A commercial graphene-amine (CGA) and synthesized selenium nanoparticle (SSeNP) nanocomposite coated on the surface of fluorine-doped tin oxide (SSeNPs-CGA-FTO) substrate was developed by spin coating for H2O2 detection. The CGA-FTO and SSeNPs-CGA-FTO electrochemical sensors were characterized using FESEM with EDAX analysis. FESEM analysis showed nanotube and fluffy morphology of the SSeNPs and CGA, respectively. The developed CGA-FTO and SSeNPs-CGA-FTO electrochemical sensors were used for the sensing of hydrogen peroxide by chronoamperometry (CA) in NaOH (0.1 N) electrolyte. The sensors showed a linear response range from 0.1 mM to 20 mM with sensitivity of 101.7 mA mM(-1) cm(-2) (R-2 = 0.9931) and 137.9 mA mM(-1) cm(-2) (R-2 = 0.9956). The CGA-FTO and SSeNPs-CGA-FTO showed a very low detection limit of 0.1 mM and 0.05 mM, respectively, with a detection response time of less than 1 s. The interference study of the SSeNPs-CGA-FTO-based sensors showed higher selectivity towards H2O2 with interfering agents as compared with CGA-FTO.
引用
收藏
页码:6800 / 6814
页数:15
相关论文
共 50 条
  • [41] A Multicomponent Polymer-Metal-Enzyme System as Electrochemical Biosensor for H2O2 Detection
    Tong, Pengfei
    Asif, Muhammad
    Ajmal, Muhammad
    Aziz, Ayesha
    Sun, Yimin
    FRONTIERS IN CHEMISTRY, 2022, 10
  • [42] Fabrication of hollow CuO/PANI hybrid nanofibers for non-enzymatic electrochemical detection of H2O2 and glucose
    Liu, Tianjiao
    Guo, Yuqi
    Zhang, Zhenfang
    Miao, Zhicong
    Zhang, Xiaoyuan
    Su, Zhiqiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 286 : 370 - 376
  • [43] Preparation of HRP Molecularly Imprinted Electrochemical Sensor with Multi-walled Carbon Nanotubes as Sensitizing Materials and the Detection of H2O2
    Teng, Yu
    Yang, Shaoming
    Bai, Chaopeng
    Zhang, Jian
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2020, 41 (01): : 78 - 86
  • [44] Nanostructured Metal Organic Framework Modified Glassy Carbon Electrode as a High Efficient Non-Enzymatic Amperometric Sensor for Electrochemical Detection of H2O2
    Naseri, Maryam
    Fotouhi, Lida
    Ehsani, Ali
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2018, 9 (01) : 28 - 36
  • [45] An Electrochemical H2O2 Detection Method Based on Direct Electrochemistry of Myoglobin Immobilized on Gold Deposited ITO Electrode
    Dengale, Santosh Machhindra
    Yagati, Ajay Kumar
    Chung, Yong-Ho
    Min, Junhong
    Choi, Jeong-Woo
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2013, 13 (09) : 6424 - 6428
  • [46] Enzymatic assay of histamine by amperometric detection of H2O2 with a peroxidase-based sensor
    Hibi, T
    Senda, M
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2000, 64 (09) : 1963 - 1966
  • [47] Electrochemical sensor for H2O2 using a glassy carbon electrode modified with a nanocomposite consisting of graphene oxide, cobalt(III) oxide, horseradish peroxidase and nafion
    Safi Asim Bin Asif
    Sher Bahadar Khan
    Abdullah M. Asiri
    Microchimica Acta, 2016, 183 : 3043 - 3052
  • [48] Investigation of Photo-induced enhancement of sensitivity and electrochemical surface phenomenon of multileg TiO2 nanotubes sensor device towards H2O2
    Lekha, P. Chithra
    Babu, Y. Ram
    Kumar, V. T. Fidal
    Chandra, T. S.
    Roy, Somnath C.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 895 (895)
  • [49] Electrochemical sensor for H2O2 using a glassy carbon electrode modified with a nanocomposite consisting of graphene oxide, cobalt(III) oxide, horseradish peroxidase and nafion
    Bin Asif, Safi Asim
    Khan, Sher Bahadar
    Asiri, Abdullah M.
    MICROCHIMICA ACTA, 2016, 183 (11) : 3043 - 3052
  • [50] Preparation of SnS2/MWCNTs chemically modified electrode and its electrochemical detection of H2O2
    Duan, Zhihong
    Huang, Chaolian
    Yang, Xiaoxiao
    Hu, Ailin
    Lu, Xiaoying
    Jiang, Qi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (18) : 4403 - 4412