Evaluating feasibility of functional near-infrared spectroscopy in dolphins

被引:3
作者
Ruesch, Alexander [1 ,2 ]
Acharya, Deepshikha [2 ]
Bulger, Eli [2 ]
Cao, Jiaming [2 ]
McKnight, J. Christopher [3 ]
Manley, Mercy [4 ]
Fahlman, Andreas [5 ,6 ,7 ]
Shinn-Cunningham, Barbara G. [1 ,2 ]
Kainerstorfer, Jana M. [1 ,2 ]
机构
[1] Carnegie Mellon Univ, Neurosci Inst, Pittsburgh, PA 15213 USA
[2] Carnegie Mellon Univ, Dept Biomed Engn, Pittsburgh, PA 15213 USA
[3] Univ St Andrews, Sea Mammal Res Unit, St Andrews, Scotland
[4] Siegfried & Roys Secret Garden & Dolphin Habitat, Mirage Hotel & Casino, Las Vegas, NV USA
[5] Fdn Oceanog Comunitat Valenciana, Valencia, Spain
[6] Global Diving Res SL, Valencia, Spain
[7] Kolmarden Wildlife Pk, Kolmarden, Sweden
关键词
marine mammals; functional near-infrared spectroscopy; tissue optical properties; dolphin; DIFFUSE OPTICAL TOMOGRAPHY; INSTRUMENTATION; METABOLISM; TISSUES; DESIGN;
D O I
10.1117/1.JBO.28.7.075001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance: Using functional near-infrared spectroscopy (fNIRS) in bottlenose dolphins (Tursiops truncatus) could help to understand how echolocating animals perceive their environment and how they focus on specific auditory objects, such as fish, in noisy marine settings. Aim: To test the feasibility of near-infrared spectroscopy (NIRS) in medium-sized marine mammals, such as dolphins, we modeled the light propagation with computational tools to determine the wavelengths, optode locations, and separation distances that maximize sensitivity to brain tissue. Approach: Using frequency-domain NIRS, we measured the absorption and reduced scattering coefficient of dolphin sculp. We assigned muscle, bone, and brain optical properties from the literature and modeled light propagation in a spatially accurate and biologically relevant model of a dolphin head, using finite-element modeling. We assessed tissue sensitivities for a range of wavelengths (600 to 1700 nm), source-detector distances (50 to 120 mm), and animal sizes (juvenile model 25% smaller than adult). Results: We found that the wavelengths most suitable for imaging the brain fell into two ranges: 700 to 900 nm and 1100 to 1150 nm. The optimal location for brain sensing positioned the center point between source and detector 30 to 50 mm caudal of the blowhole and at an angle 45 deg to 90 deg lateral off the midsagittal plane. Brain tissue sensitivity comparable to human measurements appears achievable only for smaller animals, such as juvenile bottlenose dolphins or smaller species of cetaceans, such as porpoises, or with source-detector separations >> 100 mm in adult dolphins. Conclusions: Brain measurements in juvenile or subadult dolphins, or smaller dolphin species, may be possible using specialized fNIRS devices that support optode separations of >100 mm. We speculate that many measurement repetitions will be required to overcome hemodynamic signals originating predominantly from the muscle layer above the skull. NIRS measurements of muscle tissue are feasible today with source-detector separations of 50 mm, or even less. (c) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License.
引用
收藏
页数:18
相关论文
共 50 条
[31]   On fractality of functional near-infrared spectroscopy signals: analysis and applications [J].
Zhu, Li ;
Haghani, Sasan ;
Najafizadeh, Laleh .
NEUROPHOTONICS, 2020, 7 (02)
[32]   Evaluation and diagnosis of brain death by Functional near-infrared spectroscopy [J].
Pan, Boan ;
Zhong, Fulin ;
Huang, Xiaobo ;
Pan, Lingai ;
Lu, Sen ;
Li, Ting .
ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XV, 2017, 10054
[33]   Interpolated functional manifold for functional near-infrared spectroscopy analysis at group level [J].
Avila-Sansores, Shender-Maria ;
Rodriguez-Gomez, Gustavo ;
Tachtsidis, Ilias ;
Orihuela-Espina, Felipe .
NEUROPHOTONICS, 2020, 7 (04)
[34]   Cortical correlates of speech intelligibility measured using functional near-infrared spectroscopy (fNIRS) [J].
Lawrence, Rachael J. ;
Wiggins, Ian M. ;
Anderson, Carly A. ;
Davies-Thompson, Jodie ;
Hartley, Douglas E. H. .
HEARING RESEARCH, 2018, 370 :53-64
[35]   Coregistering functional near-infrared spectroscopy with underlying cortical areas in infants [J].
Lloyd-Fox, Sarah ;
Richards, John E. ;
Blasi, Anna ;
Murphy, Declan G. M. ;
Elwell, Clare E. ;
Johnson, Mark H. .
NEUROPHOTONICS, 2014, 1 (02)
[36]   Unleashing the future potential of functional near-infrared spectroscopy in brain sciences [J].
Cutini, Simone ;
Rigadoi, Sabrina .
JOURNAL OF NEUROSCIENCE METHODS, 2014, 232 :152-156
[37]   Cerebral reactivity in migraine patients measured with functional near-infrared spectroscopy [J].
Pourshoghi, Ahmadreza ;
Danesh, Arash ;
Tabby, David Stuart ;
Grothusen, John ;
Pourrezaei, Kambiz .
EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2015, 20
[38]   Decoding semantic representations from functional near-infrared spectroscopy signals [J].
Zinszer, Benjamin D. ;
Bayet, Laurie ;
Emberson, Lauren L. ;
Raizada, Rajeev D. S. ;
Aslin, Richard N. .
NEUROPHOTONICS, 2018, 5 (01)
[39]   Functional near-infrared spectroscopy for the assessment and treatment of patients with disorders of consciousness [J].
Wang, Nan ;
He, Yifang ;
Zhu, Sipeng ;
Liu, Dongsheng ;
Chai, Xiaoke ;
He, Qiheng ;
Cao, Tianqing ;
He, Jianghong ;
Li, Jingqi ;
Si, Juanning ;
Yang, Yi ;
Zhao, Jizong .
FRONTIERS IN NEUROLOGY, 2025, 16
[40]   Classification of six sound categories using functional near-infrared spectroscopy [J].
Yoo, So-Hyeon ;
Hong, Keum-Shik .
2022 13TH ASIAN CONTROL CONFERENCE, ASCC, 2022, :1553-1557