Experimental Study on the Film Cooling Characteristics of Three Complex Tip Structures

被引:2
|
作者
Lin, Juqiang [1 ,3 ]
Li, Haiwang [2 ,3 ]
You, Ruquan [2 ,3 ]
Liu, Runzhou [1 ,3 ]
Tao, Zhi [1 ,3 ]
Liu, Song [2 ,4 ]
机构
[1] Beihang Univ, Sch Energy & Power Engn, Beijing 100191, Peoples R China
[2] Beihang Univ, Res Inst Aeroengines, Beijing 100191, Peoples R China
[3] Natl Key Lab Sci & Technol Aero Engines Aerothermo, Beijing 100191, Peoples R China
[4] AECC Sichuan Gas Turbine Estab, Chengdu 610500, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
film cooling; tip structure; pressure-sensitive paint; leakage flow; GAS-TURBINE BLADE; HEAT-TRANSFER COEFFICIENTS; SQUEALER TIP; FLOW;
D O I
10.1007/s11630-023-1831-x
中图分类号
O414.1 [热力学];
学科分类号
摘要
The turbine blades of aircrafts must be properly cooled to prevent engine failure. Thus, to investigate the influence of the tip structure on the film cooling effect, pressure-sensitive paint test technology was used to determine the adiabatic film cooling effectiveness in this study. The experiment was completed in a cascade comprising three straight blades. The effects of the blowing ratio, density ratio, tip clearance, and tip structure on film cooling efficiency were analyzed. The experimental results demonstrated that, as the blowing ratio increased, the film coverage area and film cooling efficiency increased under most experimental conditions. However, the film cooling efficiency was found to initially increase, and subsequently decrease, as the blowing ratio increased. The respective influences of the density ratio and tip clearance on the film cooling efficiency were found to be significant. The density ratio experiments revealed that a high-density ratio can result in better film coverage than the low-density-ratio air. The tip clearance experimental results indicated that a small tip clearance promotes an increase in film cooling efficiency; this is because the small tip clearance negatively affects the main stream leakage flow, which can reduce the film coverage area. Under the conditions of the Base case 2 configuration, a blowing ratio of 2.1, and a tip clearance of 0.6%h, the average film cooling efficiency of the blade tip was 0.22. Among the three blade tip structures applied in this study, Base case 2 demonstrated higher film cooling efficiency than the other two blade tip structures under the conditions of the same blowing ratio, tip clearance, and density ratio.
引用
收藏
页码:1378 / 1392
页数:15
相关论文
共 50 条
  • [1] Experimental Study on the Film Cooling Characteristics of Three Complex Tip Structures
    LIN Juqiang
    LI Haiwang
    YOU Ruquan
    LIU Runzhou
    TAO Zhi
    LIU Song
    JournalofThermalScience, 2023, 32 (04) : 1378 - 1392
  • [2] Experimental Study on the Film Cooling Characteristics of Three Complex Tip Structures
    Juqiang Lin
    Haiwang Li
    Ruquan You
    Runzhou Liu
    Zhi Tao
    Song Liu
    Journal of Thermal Science, 2023, 32 : 1378 - 1392
  • [3] Experimental and Numerical Evaluation of the Film Cooling Characteristics of the Multicavity Tip With Inclined Film Holes
    Jia, Zhe
    Li, Feng
    Zhang, Weixin
    Liu, Zhao
    Feng, Zhenping
    ASME JOURNAL OF HEAT AND MASS TRANSFER, 2024, 146 (07):
  • [4] Experimental study on film cooling at rotating flat blade tip
    Wu, Hong-Wei
    Ding, Shui-Ting
    Cao, Yu-Zhang
    Tao, Zhi
    2001, Beijing University of Aeronautics and Astronautics (BUAA) (27):
  • [5] Experimental study on cooling characteristics of film cooling with trapezoid tabs
    College of Power and Energy Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
    Hangkong Dongli Xuebao, 2008, 9 (1660-1665):
  • [6] Experimental study of film cooling characteristics of annular cascade endwall with a partitioned film cooling layout
    Zhang, Jie
    Liu, Cunliang
    Zhang, Li
    Zhou, Tianliang
    Li, Lin
    Guo, Yuhang
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 182
  • [7] INFLUENCE OF PASSAGE FLOW ON TIP FILM COOLING CHARACTERISTICS
    Wang, Jin
    Yu, Yong
    Zeng, M.
    Wang, Q. W.
    PROCEEDINGS OF THE ASME TURBO EXPO 2012, VOL 4, PTS A AND B, 2012, : 1389 - 1396
  • [8] Study on Aerodynamic and Cooling Performance of Turbine Blade Squealer Tip with Film Cooling Pulsation Characteristics Considered
    Xu C.
    Li Z.
    Li J.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2022, 56 (05): : 127 - 140
  • [9] Experimental Investigation on Film Cooling Characteristics of Conical Holes on a Turbine Blade Tip in Transonic Flow
    Zhang, Bo-Lun
    Xia, Jun
    Shen, Zhi-Qiang
    Zhu, Hui-Ren
    Tuijin Jishu/Journal of Propulsion Technology, 2023, 44 (08):
  • [10] Comparisons of blade tip phantom cooling effectiveness for two tip structures with three tip clearances
    Li, Feng
    Wang, Haifeng
    Liu, Zhao
    Feng, Zhenping
    Shi, Yan
    APPLIED THERMAL ENGINEERING, 2022, 202