Capacitively coupled contactless conductivity detection to account for system-induced gradient deformation in liquid chromatography
被引:6
作者:
Niezen, Leon E.
[1
,2
]
Bos, Tijmen S.
[2
,3
]
Schoenmakers, Peter J.
[1
,2
]
Somsen, Govert W.
[2
,3
]
Pirok, Bob W. J.
[1
,2
,4
]
机构:
[1] Univ Amsterdam, Vant Hoff Inst Mol Sci, Fac Sci, Analyt Chem Grp, Sci Pk 904, NL-1098 XH Amsterdam, Netherlands
[2] Ctr Analyt Sci Amsterdam CASA, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Amsterdam Inst Mol & Life Sci, Div Bioanalyt Chem, De Boelelaan 1085, NL-1081 HV Amsterdam, Netherlands
[4] Postbus 94157, NL-1090 GD Amsterdam, Netherlands
基金:
荷兰研究理事会;
关键词:
Contactless conductivity detector;
Gradient -elution liquid chromatography;
Gradient deformation;
Response functions;
Method transfer;
Instrument -independent retention parameters;
Deconvolution;
CAPILLARY-ELECTROPHORESIS;
FUNDAMENTAL-ASPECTS;
ELUTION;
SEPARATIONS;
PROFILES;
BEHAVIOR;
D O I:
10.1016/j.aca.2023.341466
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
The time required for method development in gradient-elution liquid chromatography (LC) may be reduced by using an empirical modelling approach to describe and predict analyte retention and peak width. However, prediction accuracy is impaired by system-induced gradient deformation, which can be especially prominent for steep gradients. As the deformation is unique to each LC instrument, it needs to be corrected for if retention modelling for optimization and method transfer is to become generally applicable. Such a correction requires knowledge of the actual gradient profile. The latter has been measured using capacitively coupled "contactless" conductivity detection (C4D), featuring a low detection volume (approximately 0.05 & mu;L) and compatibility with very high pressures (80 MPa or more). Several different solvent gradients, from water to acetonitrile, water to methanol, and acetonitrile to tetrahydrofuran, could be measured directly without the addition of a tracer component to the mobile phase, exemplifying the universal nature of the approach. Gradient profiles were found to be unique for each solvent combination, flowrate, and gradient duration. The profiles could be described by convoluting the programmed gradient with a weighted sum of two distribution functions. Knowledge of the exact profiles was used to improve the inter-system transferability of retention models for toluene, anthracene, phenol, emodin, sudan-I and several polystyrene standards.