Investigation of temperature effects on the ageing of paper-oil insulation under repetitive transient voltages

被引:1
|
作者
Arabul, Ahmet Yigit [1 ,2 ]
Arabul, Fatma Keskin [1 ,2 ]
Jayaram, Shesha H. [1 ]
机构
[1] Univ Waterloo, Elect & Comp Engn, Waterloo, ON, Canada
[2] Yildiz Tech Univ, Dept Elect Engn, Istanbul, Turkiye
基金
加拿大自然科学与工程研究理事会;
关键词
windfarm; step-up transformer; paper-oil insulation; repetitive transient; ageing; turn-to-turn insulation;
D O I
10.1109/EIC55835.2023.10177299
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, the effects of temperature over a range of 20 - 100 degrees C on paper-oil insulation under repetitive transient voltages have been analyzed. The ageing of the paper-oil insulation is measured based on the dielectric frequency response, partial discharge inception voltage, and intensity of discharges. The Luminol (TM) TRi oil, considering its oxidation stability and negative index for gassing has been selected as test oil to evaluate its applicability as an alternative liquid insulation for transformers facing continuous high-frequency repetitive transient voltages. The results help in understanding the ageing response of turn-to-turn insulation in wind-turbine step-up transformers subjected to repetitive transient voltages at different operating temperatures.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Accelerated Ageing Study of Transformer Paper-oil Insulation under Repetitive Transient Conditions
    Devadiga, A. A.
    Jayaram, S. H.
    2022 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP 2022), 2022, : 61 - 64
  • [2] ELECTRICAL BREAKDOWN STRENGTH OF PAPER-OIL INSULATION UNDER PULSATING VOLTAGES
    NOWACZYK, H
    GRZYBOWSKI, S
    KUFFEL, E
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1987, 22 (03): : 249 - 253
  • [3] Study of anomalous breakdown of paper-oil insulation under unconventional voltages
    Viswanatha, C.
    Rajan, J.Sundara
    Dwarakanath, K.
    Nema, R.S.
    IEEE International Conference on Conduction and Breakdown in Dielectric Liquids, ICDL, 1999, : 219 - 222
  • [4] ELECTRICAL STRENGTH OF PAPER-OIL INSULATION SUBJECTED TO COMPOSITE VOLTAGES
    MOSINSKI, F
    WODZINSKI, J
    SIKORSKI, L
    ZIENCIKIEWICZ, J
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1994, 1 (04) : 615 - 623
  • [5] Assessment of moisture contents in paper-oil insulation with advanced ageing processes
    Szrot, Marek
    Subocz, Jan
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (11B): : 170 - 173
  • [6] Ageing studies on paper-oil to assess the condition of solid insulation used in Power Transformers
    Thomas, P
    Shukla, AK
    Raghuveer
    ICSD '01: PROCEEDINGS OF THE 2001 IEEE 7TH INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, 2001, : 69 - 72
  • [7] Comparative evaluation of dielectric strength of paper-oil insulation under ac, dc, combined, composite ac/dc and impulse voltages
    Rajan, JS
    Dwarakanath, K
    Moorching, SN
    1998 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 1998, : 236 - 239
  • [8] PAPER-OIL INSULATION - NEW DEFINITION OF DAMAGE
    ASENJO, E
    EIDELSTEIN, G
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1978, 13 (03): : 179 - 183
  • [9] A Field Study of Aging in Paper-Oil Insulation Systems
    Lelekakis, Nick
    Guo, Wenyu
    Martin, Daniel
    Wijaya, Jaury
    Susa, Dejan
    IEEE ELECTRICAL INSULATION MAGAZINE, 2012, 28 (01) : 12 - 19
  • [10] Influence of sludge on electric processes in paper-oil insulation
    Zenker, Marek
    Mrozik, Andrzej
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (11B): : 334 - 336