Evaluating the behavior and bond properties of FRP spike anchors under confined conditions and elevated temperature

被引:5
作者
Khorasani, Mehdi [1 ,2 ,3 ,4 ]
Muciaccia, Giovanni [2 ]
Consiglio, Andrea Nino [2 ]
Mostofinejad, Davood [1 ]
机构
[1] Isfahan Univ Technol IUT, Dept Civil Engn, Esfahan 8415683111, Iran
[2] Politecn Milan, Dept Civil & Environm Engn, I-20133 Milan, Italy
[3] Dept Civil & Environm Engn, Politecn Milano, Milan, Italy
[4] Isfahan Univ Technol IUT, Dept Civil Engn, Esfahan, Iran
关键词
FRP anchors; FRP Spike anchors; Strengthening; Confined conditions; Elevated temperature; DESIGN; BEAMS; PERFORMANCE; COMPOSITES; STRENGTH; FAILURE; FAN;
D O I
10.1016/j.compstruct.2023.117407
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The use of fiber-reinforced polymer (FRP) anchors in combination with the conventional externally bonded reinforcement (EBR) installation technique is an effective method to prevent or postpone the debonding of FRP sheets. However, their behavior under confined conditions and elevated temperatures is still unknown. In such a framework, in the first phase, the current research aims to assess pullout test results for single FRP anchors with dowels ranging from 50 to 75 mm in confined and unconfined conditions. To achieve this goal, three concrete slabs with the dimension of 1550 x 1250 x 250 mm3 were cast. Experimental results showed that the bond strength of FRP anchors in confined conditions increased by about 50% compared to the unconfined conditions. Additionally, a comparison was made between the experimental results and the literature models. In the second phase, eleven pullout tests were conducted on the cylindrical specimens with the dimension of 150 x 200 mm2 (diameter x height) under confined conditions and elevated temperatures by considering different sustained load levels.The results showed as the temperature increases and FRP anchor is constantly loaded, it fails in a shorter time before the adhesive reaches its glass transition. Finally, a bond strength vs. temperature model was developed for FRP anchors in confined conditions and high temperatures.
引用
收藏
页数:16
相关论文
共 96 条
  • [1] Behavior of GFRP strengthening masonry walls using glass fiber composite anchors
    Abdulsalam, Bahira
    Ali, Ahmed H.
    ElSafty, Adel
    Elshafey, Nasser
    [J]. STRUCTURES, 2021, 29 : 1352 - 1361
  • [2] Effect of bond degradation on fire resistance of FRP-strengthened reinforced concrete beams
    Ahmed, A.
    Kodur, V. K. R.
    [J]. COMPOSITES PART B-ENGINEERING, 2011, 42 (02) : 226 - 237
  • [3] Experimental and analytical assessment of different anchorage systems used for CFRP flexurally retrofitted exterior RC beam-column connections
    Akhlaghi, Alireza
    Mostofinejad, Davood
    [J]. STRUCTURES, 2020, 28 : 881 - 893
  • [4] Strength of Carbon Fiber-Reinforced Polymer (CFRP ) Sheets Bonded to Concrete with CFRP Spike Anchors
    Al-Sammari, Alaa T.
    Brena, Sergio F.
    [J]. ACI STRUCTURAL JOURNAL, 2021, 118 (01) : 153 - 166
  • [5] AlMahaidi R, 2018, REHABILITATION OF CONCRETE STRUCTURES WITH FIBER-REINFORCED POLYMER, P1
  • [6] Hysteretic behavior of RC shear walls strengthened with CFRP strips
    Altin, Sinan
    Anil, Ozgur
    Kopraman, Yagmur
    Kara, M. Emin
    [J]. COMPOSITES PART B-ENGINEERING, 2013, 44 (01) : 321 - 329
  • [7] (American Concrete Institute), 2001, ACI349-01. ACI
  • [8] [Anonymous], 2001, JSCEE541
  • [9] [Anonymous], 2008, Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures
  • [10] [Anonymous], 2004, BS-EN1994-1-1