Impact of MRI resolution for Linac-based stereotactic radiosurgery

被引:0
|
作者
Huang, Yimei [1 ]
Liang, Evan [1 ]
Schaff, Eric M. [1 ]
Zhao, Bo [1 ]
Snyder, Karen C. [1 ]
Chetty, Indrin J. [1 ]
Shah, Mira M. [1 ]
Siddiqui, Salim M. [1 ]
机构
[1] Henry Ford Hlth, Dept Radiat Oncol, Detroit, MI 48202 USA
来源
FRONTIERS IN ONCOLOGY | 2023年 / 13卷
关键词
MRI resolution; partial volume; radiosurgery; target definition; plan quality; GAMMA-KNIFE SURGERY; BRAIN METASTASES; RADIATION-THERAPY;
D O I
10.3389/fonc.2023.1090582
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: Magnetic resonance imaging (MRI) is a standard imaging modality in intracranial stereotactic radiosurgery (SRS) for defining target volumes. However, wide disparities in MRI resolution exist, which could directly impact accuracy of target delineation. Here, sequences with various MRI resolution were acquired on phantoms to evaluate the effect on volume definition and dosimetric consequence for cranial SRS.Materials/Methods: Four T1-weighted MR sequences with increasing 3D resolution were compared, including two Spin Echo (SE) 2D acquisitions with 5mm and 3mm slice thickness (SE5mm, SE3mm) and two gradient echo 3D acquisitions (TFE, BRAVO). The voxel sizes were 0.4x0.4x5.0, 0.5x0.5x3.0, 0.9x0.9x1.25, and 0.4x0.4x0.5 mm(3), respectively. Four phantoms with simulated lesions of different shape and volume (range, 0.53-25.0 cm(3)) were imaged, resulting in 16 total sets of MRIs. Four radiation oncologists provided contours on individual MR image set. All observer contours were compared with ground truth, defined on CT image according to the absolute dimensions of the target structure, using Dice similarity coefficient (DSC), Hausdorff distance (HD), mean distance-to-agreement (MDA), and the ratio between reconstructed and true volume (Ratio(vol)). For dosimetric consequence, SRS plans targeting observer volumes were created. The true Paddick conformity index (CIpaddicktrue ), calculated with true target volume, was correlated with quality of observer volume.Results: All measures of observer contours improved as increasingly higher MRI resolution was provided from SE5mm to BRAVO. The improvement in DSC, HD and MDA was statistically significant (p < 0.01). Dosimetrically, CIpaddicktrue strongly correlated with DSC of the planning observer volume (Pearson's r=0.94, p < 0.00001).Conclusions: Significant improvement in target definition and reduced inter observer variation was observed as the MRI resolution improved, which also improved the quality of SRS plans. Results imply that high resolution 3D MR sequences should be used to minimize potential errors in target definition, and multi-slice 2D sequences should be avoided.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] ASSURANCE OF HIGH-QUALITY LINAC-BASED STEREOTAXIC RADIOSURGERY
    DRZYMALA, RE
    KLEIN, EE
    SIMPSON, JR
    RICH, KM
    WASSERMAN, TH
    PURDY, JA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (02): : 459 - 472
  • [32] The effect of setup uncertainty on optimal dosimetric margin in LINAC-based stereotactic radiosurgery with dynamic conformal arc technique
    Duan, Xiaoyu
    Giles, William
    Kirkpatrick, John P.
    Yin, Fang-Fang
    JOURNAL OF RADIOSURGERY AND SBRT, 2019, 6 (01): : 55 - 65
  • [33] LINAC-based radiosurgery for melanoma, sarcoma and renal cell carcinoma brain metastases
    Maranzano, Ernesto
    Casale, Michelin
    Rispoli, Rossella
    Trippa, Fabio
    Draghini, Lorena
    Arcidiacono, Fabio
    Carletti, Sandro
    Anselmo, Paola
    JOURNAL OF NEUROSURGICAL SCIENCES, 2020, 64 (01) : 37 - 43
  • [34] Single-Isocenter Linac-Based Radiosurgery for Brain Metastases with Coplanar Arcs: A Dosimetric and Clinical Analysis
    Faccenda, Valeria
    Panizza, Denis
    Pisoni, Valerio
    Trivellato, Sara
    Daniotti, Martina Camilla
    Bianchi, Sofia Paola
    De Ponti, Elena
    Arcangeli, Stefano
    CANCERS, 2023, 15 (18)
  • [35] Frameless linac-based stereotactic radiosurgery (SRS) for brain metastases: analysis of patient repositioning using a mask fixation system and clinical outcomes
    Minniti, Giuseppe
    Scaringi, Claudia
    Clarke, Enrico
    Valeriani, Maurizio
    Osti, Mattia
    Enrici, Riccardo Maurizi
    RADIATION ONCOLOGY, 2011, 6
  • [36] Treatment of brain metastases in patients with non-small cell lung cancer (NSCLC) by stereotactic linac-based radiosurgery: prognostic factors
    Zabel, A
    Milker-Zabel, S
    Thilmann, C
    Zuna, I
    Rhein, B
    Wannenmacher, M
    Debus, J
    LUNG CANCER, 2002, 37 (01) : 87 - 94
  • [37] Stereotactic LINAC radiosurgery for the treatment of brainstem cavernomas
    Fuetsch, M.
    El Majdoub, F.
    Hoevels, M.
    Mueller, R. P.
    Sturm, V.
    Maarouf, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (04) : 311 - 316
  • [38] Optically-guided frameless linac-based radiosurgery for brain metastases: clinical experience
    Nath, Sameer K.
    Lawson, Joshua D.
    Wang, Jia-Zhu
    Simpson, Daniel R.
    Newman, C. Benjamin
    Alksne, John F.
    Mundt, Arno J.
    Murphy, Kevin T.
    JOURNAL OF NEURO-ONCOLOGY, 2010, 97 (01) : 67 - 72
  • [39] Twelve-year results of LINAC-based radiosurgery for vestibular schwannomas
    Anselmo, Paola
    Casale, Michelina
    Arcidiacono, Fabio
    Trippa, Fabio
    Rispoli, Rossella
    Draghini, Lorena
    Terenzi, Sara
    Di Marzo, Alessandro
    Maranzano, Ernesto
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (01) : 40 - 47
  • [40] Effects of irradiation geometry on treatment plan optimization with linac-based radiosurgery
    Phillips, MH
    Stelzer, KJ
    Mayberg, MR
    Winn, HR
    MEDICAL PHYSICS, 1996, 23 (08) : 1399 - 1406