patients had minimal impact on dose distributions with and without DO. For the same plan calculated with different algorithms, larger differences in volumetric metrics of >10% could be observed, impacted by dose gradient at the plan normalization volume, tumor volumes, plan complexity, and partial voxel volume interpolation.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Predicting vertebral compression fracture prior to spinal SBRT using radiomics from planning CT
    Seol, Yunji
    Song, Jin Ho
    Choi, Kyu Hye
    Lee, Young Kyu
    Choi, Byung-Ock
    Kang, Young-nam
    EUROPEAN SPINE JOURNAL, 2024, 33 (08) : 3221 - 3229
  • [22] Quantitative and qualitative performance evaluation of commercial metal artifact reduction methods: Dosimetric effects on the treatment planning
    Ghorbanzadeh, Mohammad
    Hosseini, Seyed Abolfazl
    Vahdat, Bijan Vosoughi
    Mirzaiy, Hamed
    Akhavanallaf, Azadeh
    Arabi, Hossein
    RADIATION PHYSICS AND CHEMISTRY, 2024, 225
  • [23] Dosimetric comparison of TMR10 and convolution dose calculation algorithms in GammaPlan treatment planning system
    Kendall, Ethan
    Algan, Ozer
    Chen, Yong
    Ahmad, Salahuddin
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (01) : 93 - 97
  • [24] Effects of metal implants and validation of four treatment planning methods used for radiotherapy dose calculation
    Gnanasambandam, Amirtharaj
    Raj, N. Arunai Nambi
    Sollinselvan, K.
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (05) : 821 - 831
  • [25] Dosimetric verification of a commercial Monte Carlo treatment planning system (VMC++) for a 9 MeV electron beam
    Schiapparelli, P.
    Zefiro, D.
    Taccini, G.
    MEDICAL PHYSICS, 2009, 36 (05) : 1759 - 1767
  • [26] Evaluation of Radiation Treatment Planning Algorithms in IMRT and VMAT: A Comparative Dosimetric Study in Lung Equivalent Heterogeneous Medium
    Mishra A.
    Pathak R.
    Raj Verma T.
    Srivastava A.K.
    Mishra S.P.
    Mittal K.K.
    Singh S.K.
    Journal of Biomedical Physics and Engineering, 2023, 13 (06) : 503 - 514
  • [27] Dosimetric impact of number of treatment fields in uniform scanning proton therapy planning of lung cancer
    Rana, Suresh
    Simpson, Hilarie
    Larson, Gary
    Zheng, Yuanshui
    JOURNAL OF MEDICAL PHYSICS, 2014, 39 (04) : 212 - 218
  • [28] Comparison of Proton Versus Photon SBRT for Treatment of Spinal Metastases Using Variable RBE Models
    Shaaban, Sherif G.
    Lecompte, Michael
    Chen, Hao
    Lubelski, Daniel
    Bydon, Ali
    Theodore, Nicholas
    Khan, Majid
    Lee, Sang
    Kebaish, Khaled
    Kleinberg, Lawrence
    Hooker, Ted
    Li, Heng
    Redmond, Kristin J.
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2025, 16
  • [29] Performance of Multiple Conformity, Homogeneity and Dose Gradient Indices in SRS and SBRT Treatment Planning of the Spinal, Pelvic and Lung Lesions
    Bassalow, R.
    Sabbas, A.
    Chang, J.
    Parashar, B.
    Wernicke, G.
    Chao, K.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [30] CyberKnife MLC-based treatment planning for abdominal and pelvic SBRT: Analysis of multiple dosimetric parameters, overall scoring index and clinical scoring
    Masi, Laura
    Zani, Margherita
    Doro, Raffaela
    Calusi, Silvia
    Di Cataldo, Vanessa
    Bonucci, Ivano
    Cipressi, Samantha
    Francolini, Giulio
    Bonomo, Pierluigi
    Livi, Lorenzo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 56 : 25 - 33