Ultra-sensitive relative humidity sensor formed by two parallel Fabry-Perot interferometers and Vernier effect

被引:5
|
作者
Shu, Yukun [1 ]
Jiang, Chao [1 ]
Deng, Longfeng [1 ]
Hu, Chuanju [1 ]
Gao, Jiawei [1 ]
Li, Li [1 ]
Li, Hong [1 ]
Sun, Simei [1 ]
机构
[1] Hubei Normal Univ, Coll Phys & Elect Sci, Hubei Key Lab Optoelect Convers Mat & Devices, Hubei Engn Res Ctr Micronano Optoelect Devices & I, Huangshi 435002, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
Optical fiber sensor; Fabry-Perot interferometer; Gelatin diaphragm; Relative humidity; Vernier effect;
D O I
10.1016/j.infrared.2024.105185
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, a relative humidity (RH) Vernier sensor based on gelatin diaphragm is proposed, in which the gelatin diaphragm is coated on the end surface of the quartz capillary by the dot-dip method, so that the prepared diaphragm is only 3 mu m thick. The sensing cavity FPI1 is an air-cavity made of single -mode -fiber (SMF), quartz capillary (QC) and gelatin diaphragm. Gelatin diaphragm is an excellent humidity sensitive material, therefore FPI1 has high sensitivity to humidity. The reference cavity FPI2 is also an air-cavity spliced in the order of SMFQC-SMF. When FPI1 and FPI2 have similar free spectral range, they form a Vernier effect in parallel, achieving maximum humidity sensitivity. The experimental results show that in the range of 1300 nm to 1650 nm, the envelope formed by two parallel FPIs is particularly regular and has a free spectral range of 95.2 nm. By tracking the variation of the envelope dip with humidity, the sensor obtained a highly fitting polynomial relationship in the range of 57 %RH - 84 %RH. However, in the range of 75 %RH - 84 %RH, the sensor achieved an excellent linear fitting relationship, with a linearity of up to 0.9997 and a sensitivity of up to 27.9726 nm/%RH. This is the most sensitive gelatin Vernier humidity sensor ever reported. And the crosstalk of temperature of the Vernier humidity sensor is only 0.0186 %RH/celcius. The sensor is easy to manufacture, ultra -high sensitivity, small temperature crosstalk, good performance and low cost, and has good reversibility and stability. It is a competitive humidity candidate sensor.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Relative humidity sensor based on cascaded Fabry-Perot interferometers and Vernier effect
    Wang, Yuan
    Zhu, Xiping
    Chen, Hailin
    Jiang, Chao
    Guo, Xiaoshan
    Sun, Simei
    OPTIK, 2022, 254
  • [2] High sensitivity relative humidity sensor based on two parallel-connected Fabry-Perot interferometers and Vernier effect
    Wang, Yuan
    Jiang, Chao
    Guo, Xiaoshan
    Chen, Hailin
    Song, Jiao
    Sun, Simei
    OPTICAL FIBER TECHNOLOGY, 2022, 68
  • [3] Optical fiber humidity sensor based on vernier effect of Fabry-Perot interferometers with microsphere
    Liu, Yiting
    Gong, Huaping
    Lu, Xiao
    Ni, Kai
    Zhao, Chunliu
    Shen, Changyu
    OPTICAL FIBER TECHNOLOGY, 2023, 76
  • [4] Parallel Fiber Fabry-Perot Temperature and Humidity Sensor Based on Vernier Effect
    Ke, Xinyi
    Chang, Jianhua
    Min, Yang
    Wu, Xinxin
    Hu, Ziyi
    ACTA OPTICA SINICA, 2025, 45 (02)
  • [5] Ultrasensitive gas pressure sensor based on two parallel Fabry-Perot interferometers and enhanced Vernier effect
    Zhu, Xiping
    Jiang, Chao
    Chen, Hailin
    Wang, Yuan
    Guo, Xiaoshan
    Sun, Simei
    Huang, Huiling
    OPTICS AND LASER TECHNOLOGY, 2023, 158
  • [6] High-Sensitivity Temperature Sensor Based on Two Parallel Fabry-Perot Interferometers and Vernier Effect
    Zhang, Shiyi
    Jiang, Chao
    Ren, Jie
    Chen, Hailin
    Song, Jiao
    Guo, Xiaoshan
    Sun, Simei
    JOURNAL OF RUSSIAN LASER RESEARCH, 2022, 43 (03) : 319 - 327
  • [7] Hypersensitive high-temperature gas pressure sensor with Vernier effect by two parallel Fabry-Perot interferometers
    Han, Zhao
    Xin, Guoguo
    Nan, Pengyu
    Liu, Ji
    Zhu, Jiajie
    Yang, Hangzhou
    OPTIK, 2021, 241
  • [8] High sensitivity gas pressure sensor based on two parallel-connected Fabry-Perot interferometers and Vernier effect
    Guo, Xiaoshan
    Ye, Wenhao
    Jiang, Chao
    Sun, Simei
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (12)
  • [9] Vernier Effect-Based Strain Sensor With Cascaded Fabry-Perot Interferometers
    Abbas, Lashari Ghulam
    IEEE SENSORS JOURNAL, 2020, 20 (16) : 9196 - 9201
  • [10] High-Sensitive Temperature Sensor With Cascaded Fabry-Perot Interferometers Based on Enhanced Vernier Effect
    Liu, Yubo
    Zhang, Wei
    Chen, Ying
    Chen, Duo
    Qi, Yuxuan
    Lv, Jiacheng
    Li, Wenjing
    Yu, Zhuqing
    Yu, Zhuoran
    Ni, Jiasheng
    Zhao, Yanjie
    IEEE SENSORS JOURNAL, 2025, 25 (01) : 561 - 568