Optical design and fabrication of zinc selenide microlens array with extended depth of focus for biomedical imaging

被引:4
|
作者
Khatri, Neha [1 ,2 ]
Berwal, Sonam [1 ,2 ]
Manjunath, K. [1 ,2 ]
Singh, Bharpoor [1 ]
机构
[1] CSIR Cent Sci Instruments Org, Chandigarh 160030, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
来源
NANOFABRICATION | 2023年 / 8卷
关键词
optical coherence tomography; microlens array; zinc selenide; slow tool servo; optical design; COHERENCE TOMOGRAPHY; TOOL SERVO; LENS ARRAY; SURFACE;
D O I
10.37819/nanofab.008.293
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Optical coherence tomography is a well-known technique for the optical imaging of biological tissues. However, the depth scanning range of high-resolution optical coherence tomography is restricted by its depth of focus. In this study, a come the depth-of-focus limitation of optical coherence tomography. The ZnSe material with a low Abbe number and high chromatic dispersion extends the depth of focus with transverse resolution. The ZnSe MLA focused the incident light (from visible to near-infrared (NIR) region) on multiple focal planes with the uniform distribution of light over a biological tissue. The MLA is designed using Zemax OpticStudio software and fabricated via a single-point diamond-turning based on Slow Tool Servo (STS) configuration. STS machining has the unique advantage of offering larger degrees of freedom with no additional baggage, thereby reducing the setup time. The experimental results show the effectiveness of the STS machining process in fabricating ZnSe MLA with desired accuracies. The characterization of fabdepicts uniform lenslets with no structural and positional distortion, with a total error of 32 nm within the tolerance limit.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [41] Single-step fabrication of a microlens array in sol-gel material by direct laser writing and its application in optical coupling
    He, M
    Yuan, XC
    Ngo, NQ
    Tao, SH
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2004, 6 (01): : 94 - 97
  • [42] Design and fabrication of a coherent array of single-mode optical fibers for the nulling coronagraph
    Liu, DT
    Levine, BM
    Shao, M
    TECHNIQUES AND INSTRUMENTATION FOR DETECTION OF EXOPLANETS, 2003, 5170 : 217 - 228
  • [43] The prime focus imaging spectrograph for the Southern African large telescope: optical design
    Burgh, EB
    Nokdsieck, KH
    Kobulnicky, HA
    Williams, TB
    O'Donoghue, D
    Smith, MP
    Percival, JW
    INSTRUMENT DESIGN AND PERFORMANCE FOR OPTICAL/INFRARED GROUND-BASED TELESCOPES, PTS 1-3, 2003, 4841 : 1463 - 1471
  • [44] Laser imaging optical system design with a shared aperture employing APD array
    Yu Xiao
    Yao Yuan
    Xu Zheng-ping
    CHINESE OPTICS, 2016, 9 (03): : 349 - 355
  • [45] Multifocal spectral-domain optical coherence tomography based on Bessel beam for extended imaging depth
    Yi, Luying
    Sun, Liqun
    Ding, Wuwen
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (10)
  • [46] Analysis of Design and Fabrication Parameters for Lensed Optical Fibers as Pertinent Probes for Sensing and Imaging
    Park, Soongho
    Rim, Sunghwan
    Kim, Ju Wan
    Park, Jinho
    Sohn, Ik-Bu
    Lee, Byeong Ha
    SENSORS, 2018, 18 (12)
  • [47] Design of optical imaging system for full-ocean-depth low-light colors
    Yang Jiang
    Quan, Xiang-qian
    Yan Xing
    Li Da-yong
    Zheng Xiong
    Qiang Sun
    OPTICS AND LASERS IN ENGINEERING, 2022, 154
  • [48] Design of optical imaging system for full-ocean-depth low-light colors
    Yang Jiang
    Quan, Xiang-qian
    Yan Xing
    Li Da-yong
    Zheng Xiong
    Qiang Sun
    OPTICS AND LASERS IN ENGINEERING, 2022, 154
  • [49] 3D-printed micro-axicon enables extended depth-of-focus intravascular optical coherence tomography in vivo
    Ruchka, Pavel
    Kushwaha, Alok
    Marathe, Jessica A.
    Xiang, Lei
    Chen, Rouyan
    Kirk, Rodney
    Tan, Joanne T. M.
    Bursill, Christina A.
    Verjans, Johan
    Thiele, Simon
    Fitridge, Robert
    Mclaughlin, Robert A.
    Psaltis, Peter J.
    Giessen, Harald
    Li, Jiawen
    ADVANCED PHOTONICS, 2025, 7 (02):
  • [50] All-fiber probe for optical coherence tomography with an extended depth of focus by a high-efficient fiber-based filter
    Qiu, Jianrong
    Shen, Yi
    Shangguan, Ziwei
    Bao, Wen
    Yang, Shanshan
    Li, Peng
    Ding, Zhihua
    OPTICS COMMUNICATIONS, 2018, 413 : 276 - 282