Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre

被引:14
作者
Zabek, Andrzej [1 ,2 ]
Boczar, Krzysztof [1 ]
Ulman, Mateusz [1 ]
Holcman, Katarzyna [3 ]
Kostkiewicz, Magdalena [2 ,3 ]
Pfitzner, Roman [2 ,4 ]
Debski, Maciej [5 ]
Musial, Robert [6 ]
Lelakowski, Jacek [1 ,2 ]
Malecka, Barbara [1 ,2 ]
机构
[1] John Paul 2 Hosp, Dept Electrocardiol, 80 Pradnicka St, PL-31202 Krakow, Poland
[2] Jagiellonian Univ Med Coll, Inst Cardiol, 12 Swietej Anny St, PL-31008 Krakow, Poland
[3] John Paul 2 Hosp, Dept Cardiac & Vasc Dis, 80 Pradnicka St, PL-31202 Krakow, Poland
[4] John Paul 2 Hosp, Dept Cardiac & Vasc Surg, 80 Pradnicka St, PL-31202 Krakow, Poland
[5] Univ East Anglia, Norfolk & Norwich Univ Hosp, Dept Cardiol, Norwich NR4 7TJ, England
[6] John Paul 2 Hosp, Dept Anesthesiol & Intens Care, Krakow, Poland
来源
EUROPACE | 2023年 / 25卷 / 03期
关键词
cardiac implantable electronic devices; complications; effectiveness; implantable cardioverter-defibrillator; lead; safety; transvenous lead extraction; EXPERT CONSENSUS STATEMENT; CONTROLLED ELECTRA; OUTCOMES; EXPERIENCE; REGISTRY; COIL; PACEMAKER; TRENDS;
D O I
10.1093/europace/euac272
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads with a dwell time of >10 years (Group A) vs. younger leads (Group B) using mechanical extraction systems. Methods and results Between October 2011 and July 2022, we performed TLE in 318 patients. Forty-six (14.4%) extracted ICD leads in 46 (14.5%) patients that had been implanted for >10 years. The median dwell time of all extracted ICD leads was 5.9 years. Cardiovascular implantable electronic device-related infection was an indication for TLE in 31.8% of patients. Complete ICD leads removal and complete procedural success in both groups were similar (95.7% in Group A vs. 99.6% in Group B, P = 0.056% and 95.6% in Group A vs. 99.6% in Group B, P = 0.056, respectively). We did not find a significant difference between major and minor complication rates in both groups (6.5% in Group A vs. 1.5% in Group B and 2.2% in Group A vs. 1.8% in Group B, P = 0.082, respectively). One death associated with the TLE procedure was recorded in Group B. Conclusion The TLE procedures involving the extraction of old ICD leads were effective and safe. The outcomes of ICD lead removal with a dwell time of >10 years did not differ significantly compared with younger ICD leads. However, extraction of older ICD leads required more frequent necessity for utilizing multiple extraction tools, more experience and versatility of the operator, and increased surgery costs.
引用
收藏
页码:1100 / 1109
页数:10
相关论文
共 25 条
  • [1] FRAGILE: FRench Attitude reGistry in case of ICD LEad replacement
    Alonso, Christine
    Marquie, Christelle
    Defaye, Pascal
    Clementy, Nicolas
    Mondoly, Pierre
    Sadoul, Nicolas
    Boveda, Serge
    Hidden-Lucet, Francoise
    Dompnier, Antoine
    Da Costa, Antoine
    Marijon, Eloi
    Leclercq, Christophe
    Caudron, Guillaume
    Piot, Olivier
    Deharo, Jean-Claude
    [J]. EUROPACE, 2021, 23 (03): : 389 - 394
  • [2] 2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS/HRS/LAHRS
    Bongiorni, Maria G.
    Burri, Haran
    Deharo, Jean C.
    Starck, Christoph
    Kennergren, Charles
    Saghy, Laszlo
    Rao, Archana
    Tascini, Carlo
    Lever, Nigel
    Kutarski, Andrzej
    Lozano, Ignacio Fernandez
    Strathmore, Neil
    Costa, Roberto
    Epstein, Laurence
    Love, Charles
    Blomstrom-Lundqvist, Carina
    Fauchier, Laurent
    Defaye, Pascal
    Arnar, David O.
