Measurement and Evaluation of Voltage Unbalance in 2 x 25 kV 50 Hz High-Speed Trains Using Variable Integration Period

被引:0
|
作者
Taleb, Yassine [1 ]
Lamrani, Roa [2 ]
Abbou, Ahmed [1 ]
机构
[1] Mohammed V Univ Rabat, Mohammadia Sch Engn, Dept Elect Engn, EREEC Lab, Rabat 11000, Morocco
[2] Ibn Tofail Univ, Natl Sch Appl Sci ENSA, Adv Syst Engn Lab, Kenitra 14000, Morocco
来源
ELECTRICITY | 2024年 / 5卷 / 01期
关键词
railway power supply systems; high-speed trains; power quality meter; EN; 50160; power quality analyzer; voltage unbalance; current unbalance; voltage harmonics; frequency; RAILWAY ELECTRIFICATION;
D O I
10.3390/electricity5010009
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article addresses the need for a standardized method to measure power quality in railroad systems, which differ from distribution and transmission networks. It evaluates the applicability of existing standards in detecting variations and short-term disturbances in railroad networks powered by the 50/60 Hz AC grid or the 2 x 25 kV AC network used for high-speed trains. The objective is to propose a standardized algorithm capable of accurately identifying disturbances to assess power quality on railway traction substations. A new method is proposed to characterize voltage imbalances more precisely. Practical demonstrations confirm that a short integration period, as used in existing standards, provides a more accurate estimation of disturbance amplitude and duration. Field experiments validate the proposed solution, embedded in equipment installed on the 225 kV line supplying the 2 x 25 kV AC substation for high-speed rail. Comparative analysis of results obtained during high-speed train journeys confirms the algorithm's potential to aid standards committees in reviewing and updating existing standards, as well as expediting the creation, approval, and implementation of new standards for railway installations. Experimental comparisons of other power quality parameters, such as frequency and voltage harmonics, also underscore the algorithm's utility in railway power quality assessment.
引用
收藏
页码:154 / 173
页数:20
相关论文
共 4 条
  • [1] A methodology to analyse voltage unbalance mitigation in 2x25 kV-50 Hz railway systems
    Lamedica, R.
    Del Greco, L.
    Ruvio, A.
    Buffarini, G. G.
    Trezza, G.
    2020 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM 2020), 2020, : 600 - 605
  • [2] 2 x 25-kV 50 Hz High-Speed Traction Power System: Short-Circuit Modeling
    Battistelli, Luigi
    Pagano, Mario
    Proto, Daniela
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (03) : 1459 - 1466
  • [3] Impact of High-Voltage Primary Supply Lines in the 2 x 25 kV-50 Hz Railway System on the Equivalent Impedance at Pantograph Terminals
    Dolara, Alberto
    Gualdoni, Moris
    Leva, Sonia
    IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (01) : 164 - 175
  • [4] Sensitivity Analysis of the Constructive Parameters for the 2 x 25-kV High-Speed Railway Lines Planning
    Brenna, Morris
    Foiadelli, Federica
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (03) : 1923 - 1931