Deep learning synthesis of cone-beam computed tomography from zero echo time magnetic resonance imaging

被引:8
作者
Choi, Hyeyeon [1 ]
Yun, Jong Pil [2 ]
Lee, Ari [3 ]
Han, Sang-Sun [3 ]
Kim, Sang Woo [1 ]
Lee, Chena [3 ,4 ]
机构
[1] Pohang Univ Sci & Technol, Dept Elect Engn, Pohang 37673, South Korea
[2] Korea Inst Ind Technol, Daegyeong Div, Daegu, South Korea
[3] Yonsei Univ, Dept Oral & Maxillofacial Radiol, Coll Dent, Seoul 03722, South Korea
[4] Yonsei Univ, Inst Innovat Digital Healthcare, Seoul, South Korea
关键词
CT GENERATION;
D O I
10.1038/s41598-023-33288-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Cone-beam computed tomography (CBCT) produces high-resolution of hard tissue even in small voxel size, but the process is associated with radiation exposure and poor soft tissue imaging. Thus, we synthesized a CBCT image from the magnetic resonance imaging (MRI), using deep learning and to assess its clinical accuracy. We collected patients who underwent both CBCT and MRI simultaneously in our institution (Seoul). MRI data were registered with CBCT data, and both data were prepared into 512 slices of axial, sagittal, and coronal sections. A deep learning-based synthesis model was trained and the output data were evaluated by comparing the original and synthetic CBCT (syCBCT). According to expert evaluation, syCBCT images showed better performance in terms of artifacts and noise criteria but had poor resolution compared to the original CBCT images. In syCBCT, hard tissue showed better clarity with significantly different MAE and SSIM. This study result would be a basis for replacing CBCT with non-radiation imaging that would be helpful for patients planning to undergo both MRI and CBCT.
引用
收藏
页数:9
相关论文
共 26 条
[1]   Comparison of different deep learning architectures for synthetic CT generation from MR images [J].
Bahrami, Abbas ;
Karimian, Alireza ;
Arabi, Hossein .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 90 :99-107
[2]   Deep learning methods to generate synthetic CT from MRI in radiotherapy: A literature review [J].
Boulanger, M. ;
Nunes, Jean-Claude ;
Chourak, H. ;
Largent, A. ;
Tahri, S. ;
Acosta, O. ;
De Crevoisier, R. ;
Lafond, C. ;
Barateau, A. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 89 :265-281
[3]  
Chen H.-M., 2004, Advanced Image Processing Techniques for Remotely Sensed Hyperspectral Data, P89, DOI 10.1007/978-3-662-05605-9_4
[4]   Synthetic CT generation from CBCT images via unsupervised deep learning [J].
Chen, Liyuan ;
Liang, Xiao ;
Shen, Chenyang ;
Nguyen, Dan ;
Jiang, Steve ;
Wang, Jing .
PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (11)
[5]  
Gholamiankhah F, 2021, Arxiv, DOI [arXiv:2103.01609, 10.48550/arXiv.2103.01609]
[6]   MR-based synthetic CT generation using a deep convolutional neural network method [J].
Han, Xiao .
MEDICAL PHYSICS, 2017, 44 (04) :1408-1419
[7]   Deep Residual Learning for Image Recognition [J].
He, Kaiming ;
Zhang, Xiangyu ;
Ren, Shaoqing ;
Sun, Jian .
2016 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2016, :770-778
[8]   High-Resolution Single Tooth MRI With an Inductively Coupled Intraoral Coil-Can MRI Compete With CBCT? [J].
Hilgenfeld, Tim ;
Saleem, Muhammad Abdullah ;
Schwindling, Franz Sebastian ;
Ludwig, Ute ;
Hoevener, Jan-Bernd ;
Bock, Michael ;
Fluegge, Tabea ;
Eisenbeiss, Anne-Katrin ;
Nittka, Mathias ;
Mente, Johannes ;
Jende, Johann Malte Enno ;
Heiland, Sabine ;
Bendszus, Martin ;
Juerchott, Alexander .
INVESTIGATIVE RADIOLOGY, 2022, 57 (11) :720-727
[9]   Use of dental MRI for radiation-free guided dental implant planning: a prospective, in vivo study of accuracy and reliability [J].
Hilgenfeld, Tim ;
Juerchott, Alexander ;
Jende, Johann M. E. ;
Rammelsberg, Peter ;
Heiland, Sabine ;
Bendszus, Martin ;
Schwindling, Franz S. .
EUROPEAN RADIOLOGY, 2020, 30 (12) :6392-6401
[10]   Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT) [J].
Jin, Jian-Yue ;
Ren, Lei ;
Liu, Qiang ;
Kim, Jinkoo ;
Wen, Ning ;
Guan, Huaiqun ;
Movsas, Benjamin ;
Chetty, Indrin J. .