Investigation of temperature effects on the ageing of paper-oil insulation under repetitive transient voltages

被引:1
|
作者
Arabul, Ahmet Yigit [1 ,2 ]
Arabul, Fatma Keskin [1 ,2 ]
Jayaram, Shesha H. [1 ]
机构
[1] Univ Waterloo, Elect & Comp Engn, Waterloo, ON, Canada
[2] Yildiz Tech Univ, Dept Elect Engn, Istanbul, Turkiye
基金
加拿大自然科学与工程研究理事会;
关键词
windfarm; step-up transformer; paper-oil insulation; repetitive transient; ageing; turn-to-turn insulation;
D O I
10.1109/EIC55835.2023.10177299
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, the effects of temperature over a range of 20 - 100 degrees C on paper-oil insulation under repetitive transient voltages have been analyzed. The ageing of the paper-oil insulation is measured based on the dielectric frequency response, partial discharge inception voltage, and intensity of discharges. The Luminol (TM) TRi oil, considering its oxidation stability and negative index for gassing has been selected as test oil to evaluate its applicability as an alternative liquid insulation for transformers facing continuous high-frequency repetitive transient voltages. The results help in understanding the ageing response of turn-to-turn insulation in wind-turbine step-up transformers subjected to repetitive transient voltages at different operating temperatures.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] The assessment of the influence of temperature of selected parameters of the approximation method of depolarization current analysis of paper-oil insulation
    Wolny, Stefan
    Kedzia, Jozef
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2010, 356 (11-17) : 809 - 814
  • [22] DIELECTRIC STRENGTH OF PAPER-OIL INSULATION ACTED ON BY dc VOLTAGE.
    Butkevich, V.G.
    Lokhanin, A.K.
    Ponomarenko, V.N.
    1978, 49 (04): : 47 - 52
  • [23] Application of Aging Studies to the Evaluation of Paper-Oil Insulation of Power Capacitors.
    Buck, Jozef
    Przeglad Elektrotechniczny, 1972, 48 (10): : 452 - 455
  • [24] Model building for current transformer paper-oil insulation state diagnostics
    Skrupskaya, L. S.
    Oliinyk, A. O.
    Sakhno, A. A.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2014, (02) : 48 - 51
  • [25] Structure of Paper-Oil Insulation for Mass-Impregnated HVDC Cables
    Hakonseth, G.
    Furuheim, K. M.
    Ildstad, E.
    2019 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2019, : 524 - 527
  • [26] Effects of Direct Fluorination on Charge Coupling Behavior of Oil-paper Insulation under DC and Pulse Voltages
    Du, B. X.
    Zhu, W. B.
    Li, X. L.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (02) : 947 - 955
  • [27] Diagnostics of the paper-oil insulation condition using selected parameters of recovery voltage
    Wolny, Stefan
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (10): : 214 - 217
  • [28] Influence of Temperature, Moisture Content and Ageing on Oil Impregnated Paper Bushings Insulation
    Mikulecky, Antun
    Stih, Zeljko
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (04) : 1421 - 1427
  • [29] Charge Transport in Oil Impregnated Paper Insulation Under Temperature Gradient Using Transient Upstream FEM
    Jin, Shuo
    Ruan, Jiangjun
    Du, Zhiye
    Yang, Zhifei
    Zhou, Taotao
    Huang, Guodong
    Zhu, Lin
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2015, 1 (03): : 3 - 9
  • [30] Modeling of Early Stage Partial Discharge and Overheating Degradation of Paper-oil Insulation
    Tsuchie, Motoo
    Kozako, Masahiro
    Hikita, Masayuki
    Sasaki, Ei
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (03) : 1342 - 1349