Thermal management in legacy air-cooled data centers: An overview and perspectives

被引:14
作者
Isazadeh, Amin [1 ]
Ziviani, Davide [2 ]
Claridge, David E. [1 ]
机构
[1] Texas A&M Univ, Sch Mech Engn, Energy Syst Lab, College Stn, TX 77840 USA
[2] Purdue Univ, Sch Mech Engn, Ray W Herrick Labs, W Lafayette, IN 47907 USA
关键词
Data center; Air-cooled systems; Hard-floor design; Raised-floor design; Cold/hot aisle configuration; Aisle containment; Exhaust chimney; Evaporative cooling; Desiccant wheel; Thermal energy storage; RAISED-FLOOR; PERFORMANCE; SYSTEMS; HEAT;
D O I
10.1016/j.rser.2023.113707
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Depletion of fossil fuel reservoirs, greenhouse gas emissions' impact on global warming, and rising energy costs are pushing the data center sector to reduce energy use. This paper reviews strategies for improving the energy performance of air-cooled systems in datacom facilities and enhancing temperature and flow distribution in white space by analyzing different airflow delivery architectures (hard floor and raised floor designs), eliminating cold and hot air mixing by incorporating cold/hot aisle containment or exhaust chimneys, and potential energy savings achievable by utilizing evaporative cooling systems. It was found that the optimal ventilation system is hard-floor architecture with locally-ducted supply and return air. Hard floor is less complicated than raised floor design, and overhead supply air can minimize hot spots at the top of racks. Airflow management strategies including cold and hot aisle formation, aisle containment, and exhaust chimneys can reduce annual cooling energy usage by 10-50% in conjunction with air-side and water-side economizers, minimize hot spots, and enhance thermal performance during cooling system failure. Hot-Aisle Containment or exhaust chimneys provide better thermal and energy performance than open and/or cold-aisle containment, but they require new ducting in traditional data centers. Depending on the climate and geographical location, evaporative cooling can reduce annual cooling energy usage by 20-70% and lead to Power Usage Effectiveness as low as 1.06. Evaporative coolers are more suitable for dry climates, but this limitation can be ameliorated by incorporating desiccant wheels and thermal energy storage.
引用
收藏
页数:18
相关论文
共 75 条
  • [21] Evans T, 2012, Schneider Electr. White Pap. 59, P2
  • [22] Advances in data center thermal management
    Fulpagare, Yogesh
    Bhargav, Atul
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 43 : 981 - 996
  • [23] George Kamiya, 2020, Data centres and data transmission networks
  • [24] A review on evaluation metrics of thermal performance in data centers
    Gong, Xiaoming
    Zhang, Zhongbin
    Gan, Sixuan
    Niu, Baolian
    Yang, Liu
    Xu, Haijin
    Gao, Manfang
    [J]. BUILDING AND ENVIRONMENT, 2020, 177
  • [25] A parametric study of an indirect evaporative air cooler
    Guo, XC
    Zhao, TS
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1998, 25 (02) : 217 - 226
  • [26] Impact of aisle containment on energy performance of a data center when using an integrated water-side economizer
    Ham, Sang-Woo
    Jeong, Jae-Weon
    [J]. APPLIED THERMAL ENGINEERING, 2016, 105 : 372 - 384
  • [27] A review of data centers as prosumers in district energy systems: Renewable energy integration and waste heat reuse for district heating
    Huang, Pei
    Copertaro, Benedetta
    Zhang, Xingxing
    Shen, Jingchun
    Lofgren, Isabelle
    Ronnelid, Mats
    Fahlen, Jan
    Andersson, Dan
    Svanfeldt, Mikael
    [J]. APPLIED ENERGY, 2020, 258
  • [28] Internet World Stats, 2022, Internet growth statistics
  • [29] Isazadeh A, 2022, 19 INT REFRIGERATION, P2492
  • [30] Global trends, performance metrics, and energy reduction measures in datacom facilities
    Isazadeh, Amin
    Ziviani, Davide
    Claridge, David E.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2023, 174