A high-efficiency gas-liquid coupled heat-driven thermoacoustic heat pump

被引:12
|
作者
Chi, Jiaxin [1 ,2 ]
Xiao, Lei [1 ,2 ]
Wu, Zhanghua [1 ]
Xu, Jingyuan [3 ]
Yang, Yupeng [1 ,2 ]
Hu, Yiwei [1 ,2 ]
Zhang, Liming [1 ]
Hu, Jianying [1 ]
Luo, Ercang [1 ,2 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Karlsruhe Inst Technol, Mech & Elect Engn Div, D-76344 Karlsruhe, Germany
基金
中国国家自然科学基金;
关键词
Thermoacoustic; Heat pump; Heat-driven; Gas-liquid coupled resonator; REFRIGERATOR; ENGINE;
D O I
10.1016/j.ijrefrig.2023.08.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
The search for a diversified and sustainable technology for energy utilisation is crucial for reducing the consumption of fossil energy. This research proposed a novel heat-driven thermoacoustic heat pump with a gas-liquid coupled resonator that exhibits high efficiency, compact structure and easy fabrication. A series of theoretical and experimental studies has been performed in this work, including numerical and experimental domestic heating performance, onset characteristics as well as the effects of different liquid masses and high and ambient temperatures on the performance of a heat pump. Results show that the theoretical and experimental heat pump performance exhibit good agreement, with a standard error of about 5%. Moreover, the gas-liquid coupled heat-driven thermoacoustic heat pump has a low onset temperature (70 degrees C at 3 MPa), offering a wide range of applications for low-grade thermal energy utilisation. With high, ambient and domestic heating temperatures of 300 degrees C, 10 degrees C and 50 degrees C, respectively, a maximum domestic heating power of 18.4 kW is obtained, corresponding to the maximum coefficient of performance of domestic heating based on heating power (COPh) of 1.48. Furthermore, a maximum relative Carnot efficiency of 50.9% and a COPh of 1.31 with a hot-end temperature of 300 degrees C are achieved under ambient and domestic heating temperatures of -20 degrees C and 50 degrees C, respectively. These results present a new domestic heating approach for the utilisation of medium- and low-grade thermal energy.
引用
收藏
页码:296 / 304
页数:9
相关论文
共 50 条
  • [41] Novel design of a high efficiency multi-bed active magnetic regenerator heat pump
    Dall'Olio, S.
    Masche, M.
    Liang, J.
    Insinga, A. R.
    Eriksen, D.
    Bjork, R.
    Nielsen, K. K.
    Barcza, A.
    Vieyra, H. A.
    Beek, Niels, V
    Bez, H. Neves
    Engelbrecht, K.
    Bahl, C. R. H.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 132 : 243 - 254
  • [42] Gas engine driven heat pump - characteristics, analysis of applications in buildings energy systems
    Rucinski, Adam
    Rusowicz, Artur
    Grzebielec, Andrzej
    9TH INTERNATIONAL CONFERENCE ENVIRONMENTAL ENGINEERING (9TH ICEE) - SELECTED PAPERS, 2014,
  • [43] Exergoeconomic analyses of a gas engine driven heat pump drier and food drying process
    Gungor, Aysegul
    Erbay, Zafer
    Hepbasli, Arif
    APPLIED ENERGY, 2011, 88 (08) : 2677 - 2684
  • [44] Analysis on a single-stage direct-coupled thermoacoustic refrigerator driven by low/medium-grade heat
    Hu, Yiwei
    Xu, Jingyuan
    Zhao, Dan
    Yang, Rui
    Hu, Jianying
    Luo, Ercang
    APPLIED ENERGY, 2024, 361
  • [45] Optimization of solution concentration in liquid desiccant air-conditioning system driven by heat pump
    Guan, Bowen
    Liu, Xiaohua
    Zhang, Tao
    ENERGY AND BUILDINGS, 2020, 225
  • [46] Performance investigation of a counter-flow heat pump driven liquid desiccant dehumidification system
    Xie, Ying
    Zhang, Tao
    Liu, Xiaohua
    ENERGY, 2016, 115 : 446 - 457
  • [47] Design of heat pump-driven liquid desiccant air conditioning systems for residential building
    Lee, Jae-Hee
    Ko, Jin-Young
    Jeong, Jae-Weon
    APPLIED THERMAL ENGINEERING, 2021, 183
  • [48] Miniaturization of the Loop-Tube-Type Thermoacoustic Cooling System: Effect of the Installation Position of Heat Pump and Working Gas in the Tube
    Hotta, Kohei
    Sakamoto, Shin-ichi
    Tsukamoto, Daichi
    Watanabe, Yoshiaki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (07)
  • [49] The role of pumped and waste heat technologies in a high-efficiency sustainable energy future for the UK
    Markides, Christos N.
    APPLIED THERMAL ENGINEERING, 2013, 53 (02) : 197 - 209
  • [50] Performance assessment of a natural gas expansion plant integrated with a vertical ground-coupled heat pump
    Ghezelbash, Reza
    Farzaneh-Gord, Mahmood
    Behi, Hamidreza
    Sadi, Meisam
    Khorramabady, Heshmatollah Shams
    ENERGY, 2015, 93 : 2503 - 2517