Comparison of 3 diagnostic platforms for identification of bacteria and yeast from positive blood culture bottles

被引:4
作者
Smith, Richard D. [1 ,2 ]
Johnson, J. Kristie [1 ]
Ernst, Robert K. [2 ]
机构
[1] Univ Maryland, Sch Med, Dept Pathol, Baltimore, MD 21201 USA
[2] Univ Maryland, Sch Dent, Dept Microbial Pathogenesis, Baltimore, MD 21201 USA
关键词
Blood culture; MALDI-TOF MS; Clinical microbiology; DESORPTION IONIZATION-TIME; FLIGHT MASS-SPECTROMETRY; MALDI-TOF MS; SHORT-TERM INCUBATION; RAPID IDENTIFICATION; STREPTOCOCCUS-PNEUMONIAE; STREAM INFECTIONS; SYSTEM; COST; PERFORMANCE;
D O I
10.1016/j.diagmicrobio.2023.116018
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Managing bloodstream infections requires fast and accurate diagnostics. Culture-based diagnostic methods for identification from positive blood culture require 24-hour subculture, potentially delaying time to appropriate therapy. Positive blood cultures were collected (n = 301) from September 2021 to August 2022 at the University of Maryland Medical Center. Platforms compared were BioFire & REG; BCID2, Sepsityper & REG;, and shortterm culture. For monomicrobial cultures, FilmArray & REG; BCID2 identified 88.3% (241/273) of pathogens. Rapid Sepsityper & REG; identified 76.9% (210/273) of pathogens. Sepsityper & REG; extraction identified 82.4% (225/273) of pathogens. Short-term culture identified 83.5% (228/273) of pathogens. For polymicrobial cultures, Sepsityper & REG;, short-term culture, and BioFire & REG; BCID2 had complete identifications at 10.7% (3/28), 0%, and 92.9% (26/28), respectively. Time-to-results for Rapid Sepsityper & REG;, Sepsityper & REG; extraction, BioFire & REG; BCID2, and Short-term culture were 35, 52, 65, and 306 minutes, respectively. Performance of these platforms can reduce time-to-results and may help effectively treat bloodstream infections faster. Accuracy, time-to-result, and hands-on time are important factors when evaluation diagnostic platforms.& COPY; 2023 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)
引用
收藏
页数:6
相关论文
共 50 条
[21]   An improved protocol for bacteria identification by MALDI-TOF MS directly from positive blood cultures [J].
Cruz, Sara ;
Abreu, David ;
Gomes, Rosario ;
Martins-Oliveira, Ines ;
Silva-Dias, Ana ;
Perez-Viso, Blanca ;
Canton, Rafael ;
Pina-Vaz, Cidalia .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2024, 43 (03) :605-610
[22]   Direct identification of microorganisms in positive blood culture bottles by mass spectrometry (MALDI-TOF MS) [J].
Azula, Natalia ;
Relloso, Silvia ;
Barrios, Ruben ;
Nicola, Federico ;
Smayevsky, Jorgelina .
ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2022, 56 (01) :17-31
[23]   Direct Species Identification in Positive Blood Culture Bottles From Patients With Hematologic Malignancies [J].
Watanabe, Noriyuki ;
Koyama, Sachie ;
Maeda, Tomoya ;
Karaushi, Haruka ;
Taji, Yoshitada ;
Kawasaki, Yohei ;
Takahashi, Naoki ;
Mitsutake, Kotaro ;
Ebihara, Yasuhiro .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
[24]   Rapid identification of bacteria from positive blood culture bottles by MALDI-TOF MS following short-term incubation on solid media [J].
Altun, Osman ;
Botero-Kleiven, Silvia ;
Carlsson, Sarah ;
Ullberg, Mans ;
Ozenci, Volkan .
JOURNAL OF MEDICAL MICROBIOLOGY, 2015, 64 :1346-1352
[25]   Seminested PCR for detection and identification of Candida species directly from blood culture bottles [J].
Cerikcioglu, Nilguen ;
Aksu, Burak ;
Dal, Tuba Demirel ;
Deniz, Umut ;
Bilgen, Huelya Selva ;
Ozek, Eren ;
Soyletir, Guner .
NEW MICROBIOLOGICA, 2010, 33 (01) :57-62
[26]   Multicenter evaluation of the Sepsityper™ extraction kit and MALDI-TOF MS for direct identification of positive blood culture isolates using the BD BACTEC™ FX and VersaTREK® diagnostic blood culture systems [J].
Schieffer, K. M. ;
Tan, K. E. ;
Stamper, P. D. ;
Somogyi, A. ;
Andrea, S. B. ;
Wakefield, T. ;
Romagnoli, M. ;
Chapin, K. C. ;
Wolk, D. M. ;
Carroll, K. C. .
JOURNAL OF APPLIED MICROBIOLOGY, 2014, 116 (04) :934-941
[27]   Comparative evaluation of Vitek 2 identification and susceptibility testing of Gram-negative rods directly and isolated from BacT/ALERT-positive blood culture bottles [J].
Munoz-Davila, M. J. ;
Yaguee, G. ;
Albert, M. ;
Garcia-Lucas, T. .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2012, 31 (05) :663-669
[28]   Identification of micro- organism from positive blood cultures: comparison of three different short culturing methods to the Rapid Sepsityper workflow [J].
Pranada, Arthur B. ;
Cordovana, Miriam ;
Meyer, Markus ;
Hubert, Hilke ;
Abdalla, Mohammad ;
Ambretti, Simone ;
Steinmann, Joerg .
JOURNAL OF MEDICAL MICROBIOLOGY, 2022, 71 (08)
[29]   MALDI-TOF identification of Gram-negative bacteria directly from blood culture bottles containing charcoal: Sepsityper® kits versus centrifugation-filtration method [J].
Riederer, Kathleen ;
Cruz, Kristian ;
Shemes, Stephen ;
Szpunar, Susan ;
Fishbain, Joel T. .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2015, 82 (02) :105-108
[30]   Direct Identification of Bacteria in Positive Blood Culture Bottles by Matrix-Assisted Laser Desorption Ionisation Time-of-Flight Mass Spectrometry [J].
La Scola, Bernard ;
Raoult, Didier .
PLOS ONE, 2009, 4 (11)