    Klug, Didier
    Boveda, Serge
    Nielsen, Jens Cosedis
    Boriani, Giuseppe
    Zhang, Shu
    Martin, Andrew Paul
    Prutkin, Jordan M.
    de Zuloaga, Claudio
    [J]. EUROPACE, 2018, 20 (07): : 1217 - +
  • [3] The European Lead Extraction ConTRolled (ELECTRa) study: a European Heart Rhythm Association (EHRA) Registry of Transvenous Lead Extraction Outcomes
    Bongiorni, Maria Grazia
    Kennergren, Charles
    Butter, Christian
    Deharo, Jean Claude
    Kutarski, Andrzej
    Rinaldi, Christopher A.
    Romano, Simone L.
    Maggioni, Aldo P.
    Andarala, Maryna
    Auricchio, Angelo
    Kuck, Karl-Heinz
    Blomstrom-Lundqvist, Carina
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 (40) : 2995 - 3005
  • [4] Clinical predictors of adverse patient outcomes in an experience of more than 5000 chronic endovascular pacemaker and defibrillator lead extractions
    Brunner, Michael P.
    Cronin, Edmond M.
    Duarte, Valeria E.
    Yu, Changhong
    Tarakji, Khaldoun G.
    Martin, David O.
    Callahan, Thomas
    Cantillon, Daniel J.
    Niebauer, Mark J.
    Saliba, Walid I.
    Kanj, Mohamed
    Wazni, Oussama
    Baranowski, Bryan
    Wilkoff, Bruce L.
    [J]. HEART RHYTHM, 2014, 11 (05) : 799 - 805
  • [5] Superior Vena Cava Defibrillator Coils Make Transvenous Lead Extraction More Challenging and Riskier
    Epstein, Laurence M.
    Love, Charles J.
    Wilkoff, Bruce L.
    Chung, Mina K.
    Hackler, Joseph W.
    Bongiorni, Maria Grazia
    Segreti, Luca
    Carrillo, Roger G.
    Baltodano, Pablo
    Fischer, Avi
    Kennergren, Charles
    Viklund, Roger
    Mittal, Suneet
    Arshad, Aysha
    Ellenbogen, Kenneth A.
    John, Roy M.
    Maytin, Melanie
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (09) : 987 - 989
  • [6] 16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United States 1993 to 2008
    Greenspon, Arnold J.
    Patel, Jasmine D.
    Lau, Edmund
    Ochoa, Jorge A.
    Frisch, Daniel R.
    Ho, Reginald T.
    Pavri, Behzad B.
    Kurtz, Steven M.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (10) : 1001 - 1006
  • [7] Utilization trends and clinical outcomes in patients implanted with a single- vs a dual-coil implantable cardioverter-defibrillator lead: Insights from the ALTITUDE Study
    Hsu, Jonathan C.
    Saxon, Leslie A.
    Jones, Paul W.
    Wehrenberg, Scott
    Marcus, Gregory M.
    [J]. HEART RHYTHM, 2015, 12 (08) : 1770 - 1775
  • [8] Outcome of transvenous lead extraction of leads older than 20 years
    Issa, Ziad F.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (11) : 3042 - 3048
  • [9] Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of > 10 years
    Kleemann, Thomas
    Becker, Torsten
    Doenges, Klaus
    Vater, Margit
    Senges, Jochen
    Schneider, Steffen
    Saggau, Werner
    Weisse, Udo
    Seidl, Karlheinz
    [J]. CIRCULATION, 2007, 115 (19) : 2474 - 2480
  • [10] 2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction
    Kusumoto, Fred M.
    Schoenfeld, Mark H.
    Wilkoff, Bruce L.
    Berul, Charles I.
    Birgersdotter-Green, Ulrika M.
    Carrillo, Roger
    Cha, Yong-Mei
    Clancy, Jude
    Deharo, Jean-Claude
    Ellenbogen, Kenneth A.
    Exner, Derek
    Hussein, Ayman A.
    Kennergren, Charles
    Krahn, Andrew
    Lee, Richard
    Love, Charles J.
    Madden, Ruth A.
    Mazzetti, Hector Alfredo
    Moore, JoEllyn Carol
    Parsonnet, Jeffrey
    Patton, Kristen K.
    Rozner, Marc A.
    Selzman, Kimberly A.
    Shoda, Morio
    Srivathsan, Komandoor
    Strathmore, Neil F.
    Swerdlow, Charles D.
    Tompkins, Christine
    Wazni, Oussama
    [J]. HEART RHYTHM, 2017, 14 (12) : E503 - +