Computational analysis of blind performance on natural ventilated double skin fasade in winter

被引:8
作者
Arabi, Pouria [1 ]
Hamidpour, Mahmoud Reza [2 ]
Yaghoubi, Mahmood [1 ,3 ]
Arabi, Faraz [4 ]
机构
[1] Shiraz Univ, Sch Mech Engn, Shiraz 7193616548, Iran
[2] Isfahan Univ Technol, Sch Mech Engn, Esfahan 8415683111, Iran
[3] Acad Sci IR Iran, POB 19735-167, Tehran, Iran
[4] Univ Tehran, Sch Mech Engn, Tehran 1439957131, Iran
关键词
Double skin fasade (DSF); Natural ventilation; Energy saving; Solar energy; Dynamic efficiency; Computational fluid dynamics (CFD); AIR-FLOW; THERMAL PERFORMANCE; ENERGY PERFORMANCE; HEAT-TRANSFER; FACADE; SIMULATION; BUILDINGS; BEHAVIOR; MODEL; VALIDATION;
D O I
10.1016/j.energy.2023.126719
中图分类号
O414.1 [热力学];
学科分类号
摘要
Double Skin Fasade (DSF) are broadly employed for state-of-the-art and high-rise buildings due to considerable advantages. DSF are used with or without solar shading devices such as venetian blinds. The complex flow of natural ventilation in DSF is affected by many parameters such as blind size, position and angle, and solar irradiance. The impact of blinds size and position upon the vast array of main parameters such as temperature, mass flow rate, flow dimensionless number, turbulent kinetic energy, dynamic efficiency, and absorbed solar radiation rate of walls is investigated through Computational Fluid Dynamic (CFD). The analysis is based upon validation with experimental measurements and grid-sensitivity analysis. Five different blind sizes (30 mm, 60 mm, 120 mm, 240 mm, and 320 mm) and three varied blind positions (near to the outer glazing, middle of the DSF channel, and near to the inner double-glazing) are considered as design parameter of blinds. The results indicate that by increasing the blind size from 30 mm to 320 mm when blinds positioned near to the outer glazing, average temperature of DSF walls and outlet air temperature of DSF climbs although average mass flow rate decreases. The interaction between average mass flow rate and temperature difference between inlet and outlet air temperature of DSF determines the extracted heat rate (dynamic efficiency) of DSF. When the blind size rises from 30 mm to 240 mm, dynamic efficiency soars markedly whereas it decreases from 240 mm to 320 mm. In addition, as the blind size becomes larger, the absorbed solar radiation rate of blinds shoots up though the absorbed solar radiation rate of inner double-glazing plunges sharply from 30 mm to 240 mm. On the other hand, by moving the blinds towards the outer glazing for specified blind size, the temperature of DSF outlet air and average mass flow rate grows and dynamic efficiency of DSF climbs. As blinds move toward the outer glazing, there is a gentle rise in the absorbed solar radiation rate of blinds whereas there is a moderate decline in that of inner double-glazing. Generally speaking, positioning the blinds close to the outer glazing and increasing their size improve the performance of DSF in winter.
引用
收藏
页数:22
相关论文
共 53 条
  • [1] Optimal design and placement of heat sink elements attached on a cylindrical heat-generating body for maximum cooling performance
    Ahmadian-Elmi, M.
    Mohammadifar, M.
    Rasouli, E.
    Hajmohammadi, M. R.
    [J]. THERMOCHIMICA ACTA, 2021, 700
  • [2] Ahmed Mostafa M. S., 2016, Journal of Clean Energy Technologies, V4, P84, DOI 10.7763/JOCET.2016.V4.258
  • [3] Experimental validation of a EnergyPlus model: Application of a multi-storey naturally ventilated double skin facade
    Andelkovic, Aleksandar S.
    Mujan, Igor
    Dakic, Stojanka
    [J]. ENERGY AND BUILDINGS, 2016, 118 : 27 - 36
  • [4] Experimental research of the thermal characteristics of a multi-storey naturally ventilated double skin facade
    Andelkovic, Aleksandar S.
    Gvozdenac-Urosevic, Branka
    Kljajic, Miroslav
    Ignjatovic, Marko G.
    [J]. ENERGY AND BUILDINGS, 2015, 86 : 766 - 781
  • [5] Perspectives of double skin facades for naturally ventilated buildings: A review
    Barbosa, Sabrina
    Ip, Kenneth
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 40 : 1019 - 1029
  • [6] Experimental and numerical study of energy loss through double-glazed windows
    Bitaab, Mohammadhassan
    Hosseini Abardeh, Reza
    Movahhed, Saeid
    [J]. HEAT AND MASS TRANSFER, 2020, 56 (03) : 727 - 747
  • [7] Cengel YunusA., 2020, HEAT MASS TRANSFER F
  • [8] Calculation of overall thermal transfer value (OTTV) for commercial buildings constructed with naturally ventilated double skin facade in subtropical Hong Kong
    Chan, A. L. S.
    Chow, T. T.
    [J]. ENERGY AND BUILDINGS, 2014, 69 : 14 - 21
  • [9] Investigation on energy performance of double skin facade in Hong Kong
    Chan, A. L. S.
    Chow, T. T.
    Fong, K. F.
    Lin, Z.
    [J]. ENERGY AND BUILDINGS, 2009, 41 (11) : 1135 - 1142
  • [10] Naturally ventilated double-skin facade in modeling and experiments
    Dama, Alessandro
    Angeli, Diego
    Larsen, Olena Kalyanova
    [J]. ENERGY AND BUILDINGS, 2017, 144 : 17 - 29