Performance evaluation of a novel heat pump system for drying with EVI-compressor driven precooling and reheating

被引:9
作者
Cheng, Jia-Hao [1 ]
Cao, Xiang [1 ]
Shao, Liang-Liang [1 ]
Zhang, Chun-Lu [1 ]
机构
[1] Tongji Univ, Inst Refrigerat & Cryogen, Sch Mech Engn, Shanghai 201804, Peoples R China
基金
中国国家自然科学基金;
关键词
Heat pump drying; Enhanced vapor injection; Precooling; Reheating; Exergetic analysis; Economic analysis; DEHUMIDIFIER;
D O I
10.1016/j.energy.2023.127989
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat pump drying is widely used in the agricultural and industrial sectors. This study proposes a novel heat pump system for closed-loop drying, which employs an enhanced vapor injection (EVI) compressor (HPDEVI). The system precools the return air to a closer-to-saturation state to enhance dehumidification and reheats the dehumidified cold air while increasing the refrigerant subcooling. Meanwhile, EVI is fulfilled to modify the heat pump cycle. To demonstrate its superiority, the HPDEVI's energetic, exergetic and economic performances are compared to those of the basic configuration (HPDbasic) and the system with a stand-alone heat pipe (HPDHP). The results show that HPDEVI outperforms the other two systems by increasing latent heat ratio of evaporator, compressor isentropic efficiency and refrigerant subcooling. Under the design condition (Tdb = 45 degrees C, RH = 40%), HPDEVI reaches a specific moisture extraction rate (SMER) of 3.07 kg/kWh and a moisture extraction rate (MER) of 43.8 kg/h. These values are increased by 16.7% and 12.9% compared to HPDbasic, and 8.9% and 4.5% relative to HPDHP, respectively. Moreover, HPDEVI generates the lowest exergy destruction per latent heat of water removal at 0.367 W/W, and costs only 0.267 CNY per litre of water extracted after ten years of operation. Finally, the performance improvements of HPDEVI under off-design conditions are also revealed.
引用
收藏
页数:17
相关论文
共 42 条
[1]   Development of heat pump and infrared-convective dryer and performance analysis for stale bread drying [J].
Aktas, Mustafa ;
Sevik, Seyfi ;
Aktekeli, Burak .
ENERGY CONVERSION AND MANAGEMENT, 2016, 113 :82-94
[2]  
[Anonymous], 2020, AIR CONDITIONING
[3]   INFLUENCE OF ENHANCING FEATURES ON DEHUMIDIFIER PERFORMANCE - LABORATORY MEASUREMENTS [J].
BANNISTER, P ;
CARRINGTON, CG ;
LIU, Q .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1995, 19 (05) :397-406
[4]  
Bejan A, 1995, Thermal design and optimization
[5]   Exergetic analysis of different R744 heat pump tumble dryer system topologies [J].
Brandt, Niklas ;
Alpoegger, Thomas ;
Tegethoff, Wilhelm ;
Bockholt, Marcos ;
Moehlenkamp, Andreas ;
Koehler, Juergen .
APPLIED THERMAL ENGINEERING, 2019, 161
[6]  
Brundett G.W., 1987, Handbook of Dehumidification Technology, P202, DOI [10.1016/B978-0-408-02520-1.50013-8, DOI 10.1016/B978-0-408-02520-1.50013-8]
[7]   Process simulation and analysis of a closed-loop heat pump clothes dryer [J].
Cao, Xiang ;
Zhang, Jing ;
Li, Zhen-Yu ;
Shao, Liang-Liang ;
Zhang, Chun-Lu .
APPLIED THERMAL ENGINEERING, 2021, 199
[8]   A novel packaged outdoor air dehumidifier with exhaust air heat pump Experiment and simulation [J].
Cao, Xiang ;
Yang, Chen ;
Sun, Zhao ;
Lu, Yue-Ming ;
Chang, Meng-Meng ;
Shao, Liang-Liang ;
Zhang, Chun-Lu .
APPLIED THERMAL ENGINEERING, 2020, 181
[9]   Stepped pressure cycle - A new approach to Lorenz cycle [J].
Cao, Xiang ;
Zhang, Chun-Lu ;
Zhang, Zi-Yang .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 74 :283-294
[10]   PERFORMANCE ANALYSIS OF A DEHUMIDIFIER USING HFC134A [J].
CARRINGTON, CG ;
BANNISTER, P ;
LIU, Q .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (07) :477-485