Progress in the reliable detection of near-surface reflectors when inspecting anisotropic and isotropic material using the total focusing method

被引:1
作者
Bergbreiter, L. [1 ,2 ]
Grager, J-C [2 ]
Narr, A. [2 ]
Mooshofer, H. [1 ]
Grosse, C. U. [2 ]
机构
[1] Siemens Technol, D-81739 Munich, Bavaria, Germany
[2] Tech Univ Munich, Chair Nondestruct Testing, D-81245 Munich, Bavaria, Germany
关键词
FULL-MATRIX;
D O I
10.1784/insi.2023.65.5.248
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Load-bearing components made of composite laminates of several centimetres in thickness, for example those used in wind turbine blades, are frequently used in the energy sector. These components are usually tested using conventional ultrasound techniques. A typical approach to increase the energy penetration depth is testing with lower frequencies. This leads to a decrease in sensitivity and consequently to reduced detectability of small defects compared to higher frequencies, especially for defects close to the surface. Another possibility is to use high excitation voltage or gain to improve penetration, but this also leads to a much more pronounced initial pulse with saturated or clipped A-scans, resulting in a loss of information. Consequently, the defects close to the surface are often indistinguishable to the initial pulse and are not detected. In comparison to conventional ultrasonic testing, the total focusing method (TFM) shows higher resolution of near-surface defects using the same frequencies. The TFM can be adapted to anisotropic media by consideration of the direction-dependent wave propagation. Therefore, sound paths not perpendicular to the surface, which show less clipping, can be used for imaging. In this paper, approaches for improving the detectability of defects close to the surface in carbon fibre-reinforced plastic (CFRP) and aluminium using full matrix capture (FMC) and the TFM are discussed. As a result, defects in CFRP with a depth of 0.9 mm and above can be detected. The presented methods also improve the signal-to-noise ratio (SNR) of near-surface defects in the TFM reconstructions up to 4 dB. The first approach filters the FMC pulses in the wavenumber-frequency domain, which reduces the aforementioned disturbances in the time-domain signals and thus improves the detectability of near-surface defects. The second approach is based on a maximum angle in the reconstruction step, which reduces the entries of the information matrix based on location. This procedure is similar to taking the directivity function of each array element into account. Therefore, only time signals with a high signal-to-noise ratio are considered.
引用
收藏
页码:248 / 253
页数:6
相关论文
共 12 条
  • [1] [Anonymous], 2020, The Paris Agreement
  • [2] Stolt's f-k Migration for Plane Wave Ultrasound Imaging
    Garcia, Damien
    Le Tarnec, Louis
    Muth, Stephan
    Montagnon, Emmanuel
    Poree, Jonathan
    Cloutier, Guy
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (09) : 1853 - 1867
  • [3] Grager J C, 2018, P 12 EUR C NONDESTRU
  • [4] Grager J C, 2019, P DACH ANN C FRIEDR
  • [5] Post-processing of the full matrix of ultrasonic transmit-receive array data for non-destructive evaluation
    Holmes, C
    Drinkwater, BW
    Wilcox, PD
    [J]. NDT & E INTERNATIONAL, 2005, 38 (08) : 701 - 711
  • [6] The Wavenumber Algorithm for Full-Matrix Imaging Using an Ultrasonic Array
    Hunter, Alan J.
    Drinkwater, Bruce W.
    Wilcox, Paul D.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (11) : 2450 - 2462
  • [7] Imaging composite material using ultrasonic arrays
    Li, Chuan
    Pain, Damien
    Wilcox, Paul D.
    Drinkwater, Bruce W.
    [J]. NDT & E INTERNATIONAL, 2013, 53 : 8 - 17
  • [8] Materials for Wind Turbine Blades: An Overview
    Mishnaevsky, Leon, Jr.
    Branner, Kim
    Petersen, Helga Norgaard
    Beauson, Justine
    McGugan, Malcolm
    Sorensen, Bent F.
    [J]. MATERIALS, 2017, 10 (11):
  • [9] Narr A, 2018, THESIS TUM GERMANY
  • [10] Rohklin S I, 2011, PHYS ULTRASONICS COM, DOI [10.1093/oso/9780195079609.001.0001, DOI 10.1093/OSO/9780195079609.001.0001]