A high-efficiency gas-liquid coupled heat-driven thermoacoustic heat pump

被引:12
|
作者
Chi, Jiaxin [1 ,2 ]
Xiao, Lei [1 ,2 ]
Wu, Zhanghua [1 ]
Xu, Jingyuan [3 ]
Yang, Yupeng [1 ,2 ]
Hu, Yiwei [1 ,2 ]
Zhang, Liming [1 ]
Hu, Jianying [1 ]
Luo, Ercang [1 ,2 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Karlsruhe Inst Technol, Mech & Elect Engn Div, D-76344 Karlsruhe, Germany
基金
中国国家自然科学基金;
关键词
Thermoacoustic; Heat pump; Heat-driven; Gas-liquid coupled resonator; REFRIGERATOR; ENGINE;
D O I
10.1016/j.ijrefrig.2023.08.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
The search for a diversified and sustainable technology for energy utilisation is crucial for reducing the consumption of fossil energy. This research proposed a novel heat-driven thermoacoustic heat pump with a gas-liquid coupled resonator that exhibits high efficiency, compact structure and easy fabrication. A series of theoretical and experimental studies has been performed in this work, including numerical and experimental domestic heating performance, onset characteristics as well as the effects of different liquid masses and high and ambient temperatures on the performance of a heat pump. Results show that the theoretical and experimental heat pump performance exhibit good agreement, with a standard error of about 5%. Moreover, the gas-liquid coupled heat-driven thermoacoustic heat pump has a low onset temperature (70 degrees C at 3 MPa), offering a wide range of applications for low-grade thermal energy utilisation. With high, ambient and domestic heating temperatures of 300 degrees C, 10 degrees C and 50 degrees C, respectively, a maximum domestic heating power of 18.4 kW is obtained, corresponding to the maximum coefficient of performance of domestic heating based on heating power (COPh) of 1.48. Furthermore, a maximum relative Carnot efficiency of 50.9% and a COPh of 1.31 with a hot-end temperature of 300 degrees C are achieved under ambient and domestic heating temperatures of -20 degrees C and 50 degrees C, respectively. These results present a new domestic heating approach for the utilisation of medium- and low-grade thermal energy.
引用
收藏
页码:296 / 304
页数:9
相关论文
共 50 条
  • [21] A highly efficient heat-driven thermoacoustic system for room-temperature refrigeration by using novel configuration
    Luo, Kaiqi
    Luo, Ercang
    Xie, Xiaoyun
    Jiang, Yi
    APPLIED ENERGY, 2024, 357
  • [22] Simulation of thermoacoustic heat pump effects driven by acoustic radiation in a cavity flow
    Yokoyama, Hiroshi
    Omori, Yasuaki
    Kume, Masashi
    Nishikawara, Masahito
    Yanada, Hideki
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 185
  • [23] Thermodynamic analysis of a hybrid gas turbine/thermoacoustic heat pump/refrigeration engine
    Ghorbanian, K.
    Karimi, M.
    INTERNATIONAL JOURNAL OF EXERGY, 2014, 15 (02) : 152 - 170
  • [24] Energy analysis of gas engine driven heat pump
    Jiang, Ning
    Gao, Zengliang
    MECHANICAL AND ELECTRONICS ENGINEERING III, PTS 1-5, 2012, 130-134 : 771 - 774
  • [25] Study on a novel looped heat-driven thermoacoustic refrigerator with direct-coupling configuration for room temperature cooling
    Wang, Huizhi
    Zhang, Limin
    Hu, Jianying
    Yu, Guoyao
    Wu, Zhanghua
    Dai, Wei
    Luo, Ercang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 123 : 180 - 188
  • [26] Travelling-wave thermoacoustic high-temperature heat pump for industrial waste heat recovery
    Yang, Zhao
    Zhuo, Yang
    Ercang, Luo
    Yuan, Zhou
    ENERGY, 2014, 77 : 397 - 402
  • [27] Numerical simulation of liquid desiccant evaporator driven by heat pump
    Niu Run-ping
    Chen Xiao-yi
    Wang Zi-ye
    Kuang Da-qing
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2019, 26 (08) : 2197 - 2213
  • [28] Conception of combination of gas-engine-driven heat pump and water-loop heat pump system
    Lian, ZW
    Park, SR
    Huang, W
    Baik, YJ
    Yao, Y
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (06): : 810 - 819
  • [29] Design and Thermodynamic Analysis of Waste Heat-Driven Zeolite-Water Continuous-Adsorption Refrigeration and Heat Pump System for Ships
    Ezgi, Cuneyt
    ENERGIES, 2021, 14 (03)
  • [30] A high-efficiency liquid hydrogen storage system cooled by a fuel-cell-driven refrigerator for hydrogen combustion heat recovery
    Xu, Xiafan
    Xu, Hao
    Zheng, Jianpeng
    Chen, Liubiao
    Wang, Junjie
    ENERGY CONVERSION AND MANAGEMENT, 2020, 226