Indoor Temperature Control of Radiant Ceiling Cooling System Based on Deep Reinforcement Learning Method

被引:3
作者
Tang, Mingwu [1 ]
Wu, Xiaozhou [1 ]
Xu, Jianyi [1 ]
Liu, Jiying [2 ]
Li, Zhengwei [3 ]
Gao, Jie [4 ]
Tian, Zhen [5 ]
机构
[1] Dalian Univ Technol, Sch Civil Engn, Dalian 116024, Peoples R China
[2] Shandong Jianzhu Univ, Dept Thermal Engn, Jinan 250101, Peoples R China
[3] Tongji Univ, Sch Mech & Energy Engn, Shanghai, Peoples R China
[4] Dalian Univ, Coll Civil Engn & Architecture, Dalian 116622, Peoples R China
[5] Hunan Univ, Sch Architecture, Changsha 410082, Peoples R China
基金
中国国家自然科学基金;
关键词
indoor temperature control; radiant ceiling cooling system; on-off control; PID control; deep reinforcement learning; MODEL-PREDICTIVE CONTROL; PERFORMANCE;
D O I
10.3390/buildings13092281
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The radiant ceiling cooling system is widely adopted in modern office buildings as it improves cooling source efficiency and reduces fossil fuel usage and carbon dioxide emissions by utilizing low-grade natural energy. However, the nonlinear behavior and significant inertia of the radiant ceiling cooling system pose challenges for control systems. With advancements in computer technology and artificial intelligence, the deep reinforcement learning (DRL) method shows promise in the operation and control of radiant cooling systems with large inertia. This paper compares the DRL control method with traditional control methods for radiant ceiling cooling systems in two typical office rooms across three different regions. Simulation results demonstrate that with an indoor target temperature of 26 & DEG;C and an allowable fluctuation range of & PLUSMN;1 & DEG;C, the DRL on-off or varied water temperature control satisfies the indoor temperature fluctuation requirements for 80% or 93-99% of the operating time, respectively. In contrast, the traditional on-off or PID variable water temperature control only meets these requirements for approximately 70% or 90-93% of the operating time. Furthermore, compared to traditional on-off control, the DRL control can save energy consumption in the radiant ceiling cooling system by 3.19% to 6.30%, and up to 10.48% compared to PID variable water temperature control. Consequently, the DRL control method exhibits superior performance in terms of minimizing indoor temperature fluctuations and reducing energy consumption in radiant ceiling cooling systems.
引用
收藏
页数:22
相关论文
共 29 条
[1]   Theory and applications of HVAC control systems - A review of model predictive control (MPC) [J].
Afram, Abdul ;
Janabi-Sharifi, Farrokh .
BUILDING AND ENVIRONMENT, 2014, 72 :343-355
[2]  
Aiguo Jin, 2020, Journal of Physics: Conference Series, V1684, DOI [10.1088/1742-6596/1684/1/012140, 10.1088/1742-6596/1684/1/012140]
[3]  
[Anonymous], 2011, Buildings Energy Data Book
[4]  
[Anonymous], 2021, GB 55015-2021
[5]  
[Anonymous], 2015, Design Standard for Energy Efficiency of Public Buildings
[6]   Autonomous HVAC Control, A Reinforcement Learning Approach [J].
Barrett, Enda ;
Linder, Stephen .
MACHINE LEARNING AND KNOWLEDGE DISCOVERY IN DATABASES, PT III, 2015, 9286 :3-19
[7]  
Blad C., 2019, P 29 INT C FLEX AUT
[8]   Model predictive control for energy-efficient optimization of radiant ceiling cooling systems [J].
Chen, Qiong ;
Li, Nan .
BUILDING AND ENVIRONMENT, 2021, 205
[9]  
China Association of Building Energy Efficiency, 2021, BUILD ENERGY EFFIC, V49, P30
[10]   An experimental study of multiple parameter switching control for radiant floor heating systems [J].
Cho, SH ;
Zaheer-Uddin, M .
ENERGY, 1999, 24 (05) :433-444