Tubridge flow diverter for the treatment of small and medium aneurysms

被引:5
|
作者
Xie, Dajiang [1 ,2 ]
Yang, Heng [1 ]
Zhao, Li [3 ]
Ye, Xin [2 ]
Yang, Shuxu [2 ]
Gao, Chao [1 ]
Tian, Yanlong [1 ]
Ni, Wei [1 ]
Gu, Yuxiang [1 ]
机构
[1] Fudan Univ, Huashan Hosp, Shanghai Med Coll, Dept Neurosurg, Shanghai, Peoples R China
[2] Zhejiang Univ, Sir Run Run Shaw Hosp, Coll Med Sci, Dept Neurosurg, Hangzhou, Peoples R China
[3] Zhejiang Chinese Med Univ, Hangzhou Red Cross Hosp, Integrated Tradit Chinese & Western Med Hosp Zheji, Dept Gastroenterol, Hangzhou, Peoples R China
来源
FRONTIERS IN NEUROLOGY | 2023年 / 14卷
基金
中国国家自然科学基金;
关键词
Tubridge; flow diverter; small aneurysm; medium aneurysm; tandem aneurysm; INTRACRANIAL ANEURYSMS;
D O I
10.3389/fneur.2023.1054631
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BackgroundTubridge flow diverter is a widely used device aimed at reconstructing parent arteries and occluding complex aneurysms in China. The experience of Tubridge in treating small and medium aneurysms is still limited. In this study, we aimed to evaluate the safety and efficacy of the Tubridge flow diverter for the treatment of the two types of aneurysms. MethodsWe reviewed the clinical records of aneurysms treated with a Tubridge flow diverter between 2018 and 2021 in a national cerebrovascular disease center. Cases were divided into small and medium aneurysms according to aneurysm size. The therapeutic process, occlusion rate, and clinical outcome were compared. ResultsIn total, 57 patients and 77 aneurysms were identified. The patients were divided into two groups: small aneurysms (39 patients, 54 aneurysms) and medium aneurysms (18 patients, 23 aneurysms). There were 19 patients with tandem aneurysms (a total of 39 aneurysms) in the two groups, among which 15 patients (30 aneurysms) were in the small aneurysm group and four patients (nine aneurysms) were in the medium aneurysm group. The results show that the mean maximal diameter/neck in the small and medium aneurysms was 3.68/3.25 and 7.61/6.24 mm, respectively. In total, 57 Tubridge flow diverters were successfully implanted without unfolding failure, and there were six patients with new mild cerebral infarction in the small aneurysm group. The complete occlusion rate on the last angiographic follow-up was achieved in 88.46% of the small aneurysms group and 81.82% of the medium aneurysms group. The complete occlusion rate of patients with tandem aneurysms in the last angiographic follow-up was 86.67% (13/15) of the small aneurysms group and 50% (2/4) of the medium aneurysm group. Intracranial hemorrhage was nonencountered in the two groups. ConclusionOur preliminary experience suggests that the Tubridge flow diverter might be a safe and effective treatment for small and medium aneurysms along the internal carotid artery. Long stents may increase the risk of cerebral infarction. Adequate evidence is required to clarify the definite indications and complications in a multicenter randomized controlled trial with a long-term follow-up.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Flow Diverter Stents in the Treatment of Cerebral Aneurysms Less than 5 mm
    Akgul, Erol
    Onan, Hasan Bilen
    Bilgin, Sabriye Sennur
    Tahta, Alican
    Khanmammadov, Elmir
    Gungoren, Fatma Zeynep
    Ertan, Gulhan
    Erol, Cengiz
    Sekerci, Zeki
    TURKISH NEUROSURGERY, 2021, 31 (01) : 31 - 37
  • [42] Flow diverter for the treatment of large (> 10 mm) vertebral artery dissecting aneurysms
    Woosung Lee
    Hyun Jin Han
    Junhyung Kim
    Keun Young Park
    Yong Bae Kim
    Chang Ki Jang
    Joonho Chung
    Acta Neurochirurgica, 2022, 164 : 1247 - 1254
  • [43] The Artisse Intrasaccular Device: A New Intrasaccular Flow Diverter for the Treatment of Cerebral Aneurysms
    Hecker, Constantin
    Hufnagl, Clemens
    Oellerer, Andreas
    Griessenauer, Christoph J.
    Killer-Oberpfalzer, Monika
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2025, 46 (01) : 84 - 89
  • [44] Hemodynamic analysis for endovascular treatment in small unruptured intracranial aneurysms: a matched comparison study of flow diverter versus LVIS
    Liu Jian
    Li Wenqiang
    Zhang Yisen
    Wang Kun
    Yang Xinjian
    Zhang Ying
    中华神经外科杂志(英文), 2022, 08 (02) : 73 - 81
  • [45] Hemodynamic analysis for endovascular treatment in small unruptured intracranial aneurysms: a matched comparison study of flow diverter versus LVIS
    Liu J.
    Li W.
    Zhang Y.
    Wang K.
    Yang X.
    Zhang Y.
    Chinese Neurosurgical Journal, 7 (1)
  • [46] SILK flow diverter for treatment of intracranial aneurysms: initial experience and cost analysis
    Shankar, Jai Jai Shiva
    Vandorpe, Robert
    Pickett, Gwynedd
    Maloney, William
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 : III11 - III15
  • [47] Robotically assisted deployment of flow diverter stents for the treatment of cerebral and cervical aneurysms
    Chivot, Cyril
    Bouzerar, Roger
    Peltier, Johann
    Lefranc, Michel
    Yzet, Thierry
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024, 16 (04) : 412 - 417
  • [48] Delayed ipsilateral parenchymal hemorrhage following treatment of intracranial aneurysms with flow diverter
    Catherine Tomas
    Azzedine Benaissa
    Denis Herbreteau
    Krzysztof Kadziolka
    Laurent Pierot
    Neuroradiology, 2014, 56 : 155 - 161
  • [49] Delayed ipsilateral parenchymal hemorrhage following treatment of intracranial aneurysms with flow diverter
    Tomas, Catherine
    Benaissa, Azzedine
    Herbreteau, Denis
    Kadziolka, Krzysztof
    Pierot, Laurent
    NEURORADIOLOGY, 2014, 56 (02) : 155 - 161
  • [50] Flow Diverter Stents for the Treatment of Anterior Cerebral Artery Aneurysms: Safety and Effectiveness
    Clarencon, F.
    Di Maria, F.
    Gabrieli, J.
    Shotar, E.
    Zeghal, C.
    Nouet, A.
    Chiras, J.
    Sourour, N. -A.
    CLINICAL NEURORADIOLOGY, 2017, 27 (01) : 51 - 56