Impact of MRI resolution for Linac-based stereotactic radiosurgery

被引:0
|
作者
Huang, Yimei [1 ]
Liang, Evan [1 ]
Schaff, Eric M. [1 ]
Zhao, Bo [1 ]
Snyder, Karen C. [1 ]
Chetty, Indrin J. [1 ]
Shah, Mira M. [1 ]
Siddiqui, Salim M. [1 ]
机构
[1] Henry Ford Hlth, Dept Radiat Oncol, Detroit, MI 48202 USA
来源
FRONTIERS IN ONCOLOGY | 2023年 / 13卷
关键词
MRI resolution; partial volume; radiosurgery; target definition; plan quality; GAMMA-KNIFE SURGERY; BRAIN METASTASES; RADIATION-THERAPY;
D O I
10.3389/fonc.2023.1090582
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: Magnetic resonance imaging (MRI) is a standard imaging modality in intracranial stereotactic radiosurgery (SRS) for defining target volumes. However, wide disparities in MRI resolution exist, which could directly impact accuracy of target delineation. Here, sequences with various MRI resolution were acquired on phantoms to evaluate the effect on volume definition and dosimetric consequence for cranial SRS.Materials/Methods: Four T1-weighted MR sequences with increasing 3D resolution were compared, including two Spin Echo (SE) 2D acquisitions with 5mm and 3mm slice thickness (SE5mm, SE3mm) and two gradient echo 3D acquisitions (TFE, BRAVO). The voxel sizes were 0.4x0.4x5.0, 0.5x0.5x3.0, 0.9x0.9x1.25, and 0.4x0.4x0.5 mm(3), respectively. Four phantoms with simulated lesions of different shape and volume (range, 0.53-25.0 cm(3)) were imaged, resulting in 16 total sets of MRIs. Four radiation oncologists provided contours on individual MR image set. All observer contours were compared with ground truth, defined on CT image according to the absolute dimensions of the target structure, using Dice similarity coefficient (DSC), Hausdorff distance (HD), mean distance-to-agreement (MDA), and the ratio between reconstructed and true volume (Ratio(vol)). For dosimetric consequence, SRS plans targeting observer volumes were created. The true Paddick conformity index (CIpaddicktrue ), calculated with true target volume, was correlated with quality of observer volume.Results: All measures of observer contours improved as increasingly higher MRI resolution was provided from SE5mm to BRAVO. The improvement in DSC, HD and MDA was statistically significant (p < 0.01). Dosimetrically, CIpaddicktrue strongly correlated with DSC of the planning observer volume (Pearson's r=0.94, p < 0.00001).Conclusions: Significant improvement in target definition and reduced inter observer variation was observed as the MRI resolution improved, which also improved the quality of SRS plans. Results imply that high resolution 3D MR sequences should be used to minimize potential errors in target definition, and multi-slice 2D sequences should be avoided.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Dosimetric comparison of robotic- and LINAC-based treatment of spine stereotactic body radiotherapy
    Acar, Hilal
    Yazici, Omer
    Unal, Dilek
    MEDICAL DOSIMETRY, 2022, 47 (04) : 348 - 355
  • [42] LINAC-based stereotactic radiosurgery versus hypofractionated stereotactic radiotherapy delivered in 3 or 5 fractions for vestibular schwannomas: comparative assessment from a single institution
    Soderlund Diaz, Linn
    Hallqvist, Andreas
    JOURNAL OF NEURO-ONCOLOGY, 2020, 147 (02) : 351 - 359
  • [43] Intrafraction variations in linac-based image-guided radiosurgery of intracranial lesions
    Badakhshi, H.
    Barelkowski, T.
    Wust, P.
    Budach, V.
    Boehmer, D.
    Graf, R.
    CANCER RADIOTHERAPIE, 2013, 17 (07): : 664 - 667
  • [44] To frame or not to frame? Cone-beam CT-based analysis of head immobilization devices specific to linac-based stereotactic radiosurgery and radiotherapy
    Babic, Steven
    Lee, Young
    Ruschin, Mark
    Lochray, Fiona
    Lightstone, Alex
    Atenafu, Eshetu
    Phan, Nic
    Mainprize, Todd
    Tsao, May
    Soliman, Hany
    Sahgal, Arjun
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 111 - 120
  • [45] Transient enlargement of contrast uptake on MRI after linear accelerator (linac) stereotactic radiosurgery for brain metastases
    Huber, PE
    Hawighorst, H
    Fuss, M
    van Kaick, G
    Wannenmacher, MF
    Debus, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (05): : 1339 - 1349
  • [46] Outcomes and the Role of Primary Histology Following LINAC-based Stereotactic Radiation for Sarcoma Brain Metastases
    Sim, Austin J.
    Ahmed, Kamran A.
    Keller, Andrew
    Figura, Nicholas B.
    Oliver, Daniel E.
    Sarangkasiri, Siriporn
    Robinson, Timothy J.
    Johnstone, Peter A. S.
    Yu, Hsiang-Hsuan Michael
    Naghavi, Arash O.
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2020, 43 (05): : 356 - 361
  • [47] DIFFERENCES IN CLINICAL RESULTS AFTER LINAC-BASED SINGLE-DOSE RADIOSURGERY VERSUS FRACTIONATED STEREOTACTIC RADIOTHERAPY FOR PATIENTS WITH VESTIBULAR SCHWANNOMAS
    Combs, Stephanie E.
    Welzel, Thomas
    Schulz-Ertner, Daniela
    Huber, Peter E.
    Debus, Juergen
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (01): : 193 - 200
  • [48] Frameless linac-based stereotactic radiosurgery (SRS) for brain metastases: analysis of patient repositioning using a mask fixation system and clinical outcomes
    Giuseppe Minniti
    Claudia Scaringi
    Enrico Clarke
    Maurizio Valeriani
    Mattia Osti
    Riccardo Maurizi Enrici
    Radiation Oncology, 6
  • [49] Failure mode and effects analysis of linac-based liver stereotactic body radiotherapy
    Rusu, Iris
    Thomas, Tarita O.
    Roeske, John C.
    Mescioglu, Ibrahim
    Melian, Edward
    Surucu, Murat
    MEDICAL PHYSICS, 2020, 47 (03) : 937 - 947
  • [50] Optically-guided frameless linac-based radiosurgery for brain metastases: clinical experience
    Sameer K. Nath
    Joshua D. Lawson
    Jia-Zhu Wang
    Daniel R. Simpson
    C. Benjamin Newman
    John F. Alksne
    Arno J. Mundt
    Kevin T. Murphy
    Journal of Neuro-Oncology, 2010, 97 : 67 - 72