Validation of a single-use and reusable home sleep apnea test based on peripheral arterial tonometry compared to laboratory polysomnography for the diagnosis of obstructive sleep apnea

被引:3
作者
Lyne, Christopher J. [1 ]
Hamilton, Garun S. [1 ,2 ]
Turton, Anthony R. E. [1 ]
Stupar, Durda [1 ]
Mansfield, Darren R. [1 ,3 ,4 ]
机构
[1] Monash Hlth, Monash Lung Sleep Allergy & Immunol, Clayton, Vic, Australia
[2] Monash Univ, Sch Clin Sci, Clayton, Vic, Australia
[3] Monash Univ, Turner Inst Brain & Mental Hlth, Clayton, Vic, Australia
[4] Monash Med Ctr, Monash Lung Sleep Allergy & Immunol, 246 Clayton Rd, Clayton, Vic 3168, Australia
来源
JOURNAL OF CLINICAL SLEEP MEDICINE | 2023年 / 19卷 / 08期
关键词
home sleep apnea testing; polysomnography; obstructive sleep apnea; peripheral arterial tonometry; AMERICAN ACADEMY; OUTCOMES;
D O I
10.5664/jcsm.10568
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: The objective of this study was to independently validate a disposable and a reusable home sleep apnea test (HSAT) recording on peripheral arterial tonometry, compared to laboratory polysomnography (PSG), for the diagnosis of obstructive sleep apnea (OSA).Methods: 115 participants undergoing PSG for suspected OSA were recruited and fitted with the two study devices (NightOwl, Ectosense, Belgium). After exclusions were applied and device failures were removed, data from 100 participants were analyzed. HSAT-derived apnea-hypopnea index (AHI), OSA severity category, total sleep time, and oxygen desaturation index 3% were compared to PSG.Results: Both study devices demonstrated satisfactory levels of agreement with minimal mean bias for determination of AHI and oxygen desaturation index 3% (disposable: AHI mean bias 2.04 events/h [95% limits of agreement-20.9 to 25.0], oxygen desaturation index 3% mean bias-0.21/h [-18.1 to 17.7]; reusable: AHI mean bias 2.91 events/h [-16.9 to 22.7], oxygen desaturation index 3% mean bias 0.77/h [-15.7 to 17.3]). Level of agreement diminished at higher AHI levels although misclassification for severe OSA occurred infrequently. Total sleep time level of agreement for the reusable HSAT was also satisfactory with minimal mean bias (4.18 minutes,-125.1 to 112.4), but the disposable HSAT was impacted by studies with high signal rejection (23.7 minutes,-132.7 to 180.1). Categorization of OSA severity demonstrated moderate agreement with laboratory PSG, with a kappa of 0.52 and 0.57 for the disposable and reusable HSATs respectively.Conclusions: The two HSAT devices were comparable and performed well compared to laboratory PSG for the diagnosis of OSA.Clinical Trial Registration: Registry: Australian New Zealand Clinical Trials Registry; Identifier: ANZCTR12621000444886.
引用
收藏
页码:1429 / 1435
页数:7
相关论文
共 50 条
  • [21] Hypoglossal nerve stimulation therapy on peripheral arterial tonometry in obstructive sleep apnea: a pilot study
    Ikeda, Allison K.
    Li, Qiao
    Quyuumi, Arshed A.
    Dedhia, Raj C.
    SLEEP AND BREATHING, 2019, 23 (01) : 153 - 160
  • [22] The Effect of Surgical Therapy for Obstructive Sleep Apnea on Blood Pressure and Peripheral Arterial Tonometry
    Tangutur, Akshay
    Cai, Yi
    Seay, Everett G.
    Thaler, Erica R.
    Keenan, Brendan T.
    Dedhia, Raj C.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2024, 171 (01) : 286 - 294
  • [23] Comparison of polysomnography, sleep apnea screening test and cardiopulmonary coupling in the diagnosis of pediatric obstructive sleep apnea syndrome
    Zhai, Feng
    Li, Yanbo
    Chen, Jie
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2021, 149
  • [24] A validation study of an esophageal probe–based polygraph against polysomnography in obstructive sleep apnea
    Thorarinn Arnar Olafsson
    Eivind Andreas Steinsvik
    Gregor Bachmann-Harildstad
    Harald Hrubos-Strøm
    Sleep and Breathing, 2022, 26 : 575 - 584
  • [25] Validation of sleep-staging accuracy for an in-home sleep electroencephalography device compared with simultaneous polysomnography in patients with obstructive sleep apnea
    Seol, Jaehoon
    Chiba, Shigeru
    Kawana, Fusae
    Tsumoto, Saki
    Masaki, Minori
    Tominaga, Morie
    Amemiya, Takashi
    Tani, Akihiro
    Hiei, Tetsuro
    Yoshimine, Hiroyuki
    Kondo, Hideaki
    Yanagisawa, Masashi
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [26] An Economic Evaluation of Home Versus Laboratory-Based Diagnosis of Obstructive Sleep Apnea
    Kim, Richard D.
    Kapur, Vishesh K.
    Redline-Bruch, Julie
    Rueschman, Michael
    Auckley, Dennis H.
    Benca, Ruth M.
    Foldvary-Schafer, Nancy R.
    Iber, Conrad
    Zee, Phyllis C.
    Rosen, Carol L.
    Redline, Susan
    Ramsey, Scott D.
    SLEEP, 2015, 38 (07) : 1027 - 1037
  • [27] Night-to-night variability in obstructive sleep apnea using peripheral arterial tonometry: a case for multiple night testing
    Tschopp, Samuel
    Wimmer, Wilhelm
    Caversaccio, Marco
    Borner, Urs
    Tschopp, Kurt
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2021, 17 (09): : 1751 - 1758
  • [28] Validation of the Apnea Risk Evaluation System (ARES) Device Against Laboratory Polysomnography in Pregnant Women at Risk for Obstructive Sleep Apnea Syndrome
    Sharkey, Katherine M.
    Waters, Kelly
    Millman, Richard P.
    Moore, Robin
    Martin, Susan M.
    Bourjeily, Ghada
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2014, 10 (05): : 497 - 502
  • [29] Validation of a portable monitor compared with polysomnography for screening of obstructive sleep apnea in polio survivors
    Ding, Qidi
    Liu, Jianghua
    Wu, Jinxian
    Du, Juan
    Li, Xiao
    Wang, Meng
    Sun, Yunliang
    Yu, Yan
    Wang, Jingyu
    Sun, Ting
    Zhang, Chi
    Lv, Changjun
    Strohl, Kingman P.
    Han, Fang
    Dong, Xiaosong
    FRONTIERS IN NEUROLOGY, 2023, 14
  • [30] A validation study of an esophageal probe-based polygraph against polysomnography in obstructive sleep apnea
    Olafsson, Thorarinn Arnar
    Steinsvik, Eivind Andreas
    Bachmann-Harildstad, Gregor
    Hrubos-Strom, Harald
    SLEEP AND BREATHING, 2022, 26 (02) : 575 - 584