Iron Determination in Natural Waters Using a Synthesised 3-Hydroxy-4-Pyridione Ligand in a Newly Developed Microfluidic Paper-Based Device

被引:5
|
作者
Aguiar, Juliana I. S. [1 ]
Ribeiro, Susana O. [2 ]
Leite, Andreia [2 ]
Rangel, Maria [3 ]
Rangel, Antonio O. S. S. [1 ]
Mesquita, Raquel B. R. [1 ]
机构
[1] Univ Catolica Portuguesa, CBQF Ctr Biotecnol & Quim Fina, Lab Associado, Escola Super Biotecnol, P-4169005 Porto, Portugal
[2] Univ Porto, Fac Ciencias, Dept Quim & Bioquim, REQUIMTE LAQV, P-4169007 Porto, Portugal
[3] Univ Porto, REQUIMTE LAQV, Inst Ciencias Biomed Abel Salazar, P-4050313 Porto, Portugal
关键词
iron quantification sensor; microfluidic paper-based analytical device; 3-hydroxy-4-pyridinone ligand; natural waters; in situ analysis; INJECTION-ANALYSIS; SPECIATION; COPPER;
D O I
10.3390/chemosensors11020101
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work describes the development of an iron sensor based on a microfluidic paper-based technique, to attain iron quantification in natural waters. A new water-soluble naphthalene-3-hydroxy-4-pyridione ligand was used as a colour reagent, as it formed an orange complex with iron. As a newly described ligand, several chemical and physical parameters, namely, the sample and reagent volumes and reagent concentrations, were studied related to the formation of the coloured complex. The microfluidic paper-based analytical device (mu PAD) assembly, namely, the use of different types of filter paper and different numbers of layers, was developed to obtain the best performance. Under the optimal conditions, a linear correlation was obtained in the range of 0.25-2.00 mg/L of iron, with a minimum detectable value of 0.07 mg/L. The proposed mu PAD method was validated by an analysis of the certified samples and by a comparison of the tested water samples with the inductively coupled plasma (ICP) results (RE < 10%). Then, the mu PAD device was successfully applied to the determination of iron in tap water, well water, river water, and seawater, with no need for any prior sample pre-treatment; recovery studies were also performed (average = 100.3% with RSD = 4.2%).
引用
收藏
页数:13
相关论文
共 13 条
  • [1] Use of an ether-derived 3-hydroxy-4-pyridinone chelator as a new chromogenic reagent in the development of a microfluidic paper-based analytical device for Fe(III) determination in natural waters
    Moniz, Tania
    Bassett, Chelsea R.
    Almeida, M. Ines G. S.
    Kolev, Spas D.
    Rangel, Maria
    Mesquita, Raquel B. R.
    TALANTA, 2020, 214
  • [2] Determination of Iron Ion in the Water of a Natural Hot Spring Using Microfluidic Paper-based Analytical Devices
    Kazuma Ogawa
    Takashi Kaneta
    Analytical Sciences, 2016, 32 : 31 - 34
  • [3] Determination of Iron Ion in the Water of a Natural Hot Spring Using Microfluidic Paper-based Analytical Devices
    Ogawa, Kazuma
    Kaneta, Takashi
    ANALYTICAL SCIENCES, 2016, 32 (01) : 31 - 34
  • [4] Targeting iron speciation in wines: Design of a microfluidic paper-based device for determination of iron(II) and iron(III)
    Mesquita, Raquel B. R.
    Klima, Christina
    Martinez-Perez-Cejuela, H.
    Monforte, Ana R.
    Ferreira, A. C. Silva
    Rangel, Antonio O. S. S.
    MICROCHEMICAL JOURNAL, 2023, 188
  • [5] Use of a rhodamine-based chelator in a microfluidic paper-based analytical device for the in-situ copper quantification in natural waters
    Aguiar, Juliana I. S.
    Ribeiro, Susana O.
    Leite, Andreia
    Rangel, Maria
    Rangel, Antonio O. S. S.
    Mesquita, Raquel B. R.
    TALANTA, 2024, 271
  • [6] Microfluidic paper-based analytical device for determination of sucrose in sugarcane juice using Benedict’s reagent
    Nuanlaor Ratanawimarnwong
    Vanlada Suksomphot
    Khemika Sornpipatpong
    Supamit Lengwan
    Suchao Donpudsa
    Nuthawut Choengchan
    Thitirat Mantim
    Analytical and Bioanalytical Chemistry, 2022, 414 : 7783 - 7791
  • [7] Sensitive Determination of Hexavalent Chromium Using a Microfluidic Paper-based Analytical Device with Solid Phase Extraction
    Asano, Hitoshi
    Maeda, Taishiro
    Shiraishi, Yukihide
    BUNSEKI KAGAKU, 2021, 70 (06) : 379 - 383
  • [8] Microfluidic paper-based analytical device for determination of sucrose in sugarcane juice using Benedict's reagent
    Ratanawimarnwong, Nuanlaor
    Suksomphot, Vanlada
    Sornpipatpong, Khemika
    Lengwan, Supamit
    Donpudsa, Suchao
    Choengchan, Nuthawut
    Mantim, Thitirat
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (27) : 7783 - 7791
  • [9] Determination of phosphorus in water and chemical fertilizer samples using a simple drawing microfluidic paper-based analytical device
    Piyawan Phansi
    Sirinthip Janthama
    Víctor Cerdà
    Duangjai Nacapricha
    Analytical Sciences, 2022, 38 : 1323 - 1332
  • [10] Determination of phosphorus in water and chemical fertilizer samples using a simple drawing microfluidic paper-based analytical device
    Phansi, Piyawan
    Janthama, Sirinthip
    Cerda, Victor
    Nacapricha, Duangjai
    ANALYTICAL SCIENCES, 2022, 38 (10) : 1323 - 1332