Evaluation of a New Real-Time Dosimeter Sensor for Interventional Radiology Staff

被引:12
|
作者
Hattori, Kenshin [1 ]
Inaba, Yohei [1 ,2 ]
Kato, Toshiki [1 ]
Fujisawa, Masaki [1 ]
Yasuno, Hikaru [1 ]
Yamada, Ayumi [1 ]
Haga, Yoshihiro [1 ,3 ]
Suzuki, Masatoshi [1 ,2 ]
Zuguchi, Masayuki [1 ]
Chida, Koichi [1 ,2 ]
机构
[1] Tohoku Univ, Grad Sch Med, Course Radiol Technol, Hlth Sci, 2-1 Seiryo,Aoba ku, Sendai 9808575, Japan
[2] Tohoku Univ, Int Res Inst Disaster Sci, Dept Radiat Disaster Med, 468-1 Aramaki Aza Aoba,Aoba ku, Sendai 9800845, Japan
[3] Sendai Kousei Hosp, Dept Radiol, 4-5 Hirose machi,Aoba ku, Sendai 9800873, Japan
关键词
radiation protection and safety; fluoroscopy; interventional radiology (IVR); fluoroscopically guided interventional procedures; percutaneous coronary intervention (PCI); eye lens dose; occupational radiation exposure; X-ray examination; real-time radiation sensor; RADIATION PROTECTION; FOLLOW-UP; EYE; PHYSICIANS; PERFORMANCE; INJURIES; EXPOSURE; EYEWEAR;
D O I
10.3390/s23010512
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In 2011, the International Commission on Radiological Protection (ICRP) recommended a significant reduction in the lens-equivalent radiation dose limit, thus from an average of 150 to 20 mSv/year over 5 years. In recent years, the occupational dose has been rising with the increased sophistication of interventional radiology (IVR); management of IVR staff radiation doses has become more important, making real-time radiation monitoring of such staff desirable. Recently, the i3 real-time occupational exposure monitoring system (based on RaySafe (TM)) has replaced the conventional i2 system. Here, we compared the i2 and i3 systems in terms of sensitivity (batch uniformity), tube-voltage dependency, dose linearity, dose-rate dependency, and angle dependency. The sensitivity difference (batch uniformity) was approximately 5%, and the tube-voltage dependency was <+/- 20% between 50 and 110 kV. Dose linearity was good (R-2 = 1.00); a slight dose-rate dependency (similar to 20%) was evident at very high dose rates (250 mGy/h). The i3 dosimeter showed better performance for the lower radiation detection limit compared with the i2 system. The horizontal and vertical angle dependencies of i3 were superior to those of i2. Thus, i3 sensitivity was higher over a wider angle range compared with i2, aiding the measurement of scattered radiation. Unlike the i2 sensor, the influence of backscattered radiation (i.e., radiation from an angle of 180 degrees) was negligible. Therefore, the i3 system may be more appropriate in areas affected by backscatter. In the future, i3 will facilitate real-time dosimetry and dose management during IVR and other applications.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Real-time dosimeter targeted to nuclear applications
    Correia, Alexandre
    Rosa, Carla C.
    Santos, Pedro M. P.
    Falcao, Antonio N.
    Lorentz, Katharina
    SECOND INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS, 2014, 9286
  • [32] Real-Time Optical Fiber Dosimeter Probe
    Croteau, Andre
    Caron, Serge
    Rink, Alexandra
    Jaffray, David
    Mermut, Ozzy
    OPTICAL FIBERS, SENSORS, AND DEVICES FOR BIOMEDICAL DIAGNOSTICS AND TREATMENT XI, 2011, 7894
  • [33] The Society for Computer Applications in Radiology - Real-time radiology
    Williamson, B
    JOURNAL OF DIGITAL IMAGING, 1999, 12 (01) : 48 - 48
  • [34] DEVELOPMENT OF REAL-TIME RADIATION EXPOSURE DOSIMETRY SYSTEM USING SYNTHETIC RUBY FOR INTERVENTIONAL RADIOLOGY
    Hosokai, Yoshiyuki
    Matsumoto, Kenki
    Kozakai, Masataka
    Takahashi, Kaito
    Usui, Akihito
    Win, Thet Pe
    Muroi, Kenzo
    Saito, Haruo
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (04) : 517 - 522
  • [35] New real-time patient radiation dosimeter for use in radiofrequency catheter ablation
    Kato, Mamoru
    Chida, Koichi
    Nakamura, Masaaki
    Toyoshima, Hideto
    Terata, Ken
    Abe, Yoshihisa
    JOURNAL OF RADIATION RESEARCH, 2019, 60 (02) : 215 - 220
  • [36] Hyperspectral sensor testbed for real-time algorithm evaluation
    Jafolla, J
    Dombrowski, M
    31ST APPLIED IMAGERY PATTERN RECOGNITION WORKSHOP, PROCEEDINGS, 2002, : 85 - 91
  • [37] Hyperspectral sensor testbed for real-time algorithm evaluation
    Jafolla, J
    Dombrowski, M
    IMAGING SPECTROMETRY VII, 2001, 4480 : 345 - 354
  • [38] SENSOR PLACEMENT FOR REAL-TIME INFILTRATION PARAMETER EVALUATION
    IZADI, B
    HEERMANN, DF
    DUKE, HR
    TRANSACTIONS OF THE ASAE, 1988, 31 (04): : 1159 - 1166
  • [39] Occupational doses in interventional angiography after radiological protection training and use of a real-time direct display dosimeter
    Lundvall, Lise-Lott
    Sandborg, Michael
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (03)
  • [40] Evaluation of a real-time semiconductor dosimeter and measurement of finger dose in nuclear medicine departments
    Fujibuchi T.
    Iimori T.
    Masuda Y.
    Uchida Y.
    Isobe T.
    Sakae T.
    Radiological Physics and Technology, 2010, 3 (1) : 53 - 57