Impact of MRI resolution for Linac-based stereotactic radiosurgery

被引:0
|
作者
Huang, Yimei [1 ]
Liang, Evan [1 ]
Schaff, Eric M. [1 ]
Zhao, Bo [1 ]
Snyder, Karen C. [1 ]
Chetty, Indrin J. [1 ]
Shah, Mira M. [1 ]
Siddiqui, Salim M. [1 ]
机构
[1] Henry Ford Hlth, Dept Radiat Oncol, Detroit, MI 48202 USA
来源
FRONTIERS IN ONCOLOGY | 2023年 / 13卷
关键词
MRI resolution; partial volume; radiosurgery; target definition; plan quality; GAMMA-KNIFE SURGERY; BRAIN METASTASES; RADIATION-THERAPY;
D O I
10.3389/fonc.2023.1090582
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: Magnetic resonance imaging (MRI) is a standard imaging modality in intracranial stereotactic radiosurgery (SRS) for defining target volumes. However, wide disparities in MRI resolution exist, which could directly impact accuracy of target delineation. Here, sequences with various MRI resolution were acquired on phantoms to evaluate the effect on volume definition and dosimetric consequence for cranial SRS.Materials/Methods: Four T1-weighted MR sequences with increasing 3D resolution were compared, including two Spin Echo (SE) 2D acquisitions with 5mm and 3mm slice thickness (SE5mm, SE3mm) and two gradient echo 3D acquisitions (TFE, BRAVO). The voxel sizes were 0.4x0.4x5.0, 0.5x0.5x3.0, 0.9x0.9x1.25, and 0.4x0.4x0.5 mm(3), respectively. Four phantoms with simulated lesions of different shape and volume (range, 0.53-25.0 cm(3)) were imaged, resulting in 16 total sets of MRIs. Four radiation oncologists provided contours on individual MR image set. All observer contours were compared with ground truth, defined on CT image according to the absolute dimensions of the target structure, using Dice similarity coefficient (DSC), Hausdorff distance (HD), mean distance-to-agreement (MDA), and the ratio between reconstructed and true volume (Ratio(vol)). For dosimetric consequence, SRS plans targeting observer volumes were created. The true Paddick conformity index (CIpaddicktrue ), calculated with true target volume, was correlated with quality of observer volume.Results: All measures of observer contours improved as increasingly higher MRI resolution was provided from SE5mm to BRAVO. The improvement in DSC, HD and MDA was statistically significant (p < 0.01). Dosimetrically, CIpaddicktrue strongly correlated with DSC of the planning observer volume (Pearson's r=0.94, p < 0.00001).Conclusions: Significant improvement in target definition and reduced inter observer variation was observed as the MRI resolution improved, which also improved the quality of SRS plans. Results imply that high resolution 3D MR sequences should be used to minimize potential errors in target definition, and multi-slice 2D sequences should be avoided.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Linac-based hypofractionated stereotactic radiotherapy for metastases involving the brainstem
    Ortiz, Michael
    Herbert, Joseph
    Hika, Busha
    Biedermann, Gregory
    Phillips, Leslie
    Wexler, Amelia
    Litofsky, N. Scott
    JOURNAL OF CLINICAL NEUROSCIENCE, 2022, 98 : 235 - 239
  • [22] Clinical outcomes of benign brain tumors treated with single fraction LINAC-based stereotactic radiosurgery: Experience of a single institute
    Chew, Chia-Hui
    Chen, Jin-Cherng
    Hung, Shih-Kai
    Wu, Tsung-Hsien
    Lee, Moon-Sing
    Chiou, Wen-Yen
    Chen, Liang-Cheng
    Lin, Hon-Yi
    TZU CHI MEDICAL JOURNAL, 2022, 34 (04): : 462 - 472
  • [23] Potential role for LINAC-based stereotactic radiosurgery for the treatment of 5 or more radioresistant melanoma brain metastases
    Frakes, Jessica M.
    Figura, Nicholas B.
    Ahmed, Kamran A.
    Juan, Tzu-Hua
    Patel, Neha
    Latifi, Kujtim
    Sarangkasiri, Siriporn
    Strom, Tobin J.
    Chinnaiyan, Prakash
    Rao, Nikhil G.
    Etame, Arnold B.
    JOURNAL OF NEUROSURGERY, 2015, 123 (05) : 1261 - 1267
  • [24] Hippocampal dose during Linac-based stereotactic radiotherapy for brain metastases: An observational study
    Fiorentino, Alba
    Tebano, Umberto
    Sicignano, Gianluisa
    Ricchetti, Francesco
    Di Paola, Gioacchino
    Aiello, Dario
    Giaj-Levra, Niccolo
    Mazzola, Rosario
    Fersino, Sergio
    Ruggieri, Ruggero
    Alongi, Filippo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 49 : 135 - 138
  • [25] Quality assurance system to correct for errors arising from couch rotation in linac-based stereotactic radiosurgery
    Brezovich, IA
    Pareek, PN
    Plott, WE
    Jennelle, RLS
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (04): : 883 - 890
  • [26] CONFORMITY OF LINAC-BASED STEREOTACTIC RADIOSURGERY USING DYNAMIC CONFORMAL ARCS AND MICRO-MULTILEAF COLLIMATOR
    Hazard, Lisa J.
    Wang, Brian
    Skidmore, Thomas B.
    Chern, Shyh-Shi
    Salter, Bill J.
    Jensen, Randy L.
    Shrieve, Dennis C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (02): : 562 - 570
  • [27] Investigation of irradiated volume in linac-based brain hypo-fractionated stereotactic radiotherapy
    Ruschin, Mark
    Sahgal, Arjun
    Soliman, Hany
    Myrehaug, Sten
    Tsao, May
    Yeboah, Collins
    Sarfehnia, Arman
    Chugh, Brige
    Kiss, Alex
    Lee, Young
    RADIATION ONCOLOGY, 2017, 12
  • [28] Recovery of cranial nerve neuropathies after LINAC-based stereotactic radiosurgery for benign cavernous sinus meningioma
    Kaisman-Elbaz, Tehila
    Blumenfeld, Philip
    Wygoda, Marc
    Feldman, John
    Shoshan, Yigal
    JOURNAL OF NEURO-ONCOLOGY, 2024, 170 (01) : 119 - 128
  • [29] Frameless linac-based stereotactic radiosurgery treatment for SUNCT syndrome targeting the trigeminal nerve and sphenopalatine ganglion
    Tan, Daniel Y. H.
    Chua, Eu Tiong
    Ng, Kim Bock
    Chan, Kwang Ping
    Thomas, John
    CEPHALALGIA, 2013, 33 (13) : 1132 - 1136
  • [30] Proposal for a New Prognostic Score for Linac-Based Radiosurgery in Cerebral Arteriovenous Malformations
    Milker-Zabel, Stefanie
    Kopp-Schneider, Annette
    Wiesbauer, Hannah
    Schlegel, Wolfgang
    Huber, Peter
    Debus, Juergen
    Bois, Angelika Zabel-du
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (02): : 525 - 532