Design and Performance Evaluation of a Novel Spiral Head-Stem Trunnion for Hip Implants Using Finite Element Analysis

被引:4
作者
Soliman, Md Mohiuddin [1 ]
Chowdhury, Muhammad E. H. [2 ]
Islam, Mohammad Tariqul [3 ]
Musharavati, Farayi [4 ]
Mahmud, Sakib [2 ]
Hafizh, Muhammad [4 ]
Ayari, Mohamed Arselene [5 ]
Khandakar, Amith [2 ]
Alam, Mohammad Kaosar [2 ]
Nezhad, Erfan Zal [6 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Elect Elect & Syst Engn, Bangi 43600, Selangor, Malaysia
[2] Qatar Univ, Dept Elect Engn, Doha, Qatar
[3] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Ctr Adv Elect & Commun Engn, Dept Elect Elect & Syst Engn, Bangi 43600, Selangor, Malaysia
[4] Qatar Univ, Dept Mech & Ind Engn, Doha, Qatar
[5] Qatar Univ, Dept Civil & Architectural Engn, Doha, Qatar
[6] Univ Texas San Antonio, Dept Biomed Engn, San Antonio, TX 78249 USA
关键词
spiral head-stem trunnion; contact pressure; sliding distance; wear rate; TAPER JUNCTION; FRETTING WEAR; CONTACT PRESSURE; FEMORAL HEADS; METAL; CORROSION; PREDICTION; SIZE; REPLACEMENTS; PROSTHESIS;
D O I
10.3390/ma16041466
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
With an expectation of an increased number of revision surgeries and patients receiving orthopedic implants in the coming years, the focus of joint replacement research needs to be on improving the mechanical properties of implants. Head-stem trunnion fixation provides superior load support and implant stability. Fretting wear is formed at the trunnion because of the dynamic load activities of patients, and this eventually causes the total hip implant system to fail. To optimize the design, multiple experiments with various trunnion geometries have been performed by researchers to examine the wear rate and associated mechanical performance characteristics of the existing head-stem trunnion. The objective of this work is to quantify and evaluate the performance parameters of smooth and novel spiral head-stem trunnion types under dynamic loading situations. This study proposes a finite element method for estimating head-stem trunnion performance characteristics, namely contact pressure and sliding distance, for both trunnion types under walking and jogging dynamic loading conditions. The wear rate for both trunnion types was computed using the Archard wear model for a standard number of gait cycles. The experimental results indicated that the spiral trunnion with a uniform contact pressure distribution achieved more fixation than the smooth trunnion. However, the average contact pressure distribution was nearly the same for both trunnion types. The maximum and average sliding distances were both shorter for the spiral trunnion; hence, the summed sliding distance was approximately 10% shorter for spiral trunnions than that of the smooth trunnion over a complete gait cycle. Owing to a lower sliding ability, hip implants with spiral trunnions achieved more stability than those with smooth trunnions. The anticipated wear rate for spiral trunnions was 0.039 mm(3), which was approximately 10% lower than the smooth trunnion wear rate of 0.048 mm(3) per million loading cycles. The spiral trunnion achieved superior fixation stability with a shorter sliding distance and a lower wear rate than the smooth trunnion; therefore, the spiral trunnion can be recommended for future hip implant systems.
引用
收藏
页数:19
相关论文
共 17 条
  • [1] Wear estimation of hip implants with varying chamfer geometry at the trunnion junction: a finite element analysis
    Gutmann, Celine
    Shaikh, Numa
    Shenoy, B. Satish
    Bhat, N. Shaymasunder
    Keni, Laxmikant G.
    Chethan, K. N.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (03)
  • [2] The onset of fretting at the head-stem connection in hip arthroplasty is affected by head material and trunnion design under simulated corrosion conditions
    Rowan, Fiachra E.
    Wach, Amanda
    Wright, Timothy M.
    Padgett, Douglas E.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (06) : 1630 - 1636
  • [3] A combined experimental and finite element approach to analyse the fretting mechanism of the head-stem taper junction in total hip replacement
    Bitter, Thom
    Khan, Imran
    Marriott, Tim
    Lovelady, Elaine
    Verdonschot, Nico
    Janssen, Dennis
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (09) : 862 - 870
  • [4] Wear estimation of trapezoidal and circular shaped hip implants along with varying taper trunnion radiuses using finite element method
    Chethan, K. N.
    Ogulcan, Guldeniz
    Bhat, Shyamasunder N.
    Zuber, Mohammad
    Shenoy, Satish B.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 196
  • [5] Static, Transient, and Fatigue Design and Analysis of a Hip Femoral Stem Using the Finite Element Method
    Anticona-Valderrama, Daniela Milagros
    Serna-Landivar, Jose L.
    Algoner, William C.
    Miranda, Manuel Lopez
    Garcia-Alvarez, Maria Ysabel
    Landivar, Leslie Katerine Serna
    INTERNATIONAL JOURNAL OF ONLINE AND BIOMEDICAL ENGINEERING, 2024, 20 (16) : 89 - 102
  • [6] Does a micro-grooved trunnion stem surface finish improve fixation and reduce fretting wear at the taper junction of total hip replacements? A finite element evaluation
    Ashkanfar, Ariyan
    Langton, David J.
    Joyce, Thomas J.
    JOURNAL OF BIOMECHANICS, 2017, 63 : 47 - 54
  • [7] Prediction of bone ingrowth into a porous novel hip-stem: A finite element analysis integrated with mechanoregulatory algorithm
    Loha, Tanmoy
    Mukherjee, Kaushik
    Pal, Bidyut
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2024, 238 (10) : 992 - 1004
  • [8] Elastohydrodynamic lubrication analysis of metal-on-metal hip implants with complex structures using the finite-element method
    Meng, Q. E.
    Liu, F.
    Jin, Z. M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2010, 224 (J9) : 1007 - 1018
  • [9] Proximal cementation of a collarless polished tapered hip stem: biomechanical analysis using a validated finite element model
    Ling, Carol Sze Yee
    Izmin, Aiman
    Todo, Mitsugu
    Merican, Azhar M.
    Chong, Desmond Y. R.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (11) : 3531 - 3542
  • [10] Design process of cementless femoral stem using a nonlinear three dimensional finite element analysis
    Baharuddin, Mohd Yusof
    Salleh, Sh-Hussain
    Zulkifly, Ahmad Hafiz
    Lee, Muhammad Hisyam
    Noor, Alias Mohd
    Harris, Arief Ruhullah A.
    Majid, Norazman Abdul
    Abd Kader, Ab Saman
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15