High-performance ultrasonic transducer based on PZT piezoelectric ceramic for high-temperature NDE

被引:26
作者
Zou, Kai [1 ,2 ]
Yue, Qingwen [1 ]
Li, Jianan [1 ,2 ]
Zhang, Wenbin [1 ]
Liang, Ruihong [1 ,3 ]
Zhou, Zhiyong [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Ceram, Key Lab Inorgan Funct Mat & Devices, 1295 Dingxi Rd, Shanghai 200050, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Shanghai Inst Ceram, State Key Lab High Performance Ceram & Superfine M, Shanghai 200050, Peoples R China
关键词
Piezoelectric ultrasonic transducer; High temperature; PZT piezoelectric ceramic; Temperature stability; Non-destructive evaluation; THERMAL DEPOLARIZATION; FREQUENCY;
D O I
10.1016/j.ultras.2023.107013
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Piezoelectric ultrasonic transducers (PUT) are applied in a wide range of fields such as non-destructive evaluation (NDE), medical imaging and petroleum exploration, etc. Nevertheless, most PUTs cannot achieve high performance and high operating temperatures simultaneously because of the inverse correlation between piezoelectric property and operating temperature. In this paper, a high-performance ultrasonic transducer based on PZT-5A type piezoelectric ceramic (S35) for high-temperature NDE over 300 degrees C was proposed. Firstly, it is found that the d33, kp, and kt of the S35 ceramic plate show great temperature stability from 50 degrees C to 300 degrees C, which is attributed to the stabilisation of the phase structure and no occurrence of obvious depolarization behavior before the Curie temperature. And then, a single-element PUT based on S35 was fabricated, and pulseecho tests from 50 degrees C to 300 degrees C in confined heating environments were executed. The peak-to-peak value (Vpp) varies from 2.58 V to 0.753 V, which results from the increase of the permittivity of the piezoelectric element and the degradation of the acoustic contact, and the -6dB BW demonstrates excellent temperature stability with a variation less than 10%. These results indicate the great potential of this high-performance ultrasonic transducer for high-temperature NDE.
引用
收藏
页数:8
相关论文
共 39 条
[1]   Measurement of the temperature-dependent output of lead zirconate titanate transducers [J].
Bakaric, Marina ;
Fromme, Paul ;
Hurrell, Andrew ;
Rajagopal, Srinath ;
Miloro, Piero ;
Zeqiri, Bajram ;
Cox, Benjamin T. ;
Treeby, Bradley E. .
ULTRASONICS, 2021, 114
[2]   Resonance analysis of a high temperature piezoelectric disc for sensitivity characterization [J].
Bilgunde, Prathamesh N. ;
Bond, Leonard J. .
ULTRASONICS, 2018, 87 :103-111
[3]   Effect of Thermal Degradation on High Temperature Ultrasonic Transducer Performance in Small Modular Reactors [J].
Bilgunde, Prathamesh N. ;
Bond, Leonard J. .
Proceedings of the 2015 ICU International Congress on Ultrasonics, 2015, 70 :433-436
[4]   Air-coupled ultrasonic NDE: experiments in the frequency range 750 kHz-2 MHz [J].
Blomme, E ;
Bulcaen, D ;
Declercq, F .
NDT & E INTERNATIONAL, 2002, 35 (07) :417-426
[5]   Study on the bending vibration of bimorph rectangular transducer based on type 2-2 piezoelectric composites [J].
Chen, Cheng ;
Wang, Sha ;
Tian, Hua ;
Lin, Shuyu .
ULTRASONICS, 2021, 117
[6]   High-power piezoelectric characteristics of manganese-modified BiScO3-PbTiO3 high-temperature piezoelectric ceramics [J].
Chen, Jianguo ;
Hu, Zhongqiang ;
Shi, Huaduo ;
Li, Meiya ;
Dong, Shuxiang .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2012, 45 (46)
[7]   Microstructures, dielectric, and piezoelectric properties of W/Cr co-doped Bi4Ti3O12 ceramics [J].
Chen, Yu ;
Liang, Dayun ;
Wang, Qingyuan ;
Zhu, Jianguo .
JOURNAL OF APPLIED PHYSICS, 2014, 116 (07)
[8]   High-performance and high-thermally stable PSN-PZT piezoelectric ceramics achieved by high-temperature poling [J].
Chen, Zhengran ;
Liang, Ruihong ;
Zhang, Chi ;
Zhou, Zhiyong ;
Li, Yuchen ;
Liu, Zhenming ;
Dong, Xianlin .
JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2022, 116 :238-245
[9]   High-temperature ultrasonic thickness monitoring for pipe thinning in a flow-accelerated corrosion proof test facility [J].
Cheong, Yong-Moo ;
Kim, Kyung-Mo ;
Kim, Dong-Jin .
NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (07) :1463-1471
[10]   Ultrasonic transducer with BiScO3-PbTiO3-based ceramics of operating temperature over 400°C [J].
Dong, Yazhu ;
Yue, Qingwen ;
Cheng, Dongxu ;
Zhou, Zhiyong ;
Liang, Ruihong ;
Dong, Xianlin .
SENSORS AND ACTUATORS A-PHYSICAL, 2022, 340