Experimental study of simultaneous effect of evacuated tube collectors coupled with parabolic reflectors on traditional single slope solar still efficiency

被引:21
作者
Farghaly, Mohamed B. [1 ,6 ]
Alahmadi, Raed Nayif [2 ]
Sarhan, H. H. [3 ]
Abdelghany, E. S. [4 ,5 ]
机构
[1] Fayoum Univ, Fac Engn, Mech Engn Dept, Al Fayyum 63514, Egypt
[2] Al Baha Univ, Qual & Dev Engn Coll, Al Bahah, Saudi Arabia
[3] Port Said Univ, Fac Engn, Mech Engn Dept, Port Said, Egypt
[4] Al Baha Univ KSA, Fac Engn, Mech Engn Dept, Al Bahah, Egypt
[5] Inst Aviat Engn & Technol, Al Matar, Egypt
[6] Fayoum Univ, Fac Engn, Mech Engn Dept, Keman Faras St, Al Fayyum 63514, Egypt
关键词
Solar desalination; Solar still; Enhancement freshwater productivity; Evacuated tube collectors; Parabolic trough reflector; Efficiency enhancement of solar stills; ENVIRO-ECONOMIC ANALYSIS; WATER DESALINATION; PERFORMANCE; MULTISTAGE; DISTILLER; DESIGNS; AIR;
D O I
10.1016/j.csite.2023.103304
中图分类号
O414.1 [热力学];
学科分类号
摘要
Enhancing the performance characteristics of solar still is considered one of the most significant factors to increase the still efficiency. This research aims to modify the single slope still to enhance efficiency and maximize freshwater productivity. For this purpose, three evacuated tube collectors have been coupled with traditional still to heat up the basin saline water. Also, a parabolic trough reflector has been combined with each evacuated tube collector to increase the amount of solar radiation received. In this work, the performance characteristics and energy analysis of the modified stills were experimentally investigated by considering the effect of traditional still unit only, traditional still unit coupled with an evacuated tube collector, and traditional still unit coupled with both evacuated tube collector and parabolic trough reflectors in combination. The results show that using both modifications simultaneously is more efficient than using each of them separately. According to the results, an increase in productivity of 82.26% when the still coupled with the evacuated tube collectors is used, and 112.57% increase when both modifications are used simultaneously. According to the cost evaluation, using simultaneous mechanisms not only enhances the solar still performance and increase efficiency but also decrease freshwater production cost.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Optimization of condensing tray shapes for a multi-effect solar still coupled with parabolic solar collectors for domestic wastewater treatment: A comparative study
    Ahmad, Akhlaq
    Khan, Zahid Mahmood
    Farid, Hafiz Umar
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2024,
  • [22] Effect of specific height on the performance of a single slope solar still: An experimental study
    Jamil, Basharat
    Akhtar, Naiem
    DESALINATION, 2017, 414 : 73 - 88
  • [23] Experimental study on a single-slope single-basin solar still with air at different velocities
    Prakash, P.
    Velmurugan, V.
    DESALINATION AND WATER TREATMENT, 2017, 85 : 1 - 5
  • [24] Thermal characteristics of evacuated tube solar collectors with coil inside: An experimental study and evolutionary algorithms
    Sadeghi, Gholamabbas
    Najafzadeh, Mohammad
    Ameri, Mehran
    RENEWABLE ENERGY, 2020, 151 : 575 - 588
  • [25] Improving solar still performance with heat pipe/pulsating heat pipe evacuated tube solar collectors and PCM: An experimental and environmental analysis
    Hemmatian, Amir
    Kargarsharifabad, Hadi
    Esfahlani, Ahad Abedini
    Rahbar, Nader
    Shoeibi, Shahin
    SOLAR ENERGY, 2024, 269
  • [26] Experimental study on the effect of coupling parabolic trough collector with double slope solar still on its performance
    Fathy, Mohamed
    Hassan, Hamdy
    Ahmed, M. Salem
    SOLAR ENERGY, 2018, 163 : 54 - 61
  • [27] Experimental study of solar energy–based water purifier of single-slope type by incorporating a number of similar evacuated tubular collectors
    Sanjeev Kumar Sharma
    Ashis Mallick
    Desh Bandhu Singh
    Gopal Nath Tiwari
    Environmental Science and Pollution Research, 2022, 29 : 6837 - 6856
  • [28] Energy metrics and efficiency analyses of double slope solar distiller unit augmented with N identical parabolic concentrator integrated evacuated tubular collectors: a comparative study
    Sharma, Sanjeev Kumar
    Singh, Desh Bandhu
    Mallick, Ashis
    Gupta, Sanjay K.
    DESALINATION AND WATER TREATMENT, 2020, 195 : 40 - 56
  • [29] Thermal Modeling of a Solar Still Coupled with Evacuated Tube Collector under Natural Circulation ModeAn Experimental Validation
    Sampathkumar, K.
    Arjunan, T. V.
    Eswaramoorthy, M.
    Senthilkumar, P.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2013, 35 (15) : 1441 - 1455
  • [30] Experimental study on modified single slope single basin active solar still
    Sandeep
    Kumar, Sudhir
    Dwivedi, V. K.
    DESALINATION, 2015, 367 : 69 - 75