ERP evaluation of EEG signals for monitoring anesthesia depth during surgery

被引:0
作者
Bouafif, Lamia [1 ]
机构
[1] Univ Tunis Manar, Natl Inst Med Studies Tunis, Image & Signal Proc Lab, Tunis 2092, Tunisia
关键词
Anesthesia; Bi spectral analysis; EEG; AEP; ERP; Auditory nerve stimulation; BISPECTRAL INDEX; EVOKED-POTENTIALS; ELECTROENCEPHALOGRAM; INDUCTION; SEDATION; PROPOFOL;
D O I
10.15419/bmrat.v10i10.841
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: In medicine, general anesthesia during surgery involves the administration of pharmacological (hypnotic) agents and clinical monitoring via the analysis of the patient's nervous systems (loss of consciousness and reactivity) during stimulation. Unfortunately, this clinical monitoring is complicated by factors such as curarization, shock, and drugs that block cardiovascular responsiveness. Additionally, inadequate anesthesia due to over-or underdosing increases morbidity rates, such as hypotension and respiratory depression in the case of overdose, and memorization, movement, hypertension, tachycardia, laryngospasm, and bronchospasm in the case of underdosing. Several anesthesia monitoring tools have been introduced to address this issue, such as bispectral analysis (BIS), auditory evoked potential (AEP), q-CON, and entropy monitors; however, these instruments are complicated by accuracy, noise, artifacts, and their correlation with hypnotics. Methods: Noninvasive anesthesia monitoring methods include lower esophageal sphincter, AEP, entropy, and spontaneous electroencephalography (EEG), which is the most commonly used. This method involves BIS of the collected EEG signals and correlates well with consciousness and sedation scores regardless of the anesthetic agents used. In this paper, we present a noninvasive method for monitoring the depth of anesthesia during surgery using the AEP and BIS method. This study aimed to reduce artifacts, optimize the hypnotics/analgesics dosage, limit the effects of pharmacological use, and ensure a better quality recovery. Results: We applied two techniques, BIS and event-related potential (ERP), following multiple stimuli to determine the best anesthesia monitoring approach. A comparative study of the EEG signals showed that measuring cortical responses by ERP provided more precise data in space and time regarding the sedation state of the patient and better monitoring of the hypnotic dose. The BIS method was simpler and easier to implement; however, only average and static values regarding the sleep rate could be obtained. Conclusion: BIS and ERP appear suitable for monitoring sedation and hypnotic dosage during anesthesia, with the best reliability rates and speed with a latency of <4 ms and an accuracy of 92%.
引用
收藏
页码:5995 / 6008
页数:14
相关论文
共 32 条
[1]  
Anderson Nicholas R, 2008, Am J Electroneurodiagnostic Technol, V48, P166
[2]  
[Anonymous], 2006, ANESTHESIOLOGY, V104, P847
[3]   Electro-encephalography [J].
Biasiucci, Andrea ;
Franceschiello, Benedetta ;
Murray, Micah M. .
CURRENT BIOLOGY, 2019, 29 (03) :R80-R85
[4]  
Billard V, 2016, Anesthesia & Reanimation, V2, P23
[5]  
Billiard M, 1994, Normal and pathological sleep: sleep and wake disorders
[6]  
Caparos M, 2010, Nancy Center for Automatic Research CNRS-UMR report 7039
[7]   Monitoring depth of anesthesia - With emphasis on the application of the bispectral index and the middle latency auditory evoked response to the prevention of recall [J].
Drummond, JC .
ANESTHESIOLOGY, 2000, 93 (03) :876-882
[8]   The Technology of Processed Electroencephalogram Monitoring Devices for Assessment of Depth of Anesthesia [J].
Fahy, Brenda G. ;
Chau, Destiny F. .
ANESTHESIA AND ANALGESIA, 2018, 126 (01) :111-117
[9]   Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia [J].
Gan, TJ ;
Glass, PS ;
Windsor, A ;
Payne, F ;
Rosow, C ;
Sebel, P ;
Manberg, P ;
Howell, S ;
Sanderson, I ;
Ray, J ;
Elidrissi, C ;
Wilkes, N ;
Calhoun, P ;
Connors, P ;
Alfille, P ;
Shapiro, L ;
Denman, W ;
Dershwitz, M ;
Clifford, J ;
Embree, P ;
Sigl, J .
ANESTHESIOLOGY, 1997, 87 (04) :808-815
[10]  
Garaud T., 2018, PHD thesis