Electroanalytical Study of SSeNPs-CGA-FTO Electrochemical Sensor Towards the Detection of H2O2

被引:2
|
作者
Dumore, Nilesh S. [1 ,2 ]
Mukhopadhyay, Mausumi [2 ]
机构
[1] Sitarambhai Naranji Patel Inst Technol, Res Ctr, Dept Chem Engn, Umrakh 394601, Gujarat, India
[2] Sardar Vallabhbhai Natl Inst Technol, Dept Chem Engn, Surat 395007, Gujarat, India
关键词
Selenium nanoparticles; graphene amine; FTO; electrochemical sensor; cyclic voltammetry; amperometry; FUNCTIONALIZED CARBON NANOTUBES; SELENIUM NANOPARTICLES; BIMETALLIC NANOPARTICLES; ELECTRON-TRANSFER; GLUCOSE-OXIDASE; GRAPHENE OXIDE; BIOSENSOR; COMPOSITE;
D O I
10.1007/s11664-023-10612-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A commercial graphene-amine (CGA) and synthesized selenium nanoparticle (SSeNP) nanocomposite coated on the surface of fluorine-doped tin oxide (SSeNPs-CGA-FTO) substrate was developed by spin coating for H2O2 detection. The CGA-FTO and SSeNPs-CGA-FTO electrochemical sensors were characterized using FESEM with EDAX analysis. FESEM analysis showed nanotube and fluffy morphology of the SSeNPs and CGA, respectively. The developed CGA-FTO and SSeNPs-CGA-FTO electrochemical sensors were used for the sensing of hydrogen peroxide by chronoamperometry (CA) in NaOH (0.1 N) electrolyte. The sensors showed a linear response range from 0.1 mM to 20 mM with sensitivity of 101.7 mA mM(-1) cm(-2) (R-2 = 0.9931) and 137.9 mA mM(-1) cm(-2) (R-2 = 0.9956). The CGA-FTO and SSeNPs-CGA-FTO showed a very low detection limit of 0.1 mM and 0.05 mM, respectively, with a detection response time of less than 1 s. The interference study of the SSeNPs-CGA-FTO-based sensors showed higher selectivity towards H2O2 with interfering agents as compared with CGA-FTO.
引用
收藏
页码:6800 / 6814
页数:15
相关论文
共 50 条
  • [11] Nanoporous PtNi alloy as an electrochemical sensor for ethanol and H2O2
    Xu, Caixia
    Wang, Jinping
    Zhou, Jianhua
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 182 : 408 - 415
  • [12] Non-Enzymatic CO3O4 Nanostructure-Based Electrochemical Sensor for H2O2 Detection
    Mizers, V.
    Gerbreders, V.
    Krasovska, M.
    Sledevskis, E.
    Mihailova, I.
    Ogurcovs, A.
    Bulanovs, A.
    Gerbreders, A.
    LATVIAN JOURNAL OF PHYSICS AND TECHNICAL SCIENCES, 2023, 60 (06) : 63 - 84
  • [13] Ultrasensitive detection of H2O2 via electrochemical sensor by graphene synergized with MOF-on-MOF nanozymes
    Gao, Haifeng
    Yu, Haiting
    Yang, Shuang
    Chai, Fang
    Wu, Hongbo
    Tian, Miaomiao
    MICROCHIMICA ACTA, 2024, 191 (08)
  • [14] An electrochemical sensor based on multiferroic NdFeO3 particles modified electrode for the detection of H2O2
    Rajaitha, P. Mary
    Hajra, Sugato
    Padhan, Aneeta Manjari
    Panda, Swati
    Sahu, Manisha
    Kim, Hoe Joon
    JOURNAL OF ALLOYS AND COMPOUNDS, 2022, 915
  • [15] "Turn-on" ratiometric electrochemical detection of H2O2 in one drop of whole blood sample via a novel microelectrode sensor
    Dong, Hui
    Zhou, Yanli
    Hao, Yuanqiang
    Zhao, Le
    Sun, Shuo
    Zhang, Yintang
    Ye, Baoxian
    Xu, Maotian
    BIOSENSORS & BIOELECTRONICS, 2020, 165 (165)
  • [16] Electrochemical sensor based on rGO/Au nanoparticles for monitoring H2O2 released by human macrophages
    Patella, B.
    Buscetta, M.
    Di Vincenzo, S.
    Ferraro, M.
    Aiello, G.
    Sunseri, C.
    Pace, E.
    Inguanta, R.
    Cipollina, C.
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 327
  • [17] Electrochemical H2O2 Sensor Based on Graphene Oxide-Iron Oxide Nanoparticles Composite
    Bas, Salih Zeki
    Ozmen, Mustafa
    Yildiz, Salih
    PROCEEDINGS OF THE 2017 IEEE 7TH INTERNATIONAL CONFERENCE NANOMATERIALS: APPLICATION & PROPERTIES (NAP), 2017,
  • [18] Specifically triggered dissociation based ratiometric electrochemical sensor for H2O2 measurement in food samples
    Luo, Shan
    Kan, Xianwen
    FOOD CHEMISTRY, 2022, 387
  • [19] ELECTROCHEMICAL BEHAVIOR OF THE HEMIN MODIFIED GRAPHITE ELECTRODE FOR H2O2 DETECTION
    Mares, Georgeta Maria
    Turdean, Graziella Liana
    Popescu, Ionel Catalin
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2013, 58 (02): : 105 - 114
  • [20] A novel electrochemical sensor based on CuO-CeO2/MXene nanocomposite for quantitative and continuous detection of H2O2
    Zhou, Kaiwei
    Li, Yang
    Zhuang, Shujuan
    Ren, Jie
    Tang, Feng
    Mu, Jinglin
    Wang, Ping
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 921