Evaluation of a New Real-Time Dosimeter Sensor for Interventional Radiology Staff

被引:12
|
作者
Hattori, Kenshin [1 ]
Inaba, Yohei [1 ,2 ]
Kato, Toshiki [1 ]
Fujisawa, Masaki [1 ]
Yasuno, Hikaru [1 ]
Yamada, Ayumi [1 ]
Haga, Yoshihiro [1 ,3 ]
Suzuki, Masatoshi [1 ,2 ]
Zuguchi, Masayuki [1 ]
Chida, Koichi [1 ,2 ]
机构
[1] Tohoku Univ, Grad Sch Med, Course Radiol Technol, Hlth Sci, 2-1 Seiryo,Aoba ku, Sendai 9808575, Japan
[2] Tohoku Univ, Int Res Inst Disaster Sci, Dept Radiat Disaster Med, 468-1 Aramaki Aza Aoba,Aoba ku, Sendai 9800845, Japan
[3] Sendai Kousei Hosp, Dept Radiol, 4-5 Hirose machi,Aoba ku, Sendai 9800873, Japan
关键词
radiation protection and safety; fluoroscopy; interventional radiology (IVR); fluoroscopically guided interventional procedures; percutaneous coronary intervention (PCI); eye lens dose; occupational radiation exposure; X-ray examination; real-time radiation sensor; RADIATION PROTECTION; FOLLOW-UP; EYE; PHYSICIANS; PERFORMANCE; INJURIES; EXPOSURE; EYEWEAR;
D O I
10.3390/s23010512
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In 2011, the International Commission on Radiological Protection (ICRP) recommended a significant reduction in the lens-equivalent radiation dose limit, thus from an average of 150 to 20 mSv/year over 5 years. In recent years, the occupational dose has been rising with the increased sophistication of interventional radiology (IVR); management of IVR staff radiation doses has become more important, making real-time radiation monitoring of such staff desirable. Recently, the i3 real-time occupational exposure monitoring system (based on RaySafe (TM)) has replaced the conventional i2 system. Here, we compared the i2 and i3 systems in terms of sensitivity (batch uniformity), tube-voltage dependency, dose linearity, dose-rate dependency, and angle dependency. The sensitivity difference (batch uniformity) was approximately 5%, and the tube-voltage dependency was <+/- 20% between 50 and 110 kV. Dose linearity was good (R-2 = 1.00); a slight dose-rate dependency (similar to 20%) was evident at very high dose rates (250 mGy/h). The i3 dosimeter showed better performance for the lower radiation detection limit compared with the i2 system. The horizontal and vertical angle dependencies of i3 were superior to those of i2. Thus, i3 sensitivity was higher over a wider angle range compared with i2, aiding the measurement of scattered radiation. Unlike the i2 sensor, the influence of backscattered radiation (i.e., radiation from an angle of 180 degrees) was negligible. Therefore, the i3 system may be more appropriate in areas affected by backscatter. In the future, i3 will facilitate real-time dosimetry and dose management during IVR and other applications.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Radiation Dose Reduction Using Real-Time Image Processing in Interventional Radiology
    Kanal, K.
    Moirano, J.
    Zamora, D.
    Stewart, B.
    MEDICAL PHYSICS, 2016, 43 (06) : 3347 - 3347
  • [22] Personnel real time dosimetry in interventional radiology
    Servoli, L.
    Bissi, L.
    Fabiani, S.
    Magalotti, D.
    Placidi, P.
    Scorzoni, A.
    Calandra, A.
    Cicioni, R.
    Chiocchini, S.
    Dipilato, A. C.
    Forini, N.
    Paolucci, M.
    Di Lorenzo, R.
    Cappotto, F. P.
    Scarpignato, M.
    Maselli, A.
    Pentiricci, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12): : 1724 - 1730
  • [23] A real-time pulsed photon dosimeter
    Brown, D
    Olsher, RH
    Eisen, Y
    Rodriguez, JF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 373 (01): : 139 - 147
  • [24] Dose Evaluation in Medical Staff during Interventional Radiology Procedures
    Bacchim Neto, F. A.
    Alves, A. F. F.
    Alvarez, M.
    Rosa, M. E. D.
    Macedo de Freitas, C. C.
    Moura, R.
    Pina, D. R.
    Miranda, J. R. A.
    VI LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2014), 2014, 49 : 927 - 930
  • [25] Real-time radiology in the microscale
    Hwu, Y
    Je, JH
    Margaritondo, G
    CHINESE JOURNAL OF PHYSICS, 2005, 43 (01) : 285 - 292
  • [26] Real-time radiology in the microscale
    Hwu, Y
    Je, JH
    Margaritondo, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 551 (01): : 108 - 118
  • [27] Real-time PC based X-ray simulation for interventional radiology training
    Muniyandi, M
    Cotin, S
    Srinivasan, M
    Dawson, S
    MEDICINE MEETS VIRTUAL REALITY 11: NEXTMED: HEALTH HORIZON, 2003, 94 : 233 - 239
  • [28] Dynamic real-time sensor performance evaluation
    Sudano, JJ
    PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON INFORMATION FUSION, VOL I, 2002, : 361 - 365
  • [29] A new real-time personal dosimeter with position monitoring based on a scintillator
    Moon, Sun Young
    Yoon, Myonggeun
    Kim, Sun-Young
    Shin, Dongho
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2021, 78 (11) : 1133 - 1140
  • [30] A new real-time personal dosimeter with position monitoring based on a scintillator
    Sun Young Moon
    Myonggeun Yoon
    Sun-Young Kim
    Dongho Shin
    Journal of the Korean Physical Society, 2021, 78 : 1133 - 1140