Tubridge flow diverter for the treatment of small and medium aneurysms

被引:5
|
作者
Xie, Dajiang [1 ,2 ]
Yang, Heng [1 ]
Zhao, Li [3 ]
Ye, Xin [2 ]
Yang, Shuxu [2 ]
Gao, Chao [1 ]
Tian, Yanlong [1 ]
Ni, Wei [1 ]
Gu, Yuxiang [1 ]
机构
[1] Fudan Univ, Huashan Hosp, Shanghai Med Coll, Dept Neurosurg, Shanghai, Peoples R China
[2] Zhejiang Univ, Sir Run Run Shaw Hosp, Coll Med Sci, Dept Neurosurg, Hangzhou, Peoples R China
[3] Zhejiang Chinese Med Univ, Hangzhou Red Cross Hosp, Integrated Tradit Chinese & Western Med Hosp Zheji, Dept Gastroenterol, Hangzhou, Peoples R China
来源
FRONTIERS IN NEUROLOGY | 2023年 / 14卷
基金
中国国家自然科学基金;
关键词
Tubridge; flow diverter; small aneurysm; medium aneurysm; tandem aneurysm; INTRACRANIAL ANEURYSMS;
D O I
10.3389/fneur.2023.1054631
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BackgroundTubridge flow diverter is a widely used device aimed at reconstructing parent arteries and occluding complex aneurysms in China. The experience of Tubridge in treating small and medium aneurysms is still limited. In this study, we aimed to evaluate the safety and efficacy of the Tubridge flow diverter for the treatment of the two types of aneurysms. MethodsWe reviewed the clinical records of aneurysms treated with a Tubridge flow diverter between 2018 and 2021 in a national cerebrovascular disease center. Cases were divided into small and medium aneurysms according to aneurysm size. The therapeutic process, occlusion rate, and clinical outcome were compared. ResultsIn total, 57 patients and 77 aneurysms were identified. The patients were divided into two groups: small aneurysms (39 patients, 54 aneurysms) and medium aneurysms (18 patients, 23 aneurysms). There were 19 patients with tandem aneurysms (a total of 39 aneurysms) in the two groups, among which 15 patients (30 aneurysms) were in the small aneurysm group and four patients (nine aneurysms) were in the medium aneurysm group. The results show that the mean maximal diameter/neck in the small and medium aneurysms was 3.68/3.25 and 7.61/6.24 mm, respectively. In total, 57 Tubridge flow diverters were successfully implanted without unfolding failure, and there were six patients with new mild cerebral infarction in the small aneurysm group. The complete occlusion rate on the last angiographic follow-up was achieved in 88.46% of the small aneurysms group and 81.82% of the medium aneurysms group. The complete occlusion rate of patients with tandem aneurysms in the last angiographic follow-up was 86.67% (13/15) of the small aneurysms group and 50% (2/4) of the medium aneurysm group. Intracranial hemorrhage was nonencountered in the two groups. ConclusionOur preliminary experience suggests that the Tubridge flow diverter might be a safe and effective treatment for small and medium aneurysms along the internal carotid artery. Long stents may increase the risk of cerebral infarction. Adequate evidence is required to clarify the definite indications and complications in a multicenter randomized controlled trial with a long-term follow-up.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Treatment of Unruptured, Tandem Aneurysms of the ICA with a Single Flow Diverter
    Bhogal, P.
    Chudyk, J.
    Bleise, C.
    Lylyk, I
    Perez, N.
    Henkes, H.
    Lylyk, P.
    CLINICAL NEURORADIOLOGY, 2019, 29 (04) : 725 - 731
  • [32] Angiographic assessment of the efficacy of flow diverter treatment for cerebral aneurysms
    Sadasivan, Chander
    Dholakia, Ronak
    Peeling, Lissa
    Goelitz, Philipp
    Doerfler, Arnd
    Lieber, Baruch B.
    Fiorella, David J.
    Woo, Henry H.
    INTERVENTIONAL NEURORADIOLOGY, 2019, 25 (06) : 655 - 663
  • [33] Endovascular treatment of complex middle cerebral artery aneurysms using TuBridge flow diverters
    Liang, Feng
    Yang, Yibing
    Luo, Lijuan
    Liao, Bingye
    Zhang, Guofeng
    Ou, Siqi
    Xiao, Weiping
    Guo, Ning
    Qi, Tiewei
    INTERVENTIONAL NEURORADIOLOGY, 2020, 26 (05) : 539 - 546
  • [34] Flow diverter stent for treatment of cerebral aneurysms: A report of 130 patients with 134 aneurysms
    Nguyen Thai Binh
    Vu Dang Luu
    Pham Minh Thong
    Nguyen Ngoc Cuong
    Nguyen Quang Anh
    Tran Anh Tuan
    Le Tuan Linh
    Nguyen Tat Thien
    Uddin, Md Jamal
    Thien Chu Dinh
    Dinh-Toi Chu
    HELIYON, 2020, 6 (02)
  • [35] Cerebral Revascularization for Aneurysms in the Flow-Diverter Era
    Straus, David C.
    da Silva, Harley Brito
    McGrath, Lynn
    Levitt, Michael R.
    Kim, Louis J.
    Ghodke, Basavaraj V.
    Barber, Jason K.
    Sekhar, Laligam N.
    NEUROSURGERY, 2017, 80 (05) : 759 - 767
  • [36] The Silk flow-diverter stent for endovascular treatment of intracranial aneurysms
    Alghamdi, Faisal
    Morais, Ricardo
    Scillia, Pietro
    Lubicz, Boris
    EXPERT REVIEW OF MEDICAL DEVICES, 2015, 12 (06) : 753 - 762
  • [37] Effectiveness of Derivo® Flow Diverter Device in the Endovascular Treatment of Cerebrovascular Aneurysms
    Coban, Mustafa Kemal
    Ulku, Goktug
    Sahin, Mustafa Caglar
    Unal, Cansu
    Okay, Hilmi Onder
    TURKISH NEUROSURGERY, 2023, 33 (04) : 591 - 595
  • [38] Stent and flow diverter assisted treatment of acutely ruptured brain aneurysms
    Cohen, Jose E.
    Gomori, J. Moshe
    Leker, Ronen R.
    Spektor, Sergey
    Abu El Hassan, Hosni
    Itshayek, Eyal
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2018, 10 (09) : 851 - 858
  • [39] Analysis of the safety and efficacy of flow diverter device in the treatment of tandem aneurysms in the internal carotid artery
    Wan, Jun
    Xu, Ligang
    Jiang, Yeqing
    Zhang, Lei
    Wang, Zhenyu
    Zhang, Xiaolong
    Wang, Shengzhang
    FRONTIERS IN NEUROLOGY, 2025, 16
  • [40] Late recurrence of a completely occluded large intracranial aneurysm treated with a Tubridge flow diverter
    Zhang, Xiaoxi
    Lv, Nan
    Wang, Chi
    Cao, Wei
    Liu, Jianmin
    Huang, Qinghai
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (02) : E6 - U8