Monovision Correction Preference and Eye Dominance Measurements

被引:5
作者
Rodriguez-Lopez, Victor [1 ]
Barcala, Xoana [1 ,2 ]
Zaytouny, Amal [1 ]
Dorronsoro, Carlos [1 ,2 ]
Peli, Eli [3 ]
Marcos, Susana [1 ,4 ]
机构
[1] Spanish Natl Res Council IO CSIC, Inst Opt, Serrano 121, Madrid, Spain
[2] 2EyesVision SL, Madrid, Spain
[3] Harvard Med Sch, Inst Massachusetts Eye & Ear, Schepens Eye Res, Boston, MA USA
[4] Univ Rochester, Inst Opt, Flaum Eye Inst, Ctr Visual Sci, New York, NY USA
基金
欧洲研究理事会;
关键词
monovision; eye dominance; presbyopia; prescription; visual simulator; perceived quality; INTEROCULAR SUPPRESSION; OCULAR DOMINANCE; BLUR;
D O I
10.1167/tvst.12.3.18
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To propose new methods for eye selection in presbyopic monovision corrections.Methods: Twenty subjects with presbyopia performed two standard methods of binary eye dominance identification (sensory with +1.50 diopters [D ]and +0.50 D and sighting with "hole-in-the-card") and two psychophysical methods of perceived visual quality: (1) the Preferential test, 26 natural images were judged with the near addition in one eye or in the other in a 2-interval forced-choice task, and the Eye Dominance Strength (EDS) defined as the proportion of trials where one monovision is preferred over the other; (2) the Multifocal Acceptance Score (MAS-2EV) test, the perceived quality of a natural images set (for 2 luminance levels and distances) was scored and EDS defined as the score difference between monovision in one eye or the other. Left-eye and right -eye dominance are indicated with negative and positive values, respectively. Tests were performed using a Simultaneous Vision Simulator, which allows rapid changes between corrections.Results: Standard sensory and sighting dominances matched in only 55% of subjects. The Preferential EDS (ranging from -0.7 to +0.9) and MAS-2EV EDS (ranging from -0.6 to +0.4) were highly correlated. Selecting the eye for far in monovision with the MAS-2EV, sensory, or sighting tests would have resulted in 79%, 64%, and 43% success consid-ering the Preferential test as the gold standard.Conclusions: Tests based on perceptual preference allow selection of the preferred monovision correction and measurement of dominance strength.Translational Relevance: The binocular visual simulator allows efficient implementa-tion of eye preference tests for monovision in clinical use.
引用
收藏
页数:12
相关论文
共 30 条
[1]  
[Anonymous], 2002, Seeing in depth
[3]  
Barcala X., 2022, CONTACT LENS ANTERIO, V20
[4]   Multifocal acceptance score to evaluate vision: MAS-2EV [J].
Barcala, Xoana ;
Vinas, Maria ;
Romero, Mercedes ;
Gambra, Enrique ;
Luis Mendez-Gonzalez, Juan ;
Marcos, Susana ;
Dorronsoro, Carlos .
SCIENTIFIC REPORTS, 2021, 11 (01)
[5]   The psychophysics toolbox [J].
Brainard, DH .
SPATIAL VISION, 1997, 10 (04) :433-436
[6]  
COLLINS MJ, 1994, ACTA OPHTHALMOL, V72, P376
[7]  
COREN S, 1973, AM J OPTOM PHYS OPT, V50, P283
[8]   Individual differences in sensory eye dominance reflected in the dynamics of binocular rivalry [J].
Dieter, Kevin. C. ;
Sy, Jocelyn L. ;
Blake, Randolph .
VISION RESEARCH, 2017, 141 :40-50
[9]   Tunable lenses: dynamic characterization and fine-tuned control for high-speed applications [J].
Dorronsoro, Carlos ;
Barcala, Xoana ;
Gambra, Enrique ;
Akondi, Vyas ;
Sawides, Lucie ;
Marrakchi, Yassine ;
Rodriguez-Lopez, Victor ;
Benedi-Garcia, Clara ;
Vinas, Maria ;
Lage, Eduardo ;
Marcos, Susana .
OPTICS EXPRESS, 2019, 27 (03) :2085-2100
[10]   Portable simultaneous vision device to simulate multifocal corrections [J].
Dorronsoro, Carlos ;
Radhakrishnan, Aiswaryah ;
Ramon Alonso-Sanz, Jose ;
Pascual, Daniel ;
Velasco-Ocana, Miriam ;
Perez-Merino, Pablo ;
Marcos, Susana .
OPTICA, 2016, 3 (08) :918-924