Insertion and removal torque of dental implants placed using different drilling protocols: An experimental study on artificial bone substitutes

被引:4
作者
Romeo, Davide [1 ,2 ]
Chochlidakis, Konstantinos [1 ]
Barmak, Abdul Basir [1 ]
Agliardi, Enrico [2 ]
Lo Russo, Lucio [3 ]
Ercoli, Carlo [1 ]
机构
[1] Univ Rochester, Eastman Inst Oral Hlth, Dept Periodont & Prosthodont, Suite 257,625 Elmwood Ave, Rochester, NY 14620 USA
[2] Univ Vita Salute San Raffaele, San Raffaele Hosp, Dept Dent, Milan, Italy
[3] Univ Foggia, Sch Dent, Dept Clin & Expt Med, Foggia, Italy
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2023年 / 32卷 / 07期
关键词
bone substitutes; cortical bone thickness; implant primary stability; insertion torque; removal torque; surgical technique; PRIMARY STABILITY; OSTEOTOMY PREPARATION; MINERAL DENSITY; THICKNESS; BRANEMARK; 15-YEAR;
D O I
10.1111/jopr.13607
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose The aim of this in vitro study was to measure the insertion and removal torque values of dental implant replicas inserted into artificial bone blocks using different surgical burs and drilling protocols. Materials and methods Four types of artificial, polyurethane bone blocks were used with different thicknesses (1 and 2 mm) and densities (soft-1 mm, soft-2 mm, dense-1 mm, and dense-2 mm) of the simulated cortical and cancellous bone, respectively. Each bone construct was drilled with Straumann and Densah drills in both clockwise and counterclockwise directions for a total of 16 experimental conditions. For every scenario, 38 implant replicas were inserted and then removed after 1 min. Outcomes of interest were the insertion and removal torque values which were recorded by a torque meter. ANOVA and Tukey HSD tests were used to assess differences across each combination of drill, direction, and bone type. Results Densah counterclockwise registered statistically greater values for both insertion and removal torque, followed by Densah clockwise, Straumann counterclockwise, and Straumann clockwise. Increasing insertion and removal torque values were progressively reported for bone type (soft-1 mm, dense-1 mm, soft-2 mm, and dense-2 mm). The mean values of insertion and removal torque were significantly different (p < 0.05) across the four bone types, different burs, and with the two drilling modalities. Conclusions Densah bur resulted in significantly greater values of torque compared to the Straumann drills for all the experimental conditions. The thickness of the cortical layer and the counterclockwise drilling direction play a significant role in determining the implant insertion torque.
引用
收藏
页码:633 / 638
页数:6
相关论文
共 26 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]  
Al-Sabbagh Mohanad, 2019, Dent Clin North Am, V63, P461, DOI 10.1016/j.cden.2019.02.001
[3]  
Barros Luiz-Antonio-Borelli, 2022, J Clin Exp Dent, V14, pe138, DOI 10.4317/jced.58886
[4]  
Chavarri-Prado David, 2020, J Clin Exp Dent, V12, pe242, DOI 10.4317/jced.56014
[5]   Osseodensification outperforms conventional implant subtractive instrumentation: A study in sheep [J].
de Oliveira, Paula G. F. Pessoa ;
Bergamo, Edmara T. P. ;
Neiva, Rodrigo ;
Bonfante, Estevam A. ;
Witek, Lukasz ;
Tovar, Nick ;
Coelho, Paulo G. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2018, 90 :300-307
[6]  
Delgado-Ruiz R., 2020, IADRAADRCADR GEN SES
[7]   Counterclockwise Drilling with Different Tapered Drills Condenses the Implant Bed-An Optical Coherence Tomography In Vitro Study [J].
Delgado-Ruiz, Rafael ;
Mahdian, Mina ;
Benezha, Ilyasse ;
Romanos, Georgios .
MEDICINA-LITHUANIA, 2021, 57 (09)
[8]  
Ercoli C, 2004, INT J ORAL MAX IMPL, V19, P335
[9]  
H Huang, 2020, J Oral Biol Craniofac Res, V10, P629, DOI 10.1016/j.jobcr.2020.07.004
[10]   The Effects of Cortical Bone Thickness and Trabecular Bone Strength on Noninvasive Measures of the Implant Primary Stability Using Synthetic Bone Models [J].
Hsu, Jui-Ting ;
Fuh, Lih-Jyh ;
Tu, Ming-Gene ;
Li, Yu-Fen ;
Chen, Kuan-Ting ;
Huang, Heng-Li .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (02) :251-261