Comparison of heat-transfer performance of a flat-plate pulsating heat pipe based on heating orientation and cross- sectional shape of the pipe

被引:2
|
作者
Yasuda, Yosuke [1 ]
Nabeshima, Fumika [2 ]
Horiuchi, Keisuke [1 ]
Nagai, Hiroki [1 ]
机构
[1] Hitachi Ltd, Res & Dev Grp, 832-2 Horiguchi, Hitachinaka, Ibaraki 3120034, Japan
[2] Tohoku Univ, Inst Fluid Sci, 2-1-1 Katahira, Aoba Ku, Sendai, Miyagi 9808577, Japan
来源
MECHANICAL ENGINEERING JOURNAL | 2023年 / 10卷 / 02期
关键词
Pulsating heat pipe; Oscillating heat pipe; HFO; R1336mzz(Z); Closed-end; Flat-plate; CLOSED-LOOP; FLOW VISUALIZATION; LIMIT; PART;
D O I
10.1299/mej.22-00415
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The effects of cross-sectional shapes of flat-plate pulsating heat pipes (PHPs) on heat-transfer performance were experimentally investigated. The flat-plate PHP, made of aluminum alloy, has a closed-end serpentine channel with 22 turns. Four PHP samples with different channel shape (square or circular), the hydraulic diameter of the channel (1 or 1.2 mm), and plate thickness (3 or 2 mm) were prepared. The working fluid in the channel is R1336mzz(Z), and its filling ratio was increased from 30 mass% to 70 mass% in increments of 10 mass%. The heating section of the PHP is heated at power from 20 to 180 W in one of three heating orientations (vertical bottom, top, and horizontal) and the cooling section of the PHP is kept at 40 degrees C. Equivalent thermal conductivity is calculated from temperature on the surface of the PHP and heat transport rate. The experimental results indicate that the larger the cross-sectional area of the channel-wall material, the more likely it is that working-fluid oscillation will occur in the case of the top and horizontal heating orientations. Within the scope of this study, The PHP sample with a 1.2x1.2-mm square channel, the thickness of 3 mm, and filling ratio of 40 mass% has the highest equivalent thermal conductivity, namely, 2880 W/(m center dot K) at heat-transport rate Q of 146 W in top -heating orientation, 2750 W/(m center dot K) at Q = 146 W in horizontal-heating orientation, and 6540 W/(m center dot K) at Q = 36 W in bottom-heating orientation. As for that PHP, when Q is 80 W or more, equivalent thermal conductivities are the same regardless of heating orientation. It is thus considered that under that condition, working-fluid behaviors of the PHP become equivalent regardless of the heating orientation.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 50 条
  • [11] Thermographic Investigation on Fluid Oscillations and Transverse Interactions in a Fully Metallic Flat-Plate Pulsating Heat Pipe
    Pagliarini, Luca
    Cattani, Luca
    Ayel, Vincent
    Slobodeniuk, Maksym
    Romestant, Cyril
    Bozzoli, Fabio
    APPLIED SCIENCES-BASEL, 2023, 13 (10):
  • [12] Effect of a channel layout on the thermal performance of a flat plate micro pulsating heat pipe under the local heating condition
    Lim, Jonghyun
    Kim, Sung Jin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 137 : 1232 - 1240
  • [13] An experimental investigation on heat transfer performance of pulsating heat pipe
    Fumin Shang
    Shilong Fan
    Qingjing Yang
    Jianhong Liu
    Journal of Mechanical Science and Technology, 2020, 34 : 425 - 433
  • [14] Influences of inclination angle and heating power on heat transfer performance of ethane pulsating heat pipe
    Chen X.
    Lin Y.
    Shao S.
    Huagong Xuebao/CIESC Journal, 2019, 70 (04): : 1383 - 1389
  • [15] Investigation of a flat-plate oscillating heat pipe with Tesla-type check valves
    Thompson, S. M.
    Ma, H. B.
    Wilson, C.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2011, 35 (07) : 1265 - 1273
  • [16] Experimental study on heat transfer performance using a hybrid cooling method combined of a flat-plate heat pipe and spray cooling
    Ni, Qin
    Ling, Xiang
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 46
  • [17] Novel flat plate pulsating heat pipe with ultra sharp grooves
    Krambeck, Larissa
    Domiciano, Kelvin G.
    Betancur-Arboleda, Luis A.
    Mantelli, Marcia B. H.
    APPLIED THERMAL ENGINEERING, 2022, 211
  • [18] Experimental Study on Heat Transfer Performance of Pulsating Heat Pipe with Refrigerants
    Wang Xingyu
    Jia Li
    JOURNAL OF THERMAL SCIENCE, 2016, 25 (05) : 449 - 453
  • [19] An Experimental Investigation on Heat Transfer Performance of Nanofluid Pulsating Heat Pipe
    Hongwei Jia
    Li Jia
    Zetao Tan
    Journal of Thermal Science, 2013, 22 (05) : 484 - 490
  • [20] Experimental Study on Heat Transfer Performance of Pulsating Heat Pipe with Refrigerants