Impact of MRI resolution for Linac-based stereotactic radiosurgery

被引:0
|
作者
Huang, Yimei [1 ]
Liang, Evan [1 ]
Schaff, Eric M. [1 ]
Zhao, Bo [1 ]
Snyder, Karen C. [1 ]
Chetty, Indrin J. [1 ]
Shah, Mira M. [1 ]
Siddiqui, Salim M. [1 ]
机构
[1] Henry Ford Hlth, Dept Radiat Oncol, Detroit, MI 48202 USA
来源
FRONTIERS IN ONCOLOGY | 2023年 / 13卷
关键词
MRI resolution; partial volume; radiosurgery; target definition; plan quality; GAMMA-KNIFE SURGERY; BRAIN METASTASES; RADIATION-THERAPY;
D O I
10.3389/fonc.2023.1090582
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: Magnetic resonance imaging (MRI) is a standard imaging modality in intracranial stereotactic radiosurgery (SRS) for defining target volumes. However, wide disparities in MRI resolution exist, which could directly impact accuracy of target delineation. Here, sequences with various MRI resolution were acquired on phantoms to evaluate the effect on volume definition and dosimetric consequence for cranial SRS.Materials/Methods: Four T1-weighted MR sequences with increasing 3D resolution were compared, including two Spin Echo (SE) 2D acquisitions with 5mm and 3mm slice thickness (SE5mm, SE3mm) and two gradient echo 3D acquisitions (TFE, BRAVO). The voxel sizes were 0.4x0.4x5.0, 0.5x0.5x3.0, 0.9x0.9x1.25, and 0.4x0.4x0.5 mm(3), respectively. Four phantoms with simulated lesions of different shape and volume (range, 0.53-25.0 cm(3)) were imaged, resulting in 16 total sets of MRIs. Four radiation oncologists provided contours on individual MR image set. All observer contours were compared with ground truth, defined on CT image according to the absolute dimensions of the target structure, using Dice similarity coefficient (DSC), Hausdorff distance (HD), mean distance-to-agreement (MDA), and the ratio between reconstructed and true volume (Ratio(vol)). For dosimetric consequence, SRS plans targeting observer volumes were created. The true Paddick conformity index (CIpaddicktrue ), calculated with true target volume, was correlated with quality of observer volume.Results: All measures of observer contours improved as increasingly higher MRI resolution was provided from SE5mm to BRAVO. The improvement in DSC, HD and MDA was statistically significant (p < 0.01). Dosimetrically, CIpaddicktrue strongly correlated with DSC of the planning observer volume (Pearson's r=0.94, p < 0.00001).Conclusions: Significant improvement in target definition and reduced inter observer variation was observed as the MRI resolution improved, which also improved the quality of SRS plans. Results imply that high resolution 3D MR sequences should be used to minimize potential errors in target definition, and multi-slice 2D sequences should be avoided.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] LINAC-based spinal stereotactic radiosurgery
    Hamilton, AJ
    Lulu, BA
    Fosmire, H
    Gossett, L
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1996, 66 (1-3) : 1 - 9
  • [2] Linac-based stereotactic radiosurgery and radiotherapy
    Ayadi, M.
    Ginestet, C.
    Gassa, F.
    Claude, L.
    Mazeron, J. -J.
    BULLETIN DU CANCER, 2010, 97 (07) : 791 - 806
  • [3] Linac-based stereotactic radiosurgery for brain arteriovenous malformations
    Gawish, Ahmed
    Roellich, Burkard
    Ochel, Hans-Joachim
    Brunner, Thomas B.
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [4] Linac-based stereotactic radiosurgery for brain arteriovenous malformations
    Ahmed Gawish
    Burkard Röllich
    Hans-Joachim Ochel
    Thomas B. Brunner
    Radiation Oncology, 17
  • [5] Evaluation of brain edema formation defined by MRI after LINAC-based stereotactic radiosurgery
    Harat, Maciej
    Lebioda, Andrzej
    Lasota, Judyta
    Makarewicz, Roman
    RADIOLOGY AND ONCOLOGY, 2017, 51 (02) : 137 - 141
  • [6] LINAC-based stereotactic radiosurgery radiotherapy for brain metastases in patients with breast cancer
    Gupta, Ankita
    Yadav, Budhi Singh
    Ballari, Nagarjun
    Das, Namrata
    Robert, Ngangom
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (03) : 351 - 359
  • [7] Pediatric cerebral arteriovenous malformations: The role of stereotactic linac-based radiosurgery
    Zabel-Du Bois, Angelika
    Milker-Zabel, Stefanie
    Huber, Peter
    Schlegel, Wolfgang
    Debus, Juergen
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (04): : 1206 - 1211
  • [8] Feasibility of linac-based fractionated stereotactic radiotherapy and stereotactic radiosurgery for patients with up to ten brain metastases
    Hirata, Masanori
    Yasui, Kazuaki
    Oota, Naofumi
    Ogawa, Hirofumi
    Onoe, Tsuyoshi
    Maki, Sayo
    Ito, Yusuke
    Hayashi, Kenji
    Asakura, Hirofumi
    Murayama, Shigeyuki
    Mitsuya, Koichi
    Deguchi, Shoichi
    Nakamura, Katsumasa
    Hayashi, Nakamasa
    Nishimura, Tetsuo
    Harada, Hideyuki
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [9] LINAC-based stereotactic radiosurgery to the brain with concurrent vemurafenib for melanoma metastases
    Ahmed, Kamran A.
    Freilich, Jessica M.
    Sloot, Sarah
    Figura, Nicholas
    Gibney, Geoffrey T.
    Weber, Jeffrey S.
    Sarangkasiri, Siriporn
    Chinnaiyan, Prakash
    Forsyth, Peter A.
    Etame, Arnold B.
    Rao, Nikhil G.
    JOURNAL OF NEURO-ONCOLOGY, 2015, 122 (01) : 121 - 126
  • [10] LINAC-based stereotactic radiosurgery to the brain with concurrent vemurafenib for melanoma metastases
    Kamran A. Ahmed
    Jessica M. Freilich
    Sarah Sloot
    Nicholas Figura
    Geoffrey T. Gibney
    Jeffrey S. Weber
    Siriporn Sarangkasiri
    Prakash Chinnaiyan
    Peter A. Forsyth
    Arnold B. Etame
    Nikhil G. Rao
    Journal of Neuro-Oncology, 2015, 122 : 121 - 126