Flat panel CT versus multidetector CT in skull base imaging: are there differences in image quality?

被引:1
作者
Schulze, Maximilian [1 ,2 ]
Hirt, Bernhard [3 ]
Reimann, Katrin [4 ,5 ]
机构
[1] Univ Tubingen, Dept Neuroradiol, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Philipps Univ Marburg, Univ Hosp Marburg, Dept Neuroradiol, Baldingerstr, D-35043 Marburg, Germany
[3] Univ Tubingen, Inst Clin Anat & Cell Anal, Elfriede-Aulhorn-Str 8, D-72076 Tubingen, Germany
[4] Univ Tubingen, Dept Otolaryngol Head & Neck Surg, Elfriede-Aulhorn-Str 5, D-72076 Tubingen, Germany
[5] Philipps Univ Marburg, Dept Otolaryngol Head & Neck Surg, Baldingerstr, D-35043 Marburg, Germany
关键词
Flat panel computed tomography; Multidetector computed tomography; Skull base; Image quality; MULTISLICE COMPUTED-TOMOGRAPHY; CONE-BEAM CT; DETECTOR-ROW; RECONSTRUCTION; ACQUISITION; MAXILLARY; SURGERY; FORAMEN; SINUS;
D O I
10.1186/s13005-023-00391-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundPurpose of this study was to compare image quality of the skull base in standard 20s protocol flat panel computed tomography (FPCT) with the new time and dose improved 10s protocol as well as with 128 slice multidetector computed tomography (MDCT).Methods10 whole skull preparations were scanned with either 128 slice MDCT(SOMATOM Definition AS+, Siemens, Erlangen) or FPCT (AXIOM-Artis, Siemens, Erlangen) using 10s or 20s protocol.ResultsFPCT provides significantly better image quality and improved delimitation of clinically relevant structures in the anterior, temporal and posterior skull base compared to 128 slice MDCT. The 20s FPCT protocol yielded best delimitability of evaluated skull base structures. However, the shorter, dose saving 10s FPCT protocol was still significantly superior to 128 slice MDCT regarding delimitability of skull base structures and additionally showed no significant inferiority compared with the 20s FPCT protocol.ConclusionsThe 10s FPCT protocol yields a significantly better image quality at a comparable radiation dose exposure in imaging skull base structures compared to MDCT.Trial registration371/2017BO2.
引用
收藏
页数:10
相关论文
共 28 条
[1]   Large scan field, high spatial resolution flat-panel detector based volumetric CT of the whole human skull base and for maxillofacial imaging [J].
Bartling, S. H. ;
Majdani, O. ;
Gupta, R. ;
Rodt, T. ;
Dullin, C. ;
Fitzgerald, P. F. ;
Becker, H. .
DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (06) :317-327
[2]   Increase of accuracy in intraoperative navigation through high-resolution flat-panel volume computed tomography: Experimental comparison with multislice computed tomography-based navigation [J].
Bartling, Soenke H. ;
Leinung, Martin ;
Graute, Johannes ;
Rodt, Thomas ;
Dullin, Christian ;
Becker, Hartmut ;
Lenarz, Thomas ;
Stover, Timo ;
Majdani, Omid .
OTOLOGY & NEUROTOLOGY, 2007, 28 (01) :129-134
[3]   Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses [J].
Bozzato, Alessandro ;
Struffert, Tobias ;
Hertel, Victoria ;
Iro, Heinrich ;
Hornung, Joachim .
EUROPEAN RADIOLOGY, 2010, 20 (03) :566-571
[4]   Intraoperative computed tomography as reliable navigation registration device in 200 cranial procedures [J].
Carl, Barbara ;
Bopp, Miriam ;
Sass, Benjamin ;
Nimsky, Christopher .
ACTA NEUROCHIRURGICA, 2018, 160 (09) :1681-1689
[5]   Comparison of Intraoperative Portable CT Scanners in Skull Base and Endoscopic Sinus Surgery: Single Center Case Series [J].
Conley, David B. ;
Tan, Bruce ;
Bendok, Bernard R. ;
Batjer, H. Hunt ;
Chandra, Rakesh ;
Sidle, Douglas ;
Rahme, Rudy J. ;
Adel, Joseph G. ;
Fishman, Andrew J. .
SKULL BASE-AN INTERDISCIPLINARY APPROACH, 2011, 21 (04) :261-270
[6]   MSCT versus CBCT: evaluation of high-resolution acquisition modes for dento-maxillary and skull-base imaging [J].
Dillenseger, Jean-Philippe ;
Matern, Jean-Francois ;
Gros, Catherine-Isabelle ;
Bornert, Fabien ;
Goetz, Christian ;
Le Minor, Jean-Marie ;
Constantinesco, Andre ;
Choquet, Philippe .
EUROPEAN RADIOLOGY, 2015, 25 (02) :505-515
[7]   Intraventricular and Skull Base Neuroendoscopy in 2012: A Global Survey of Usage Patterns and the Role of Intraoperative Neuronavigation [J].
Esposito, Felice ;
Di Rocco, Federico ;
Zada, Gabriel ;
Cinalli, Giuseppe ;
Schroeder, Henry W. S. ;
Mallucci, Conor ;
Cavallo, Luigi M. ;
Decq, Philippe ;
Chiaramonte, Carmela ;
Cappabianca, Paolo .
WORLD NEUROSURGERY, 2013, 80 (06) :709-716
[8]   Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT [J].
Flohr, T. G. ;
Stierstorfer, K. ;
Suess, C. ;
Primak, A. N. ;
McCollough, C. H. .
MEDICAL PHYSICS, 2007, 34 (05) :1712-1723
[9]   Computed tomography dose assessment for a 160 mm wide, 320 detector row, cone beam CT scanner [J].
Geleijns, J. ;
Artells, M. Salvado ;
Bruin, P. Wde ;
Matter, R. ;
Muramatsu, Y. ;
McNitt-Gray, M. F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (10) :3141-3159
[10]   Multi-Detector-Row Computed Tomography Imaging of Variant Skull Base Foramina [J].
Ginat, Daniel Thomas ;
Ellika, Shehanaz K. ;
Corrigan, John .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) :481-485