The evolution of robotic systems for total knee arthroplasty, each system must be assessed for its own value: a systematic review of clinical evidence and meta-analysis

被引:26
作者
Vermue, Hannes [1 ]
Batailler, Cecile [2 ]
Monk, Paul [3 ,6 ]
Haddad, Fares [4 ]
Luyckx, Thomas [5 ]
Lustig, Sebastien [2 ]
机构
[1] Univ Hosp Ghent, Dept Orthopaed Surg, Ghent, Belgium
[2] Univ Hosp Ctr Lyon, Dept Orthopaed Surg, Lyon, France
[3] Auckland City Hosp, Dept Orthopaed Surg, Grafton, New Zealand
[4] Univ Coll Hosp, Dept Trauma & Orthopaed, London, England
[5] AZ Delta, Dept Orthopaed Surg, Roeselare, Belgium
[6] Univ Auckland, Auckland Bioengn Inst, Grafton, New Zealand
关键词
Patient outcomes; Radiological assessment; Robotic surgical procedure; Total knee replacement; ALIGNMENT; BALANCE; SURGERY; TIME;
D O I
10.1007/s00402-022-04632-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Robotic systems have been introduced to improve the precision of total knee arthroplasty. However, different robotic systems are available, each with unique features used to plan and execute the surgery. As such, due to this diversity, the clinical evaluation of each robotic platform should be separated. Methods An extensive literature search of PubMed, Medline, Embase and Web of Science was conducted with subsequent meta-analysis. Randomised controlled trials, comparative studies, and cohort studies were included regarding robot-assisted total knee arthroplasty. Evaluated outcomes included clinical results, surgical precision, ligament balance, surgical time, learning curve, complications and revision rates. These were split up based on the robot-specific brand: ROBODOC (T-SOLUTION ONE), OMNIBOT, MAKO, NAVIO (CORI) and ROSA. Results With a follow-up of more than 10 years, no improved clinical outcomes have been noted with the ROBODOC system compared to the conventional technique. If available, other platforms only present short-term clinical outcomes. Radiological outcomes are published for most robotic setups, demonstrating improved surgical precision compared to the conventional technique. Gap balance assessment is performed differently between all systems, leading to heterogeneous outcomes regarding its relationship on clinical outcomes. There is a similar learning curve based on operative time for all robotic platforms. In most studies, robot assistance requires longer operative time compared to the conventional technique. Complications and revision rates are published for ROBODOC and MAKO, without clear differences to conventional total knee arthroplasty. Conclusion The main finding of this systematic review is that the current evidence regarding each robotic system is diverse in quantity and quality. Each system has its own specificities and must be assessed for its own value. Regarding scientific literature, the generic term of robotic should be banned from the general conclusion.
引用
收藏
页码:3369 / 3381
页数:13
相关论文
共 67 条
  • [21] Robotic-arm assisted total knee arthroplasty has a learning curve of seven cases for integration into the surgical workflow but no learning curve effect for accuracy of implant positioning
    Kayani, Babar
    Konan, S.
    Huq, S. S.
    Tahmassebi, J.
    Haddad, F. S.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) : 1132 - 1141
  • [22] Iatrogenic Bone and Soft Tissue Trauma in Robotic-Arm Assisted Total Knee Arthroplasty Compared With Conventional Jig-Based Total Knee Arthroplasty: A Prospective Cohort Study and Validation of a New Classification System
    Kayani, Babar
    Konan, Sujith
    Pietrzak, Jurek R. T.
    Haddad, Fares S.
    [J]. JOURNAL OF ARTHROPLASTY, 2018, 33 (08) : 2496 - 2501
  • [23] Keggi J., 2017, BR EDITOR SOC BONE J, V99, P59
  • [24] Impact of intra-operative predictive ligament balance on post-operative balance and patient outcome in TKA: a prospective multicenter study
    Keggi, John M.
    Wakelin, Edgar A.
    Koenig, Jan A.
    Lawrence, Jeffrey M.
    Randall, Amber L.
    Ponder, Corey E.
    DeClaire, Jeffrey H.
    Shalhoub, Sami
    Lyman, Stephen
    Plaskos, Christopher
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) : 2165 - 2174
  • [25] Patient-Reported Functional and Satisfaction Outcomes after Robotic-Arm-Assisted Total Knee Arthroplasty: Early Results of a Prospective Multicenter Investigation
    Khlopas, Anton
    Sodhi, Nipun
    Hozack, William J.
    Chen, Antonia F.
    Mahoney, Ormonde M.
    Kinsey, Tracy
    Orozco, Fabio
    Mont, Michael A.
    [J]. JOURNAL OF KNEE SURGERY, 2020, 33 (07) : 685 - 690
  • [26] Does Robotic-assisted TKA Result in Better Outcome Scores or Long-Term Survivorship Than Conventional TKA? A Randomized, Controlled Trial
    Kim, Young-Hoo
    Yoon, Sung-Hwan
    Park, Jang-Won
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2020, 478 (02) : 266 - 275
  • [27] Assessment of Limb Alignment and Component Placement After All Burr Robotic-Assisted TKA
    Laddha, Mukesh
    Gaurav, Sahu
    [J]. INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (SUPPL 1) : 69 - 75
  • [28] Can a robot help a surgeon to predict a good total knee arthroplasty?
    Lee, G-C
    Wakelin, E.
    Randall, A.
    Plaskos, C.
    [J]. BONE & JOINT JOURNAL, 2021, 103B (06) : 67 - 73
  • [29] Liow MHL, 2017, SICOT-J, V3, DOI 10.1051/sicotj/2017052
  • [30] Robotic-assisted total knee arthroplasty may lead to improvement in quality-of-life measures: a 2-year follow-up of a prospective randomized trial
    Liow, Ming Han Lincoln
    Goh, Graham Seow-Hng
    Wong, Merng Koon
    Chin, Pak Lin
    Tay, Darren Keng-Jin
    Yeo, Seng-Jin
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (09) : 2942 - 2951