The evolution of robotic systems for total knee arthroplasty, each system must be assessed for its own value: a systematic review of clinical evidence and meta-analysis

被引:26
作者
Vermue, Hannes [1 ]
Batailler, Cecile [2 ]
Monk, Paul [3 ,6 ]
Haddad, Fares [4 ]
Luyckx, Thomas [5 ]
Lustig, Sebastien [2 ]
机构
[1] Univ Hosp Ghent, Dept Orthopaed Surg, Ghent, Belgium
[2] Univ Hosp Ctr Lyon, Dept Orthopaed Surg, Lyon, France
[3] Auckland City Hosp, Dept Orthopaed Surg, Grafton, New Zealand
[4] Univ Coll Hosp, Dept Trauma & Orthopaed, London, England
[5] AZ Delta, Dept Orthopaed Surg, Roeselare, Belgium
[6] Univ Auckland, Auckland Bioengn Inst, Grafton, New Zealand
关键词
Patient outcomes; Radiological assessment; Robotic surgical procedure; Total knee replacement; ALIGNMENT; BALANCE; SURGERY; TIME;
D O I
10.1007/s00402-022-04632-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Robotic systems have been introduced to improve the precision of total knee arthroplasty. However, different robotic systems are available, each with unique features used to plan and execute the surgery. As such, due to this diversity, the clinical evaluation of each robotic platform should be separated. Methods An extensive literature search of PubMed, Medline, Embase and Web of Science was conducted with subsequent meta-analysis. Randomised controlled trials, comparative studies, and cohort studies were included regarding robot-assisted total knee arthroplasty. Evaluated outcomes included clinical results, surgical precision, ligament balance, surgical time, learning curve, complications and revision rates. These were split up based on the robot-specific brand: ROBODOC (T-SOLUTION ONE), OMNIBOT, MAKO, NAVIO (CORI) and ROSA. Results With a follow-up of more than 10 years, no improved clinical outcomes have been noted with the ROBODOC system compared to the conventional technique. If available, other platforms only present short-term clinical outcomes. Radiological outcomes are published for most robotic setups, demonstrating improved surgical precision compared to the conventional technique. Gap balance assessment is performed differently between all systems, leading to heterogeneous outcomes regarding its relationship on clinical outcomes. There is a similar learning curve based on operative time for all robotic platforms. In most studies, robot assistance requires longer operative time compared to the conventional technique. Complications and revision rates are published for ROBODOC and MAKO, without clear differences to conventional total knee arthroplasty. Conclusion The main finding of this systematic review is that the current evidence regarding each robotic system is diverse in quantity and quality. Each system has its own specificities and must be assessed for its own value. Regarding scientific literature, the generic term of robotic should be banned from the general conclusion.
引用
收藏
页码:3369 / 3381
页数:13
相关论文
共 67 条
  • [1] Combining load sensor and robotic technologies for ligament balance in total knee arthroplasty
    Bardou-Jacquet, Julien
    Murgier, Jerome
    Laudet, Francois
    Fabre, Thierry
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (05)
  • [2] New Technologies in Knee Arthroplasty: Current Concepts
    Batailler, Cecile
    Swan, John
    Sappey Marinier, Elliot
    Servien, Elvire
    Lustig, Sebastien
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (01) : 1 - 18
  • [3] The successful implementation of the Navio robotic technology required 29 cases
    Bell, Courtney
    Grau, Luis
    Orozco, Fabio
    Ponzio, Danielle
    Post, Zachary
    Czymek, Miranda
    Ong, Alvin
    [J]. JOURNAL OF ROBOTIC SURGERY, 2022, 16 (03) : 495 - 499
  • [4] Robotic-assisted total knee arthroplasty demonstrates decreased postoperative pain and opioid usage compared to conventional total knee arthroplasty
    Bhimani, S. J.
    Bhimani, R.
    Smith, A.
    Eccles, C.
    Smith, L.
    Malkani, A.
    [J]. BONE & JOINT OPEN, 2020, 1 (02): : 8 - 12
  • [5] Patient expectations and satisfaction in robotic-assisted total knee arthroplasty: a prospective two-year outcome study
    Blum, Christopher L.
    Lepkowsky, Eric
    Hussein, Adil
    Wakelin, Edgar A.
    Plaskos, Christopher
    Koenig, Jan A.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) : 2155 - 2164
  • [6] Preliminary experience with an image-free handheld robot for total knee arthroplasty: 77 cases compared with a matched control group
    Bollars, P.
    Boeckxstaens, A.
    Mievis, J.
    Kalaai, S.
    Schotanus, M. G. M.
    Janssen, D.
    [J]. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (04) : 723 - 729
  • [7] Functional alignment achieves soft-tissue balance in total knee arthroplasty as measured with quantitative sensor-guided technology
    Chang, J. S.
    Kayani, B.
    Wallace, C.
    Haddad, F. S.
    [J]. BONE & JOINT JOURNAL, 2021, 103B (03) : 507 - 514
  • [8] Robotic versus conventional primary total knee arthroplasty: clinical and radiological long-term results with a minimum follow-up of ten years
    Cho, Kyu-Jin
    Seon, Jong-Keun
    Jang, Won-Young
    Park, Chun-Gon
    Song, Eun-Kyoo
    [J]. INTERNATIONAL ORTHOPAEDICS, 2019, 43 (06) : 1345 - 1354
  • [9] Clark T C., 2013, ISRN Orthop, V2013, P1, DOI DOI 10.1155/2013/794827
  • [10] A 90-day episode-of-care cost analysis of robotic-arm assisted total knee arthroplasty
    Cool, Christina L.
    Jacofsky, David J.
    Seeger, Kelly A.
    Sodhi, Nipun
    Mont, Michael A.
    [J]. JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2019, 8 (05) : 327 - 336